Ascorbic Acid

Ascorbic Acid

CAS Number62624-30-0
Molecular FormulaC6H8O6
Molecular Weight176.124
InChI KeyCIWBSHSKHKDKBQ-UHFFFAOYSA-N
LogP-2.24
Synonyms
  • Ascorbic acid
  • (5S)-5-[(1R)-1,2-Dihydroxyethyl]-3,4-dihydroxyfuran-2(5H)-one (non-preferred name)
  • 62624-30-0
  • DL-Ascorbic acid
  • (5S)-5-[(1R)-1,2-Dihydroxyethyl]-3,4-dihydroxyfuran-2(5H)-one (non-preferred name)
  • EINECS 263-644-3

Applications:

HPLC Isocratic Method for Analysis of Ascorbic Acid and Sodium Metabisulfite on Primesep SB Column

August 22, 2023

HPLC Method for Analysis of Ascorbic Acid, Sodium metabisulfite on Primesep SB by SIELC Technologies

HPLC Isocratic Method for Analysis of Ascorbic Acid and Sodium Metabisulfite on Primesep SB Column by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of  Ascorbic Acid, Sodium metabisulfite

*The metabisulfite ion (S2O52−) is hydrolyzed to bisulfite (HSO3) in water. Sodium metabisulfite is a white crystalline or powder solid. It has many uses, but some of it’s more prominent are: as the source of SO2 in wine, as a bleaching agent in the production of Coconut cream, and added to anesthetic solutions to prevent oxidation to improve the shelf life of the solution. Ascorbic is found naturally in citrus fruits and many vegetables. As a medication, it is used to prevent or treat low levels of vitamin C, since it is that vitamin. Vitamin C is needed to maintain the health of skin, cartilage, teeth, bone, and blood vessels. Ascorbic Acid and Sodium Metabisulfite can be separated, retained, and analyzed on a Primesep SB mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a phosphoric acid (H3PO4) buffer. This analysis method can be detected in the UV 270 nm.

ColumnPrimesep SB, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O – 50/49.5%
BufferH3PO4 – 0.5%
Flow Rate1.0 ml/min
DetectionUV, 270 nm
Class of Compounds
Acid, Hydrophilic, Ionizable, Disinfectant, Antioxidant, Preservative agent.
Analyzing CompoundsAscorbic Acid, Sodium metabisulfite

Application Column

Primesep SB

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Ascorbic Acid
Sodium metabisulfite

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Ascorbic Acid and Sodium Metabisulfite on Primesep SB Column

August 22, 2023

HPLC Method for Analysis of Ascorbic Acid, Sodium metabisulfite on Primesep SB by SIELC Technologies

HPLC Method for Analysis of Ascorbic Acid and Sodium Metabisulfite on Primesep SB Column by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of  Ascorbic Acid, Sodium metabisulfite

*The metabisulfite ion (S2O52−) is hydrolyzed to bisulfite (HSO3) in water. Sodium metabisulfite is a white crystalline or powder solid. It has many uses, but some of it’s more prominent are: as the source of SO2 in wine, as a bleaching agent in the production of Coconut cream, and added to anesthetic solutions to prevent oxidation to improve the shelf life of the solution. Ascorbic is found naturally in citrus fruits and many vegetables. As a medication, it is used to prevent or treat low levels of vitamin C, since it is that vitamin. Vitamin C is needed to maintain the health of skin, cartilage, teeth, bone, and blood vessels. Ascorbic Acid and Sodium Metabisulfite can be separated, retained, and analyzed on a Primesep SB mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a phosphoric acid (H3PO $) buffer. This analysis method can be detected in the UV 270 nm.

ColumnPrimesep SB, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O
BufferH3PO4
Flow Rate1.0 ml/min
DetectionUV, 270 nm
Class of Compounds
Acid, Hydrophilic, Ionizable, Disinfectant, Antioxidant, Preservative agent.
Analyzing CompoundsAscorbic Acid, Sodium metabisulfite

Application Column

Primesep SB

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Ascorbic Acid
Sodium metabisulfite

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Maleic acid, Ascorbic acid, Nicotinic acid, Fumaric acid and Oxalic acid on BIST™ A+ Column

July 8, 2022

Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies

HPLC Method for Analysis of Organic Acids on BIST™ A+ Column
HPLC Method for Analysis of Maleic acid, Ascorbic acid, Nicotinic acid, Fumaric acid and Oxalic acid on BIST™ A+ Column

High Performance Liquid Chromatography (HPLC) Method for Analysis of  Maleic  acid, Ascorbic acid, Nicotinic acid, Fumaric acid and Oxalic acid

The maleate ion from Maleic acid is a popular ingredient as the maleate salt in several different drugs, including Methergine, Pyrilamine, and Carfenazine, among others. Nicotinic acid, also known as Niacin or Vitamin B3, is an essential nutrient for the human body and is sometimes taken as a treatment for high cholesterol. Aconitic acid is a key intermediary in the citric acid cycle, and is also used a flavoring agent and in the production of rubbers and plastics. Fumaric acid is a popular preservative and food additive with a fruit-like taste. Using SIELC’s newly introduced BIST™ method, a mixture of these organic acids can be separated on a negatively-charged, cation-exchange BIST™ A+ column, contrary to conventional chromatographic wisdom. There are two keys to this retention method: 1) a multi-charged, positive buffer, such as N,N,N’,N’-Tetramethyl-1,3-propanediamine (TMDAP), which acts as a bridge, linking the negatively-charged anion analytes to the negatively-charged column surface and 2) a mobile phase consisting mostly of organic solvent (such as MeCN) to minimize the formation of a solvation layer around the charged analytes. Other positively-charged buffers that can generate BIST™ include Calcium acetate and Magnesium acetate. Using this new and unique analysis method, these organic acids can be separated, retained, and detected through ELSD. This method is also compatible with Mass Spectrometry (LC-MS) and CAD.

https://bist.lc/shop/columns/bist/bist-a-bist/bist-a-column-4-6x150mm-5um-100a-2/

Condition

ColumnBIST™ A+, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN Gradient
BufferTMDAP ( N,N,N’,N’-Tetramethyl-1,3-diaminopropane) phosphate  – 5 mM pH 4.0
Flow Rate1.0 ml/min
DetectionUV 250 nm

Description

Class of CompoundsAcids, Organic acid
Analyzing CompoundsMaleic  acid, Ascorbic acid, Nicotinic acid, Fumaric acid and Oxalic acid

Application Column

BIST A+

BIST™ columns offer a unique and effective way to achieve separations that were traditionally challenging or even impossible with other HPLC columns. With the use of a special mobile phase, these ion exchange columns provide very strong retention for analytes with the same charge polarity as the stationary phase, unlocking new chromatography applications. What makes BIST™ columns stand out is their proprietary surface chemistry, which results in superior selectivity, resolution, and sensitivity. These columns offer a simple, efficient solution for a variety of analytical challenges, making them an excellent choice for researchers and analysts across many different fields. To learn more about the technology that powers BIST™ columns and to explore related applications, check out https://BIST.LC.

Select options
Application Analytes:
Ascorbic Acid
Fumaric Acid
Maleic Acid
Nicotinic Acid/Niacin (3-pyridinecarboxylic acid)
Oxalic Acid
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for the Determination of Acetaminophen, Phenylephrine, and Ascorbic Acid on Primesep S2 Column

October 5, 2021

Separation type: Liquid Chromatography Mixed-mode


HPLC.cloud
View on hplc.cloud

 

High Performance Liquid Chromatography (HPLC) Method for Analysis of Acetaminophen, Phenylephrine, and Ascorbic Acid

Acetaminophen (or paracetamol) is one of the most popular over-the-counter painkillers all over the world (in the US it is best known under the brand name Tylenol). Ascorbic acid (also known as Vitamin C) helps your body build up muscle, cartilage, and other important building blocks in your body. Phenylephrine is a common over-the-counter decongestant, but can also be used for pupil dilation and hemorrhoid treatment. While all of these compounds are available at your local pharmacy, Vitamin C intake can reduce the body’s ability to break down acetaminophen.

All three of these compounds can be measured at low UV. Using a Primsep S normal phase column and a mobile phase consisting of water and acetonitrile (MeCN) with an Ammonium acetate (AmAc) buffer, these three compounds can be separated and UV detected at 270 nm. Varying the buffer concentration changes the order in which phenylephrine and ascorbic acid are retained. This method is compatible with Mass Spectrometry.

 

Condition

Column Primesep S2, 4.6×150 mm, 5 µm, 100A
Mobile Phase Gradient MeCN – 97 to 70%
Buffer Gradient Ammonium Formate pH 3.0 – 10 to 50 mM
Flow Rate 1.0 ml/min
Detection UV 270 nm  MS- compatible mobile phase

Description

Class of Compounds Drug, Acid
Analyzing Compounds Acetaminophen, Phenylephrine, and Ascorbic Acid

 

Application Column

Primesep S2

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Acetaminophen (Paracetamol)
Ascorbic Acid
Phenylephrine
Phenylephrine hydrochloride
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for the Determination of Acetaminophen, Phenylephrine, and Ascorbic Acid on Primesep S Column

October 5, 2021

Separation type: Liquid Chromatography Mixed-mode

 

High Performance Liquid Chromatography (HPLC) Method for Analysis of Acetaminophen, Phenylephrine, and Ascorbic Acid

Condition

Column Primesep S, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O – 80/20%
Buffer Ammonium acetate pH 5.0
Flow Rate 1.0 ml/min
Detection UV 270nm  MS- compatible mobile phase

Description

Class of Compounds Drug
Analyzing Compounds Acetaminophen, Phenylephrine, and Ascorbic Acid

Application Column

Primesep S

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Acetaminophen (Paracetamol)
Ascorbic Acid
Phenylephrine
Phenylephrine hydrochloride
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Determination of Ascorbic Acid in Strawberry Juice

May 6, 2019


FlipLC™ is an alternative method to avoid the interference of most of the contaminants by the use of an isolation column and a high pressure switching valve before the separation column. This method allows sample cleaning and analyte separation in one automated process. The isolation column and the separation column should have orthogonal retention characteristics to operate efficiently in this setup. Mixed-mode columns with reverse phase and ion-exchange characteristics were used in this analysis.

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options

Primesep SB

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ascorbic Acid
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Ascorbic Acid and Sodium Metabisulfite on Newcrom BH Column

February 28, 2018

HPLC Method for Analysis of Ascorbic Acid, Sodium metabisulfite, Sodium bisulfite on Newcrom BH by SIELC Technologies


HPLC.cloud
View on hplc.cloud

*The metabisulfite ion (S2O52−) is hydrolyzed to bisulfite (HSO3) in water. Sodium metabisulfite is a white crystalline or powder solid. It has many uses, but some of it’s more prominent are: as the source of SO2 in wine, as a bleaching agent in the production of Coconut cream, and added to anesthetic solutions to prevent oxidation to improve the shelf life of the solution. Ascorbic is found naturally in citrus fruits and many vegetables. As a medication, it is used to prevent or treat low levels of vitamin C, since it is that vitamin. Vitamin C is needed to maintain the health of skin, cartilage, teeth, bone, and blood vessels. Ascorbic Acid and Sodium Metabisulfite can be separated, retained, and analyzed on a Newcrom BHmixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a phosphoric acid (H3PO $) buffer. This analysis method can be detected in the UV 275 nm.

Column(Column variation not found)
Mobile PhaseMeCN/H2O – 50/50%
BufferH3PO4 – 0.5%
Flow Rate0.5 ml/min
DetectionUV 275nm
Class of CompoundsAcid
Analyzing CompoundsAscorbic Acid, Sodium metabisulfite, Sodium bisulfite

High Performance Liquid Chromatography (HPLC) Method for Analysis of  Ascorbic Acid, Sodium metabisulfite, Sodium bisulfite

Application Column

Newcrom BH

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options

Primesep SB

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ascorbic Acid
Sodium bisulfite
Sodium metabisulfite

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Organic Acids in HILIC and Anion-Exclusion Mode on Primesep S2 Column

July 14, 2011

Organic acids were separated on a HILIC/cation-exchange column in HILIC/anion-exclusion mode. This column can be used for analysis of polar compounds in HILIC mode. If compounds are ionizable, additional mode of interaction can be added (cation-exchange or anion-exclusion).

Condition

Column Primesep S2, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O – 85/15%
Buffer AmAc pH 5.0 15 mM
Flow Rate 1.0 ml/min
Detection ELSD, 50C UV 250 nm

 

Description

Class of Compounds
Nucleosides,  Hydrophilic, Ionizable
Analyzing Compounds Toluenesulfonic acid, Naphthalenedisulfonic acid, 3.5 DHBA, Ascorbic acid,

 

Application Column

Primesep S2

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
1,5-Naphthalenedisulfonic Acid
3,5-Dihydroxybenzoic Acid
Ascorbic Acid
Organic Acids
p-Toluenesulfonic Acid (PTSA)

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Ascorbic and Dehydroascorbic Acids

November 21, 2010


Ascorbic acid is a vital vitamin for humans. It also serves as an antioxidant. Dehydroascorbic acid is an oxidation product of ascorbic acid. Both molecules are very polar, and cannot be retained by reverse-phase mechanism. Generic method for HPLC separation of ascorbic and dehydroascorbic acid was developed on a Primesep SB mixed-mode HPLC column. Both compounds are well separated and produce excellent peak shape. Method can be used for analysis of both compounds in biofluids. Proteins from biofluids will not retain due to repulsion effect of the stationary phase. Compounds can be monitored by common detection techniques like UV, ELSD, CAD, and LC/MS.

Condition

Column Primesep  SB , 4.6×50 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer Formic Acid
Flow Rate 1.0 ml/min
Detection ELSD

 

Description

Class of Compounds
Acid, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Ascorbic acid (Vitamin C), Dehydroascorbic acid

Application Column

Primesep SB

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ascorbic Acid
Dehydroascorbic Acid

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Analysis of Ascorbic Acid, Retinol (Vitamin A) and Vitamin E acetate in ACE Serum Active Ingredients

October 14, 2010


Mixed-mode HPLC columns allow for separation of compounds with drastically different properties. In this application, highly hydrophilic ascorbic acid is retained and separated from highly hydrophobic retinol (Vitamin A) and Vitamin E Acetate. Ascorbic acid is retained by anion-exchange mechanism and hydrophobic compounds are retained by reversed-phase mechanism. Compounds are monitored by UV detection. Mobile phase is compatible with LC/MS and method can be used to monitor basic and acidic compounds in bio-fluids (serum, blood, urine, saliva, etc.)
Retinol (Vitamin A)  and Vitamin E Acetate

Condition

Column Primesep  SB , 3.0×50 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer Acetic Acid
Flow Rate 0.5 ml/min
Detection UV 270, 325

 

Description

Class of Compounds
Acid, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Ascorbic acid (Vitamin C), Retinol (Vitamin A) and Vitamin E Acetate

Application Column

Primesep SB

Column Diameter: 3.2 mm
Column Length: 50 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Ascorbic Acid
Retinol (Vitamin A)
Vitamin E Acetate

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Analysis of Active Drug in a Formulation

October 4, 2010


HPLC method for separation of active ingredients of drug/supplemental composition was developed on an Obelisc R trimodal HPLC column. Compounds are retained by combination of reversed-phase, cation-exchange and anion-exchange mechanisms. Compounds are well separated, and method can be used for quantitation of pyridoxine, ascorbic acid, niacinamide, pantothenic acid, caffeine and riboflavin in a mixture or as separate compounds in various complex mixtures. Various detection techniques can be applied for quantitation (ELSD, UV, LC/MS, Corona). This HPLC method can be adopted as general approach for analysis of active drug components in various formulations.

Condition

Column Obelisc R , 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O  -5/95%
Buffer NaHPO4 pH 3.0 – 30 mM
Flow Rate 1.0 ml/min
Detection UV, 210 nm

 

Description

Class of Compounds
Drug, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Pyridoxine, Ascorbic acid, Niacinamide, Pantothenic acid, Caffeine, Riboflavin

Application Column

Obelisc R

SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.

Select options
Application Analytes:

Ascorbic Acid
Caffeine
Niacinamide
Pantothenic Acid
Vitamin B6 (Pyridoxine)

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HILIC Separation of Common Preservatives – Citric Acid, Ascorbic Acid and EDTA

July 16, 2009

Citric acid, ascorbic acid, and EDTA are commonly used in food and pharmaceutical industry as preservatives. These compounds are very polar in nature. They are weak organic acids with limited UV activity. Retention and separation is achieved on HILIC mixed-mode Obelisc N column. All three compounds are retained by combination of strong HILIC and strong anion-exchange mechanisms. Separation can be monitored by ELSD, LC/MS, UV or Corona CAD. In contrast to other HILIC column, Obelisc N has two ionizable groups basic and acidic which provide ion-exchange interaction in addition to hydrophilic interaction. This allows to use less acetonitrile for HILIC separation.

Condition

Column Obelisc N , 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer AmAc pH 4.0
Flow Rate 1.0 ml/min
Detection ELSD

 

Description

Class of Compounds
Acid, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Citric acid, ascorbic acid and EDTA

Application Column

Obelisc N

SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.

Select options
Application Analytes:
Ascorbic Acid
EDTA (Ethylenediaminetetraacetic Acid)
Vitamin C

Application Detection:
ELSD Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Vitamin C, Vitamin Group B, and Related Impurities

August 22, 2008

Vitamin C (ascorbic acid) and Vitamins Group B are separated on Obelisc N mixed-mode column. Method can be used in quantitation and determination of polar vitamins in various formulations and dietary supplements. HPLC method can be based on UV, Evaporative Light Scattering Detection (ESLD), RI or MS detection. Effect of sample matrix can be eliminated by changing mobile phase conditions. Buffer concentration, buffer pH and amount of ACN will affect every vitamin differently due to difference in polar and ionic properties.

Condition

Column Obelisc N , 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer AmAc pH 5.0
Flow Rate 1.0 ml/min
Detection UV, 250 nm

 

Description

Class of Compounds
Drug, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Pyridoxine, Ascorbic acid, Niacinamide, Pantothenic acid, Caffeine, Riboflavin, Barbituric Acid,  3- Aminopyrine

Application Column

Obelisc N

SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.

Select options
Application Analytes:

3-Aminopyridine
4-Aminopyridine/Fampridine
Ascorbic Acid
Barbituric Acid
Isonicotinic Acid
Nicotinic Acid/Niacin (3-pyridinecarboxylic acid)
Vitamin B2 (Riboflavin)
Vitamin B6 (Pyridoxine)

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Organic Acids in HILIC Mode on Primesep N Column

December 6, 2007

Ascorbic, methylmalonic and succinic are weak organic acids. Retention of these three acids is achieved on Primesep N column in HILIC mode using acetonitrile/water and ammonium acetate. Compounds are monitored by ELSD. Method can be used for determination of ascorbic acid (Vitamin C), methylmalonic acid and succinic acid in various matrices. Other polar organic acids can be analyzed on this HILIC column.

Condition

Column Primesep  N , 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer AmAc
Flow Rate 1.0 ml/min
Detection ELSD

 

Description

Class of Compounds
Acid, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Ascorbic acid (Vitamin C), Methylmalonic acid,  Succinic acid

Application Column

Primesep N

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ascorbic Acid
Methylmalonic Acid
Organic Acids
Succinic Acid

Application Detection:
ELSD Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Two Vitamins: Different Polarity – Isocratic Methods

May 13, 2004

Primesep B and B2 columns separate Vitamins C (ascorbic acid) and B2 (riboflavin) with tunable selectivity. Peak order reversal is exhibited on these two columns with the same mobile phases due to their different polarity. The HPLC separation uses a mobile phase of water, acetonitrile (MeCN, ACN) and either formic or acetic acid (HOAc) with UV detection at 250 nm.

Condition

Column Primesep B, Primesep B2 , 3.2×50 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer Formic Acid, Acetic Acid
Flow Rate 0.5 ml/min
Detection UV, 250 nm

 

Description

Class of Compounds
Drug, Vitamin B₆, Hydrophobic, Ionizable
Analyzing Compounds Vitamins C (ascorbic acid) and B2 (riboflavin)

Application Column

Primesep B

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options

Primesep B2

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:

Ascorbic Acid
Vitamin B2 (Riboflavin)
Vitamin C

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.