CAS Number | 61-90-5 |
---|---|
Molecular Formula | C6H13NO2 |
Molecular Weight | 131.175 |
InChI Key | ROHFNLRQFUQHCH-YFKPBYRVSA-N |
LogP | -1.52 |
Synonyms |
|
Essential amino acids cannot be made by the body. As a result, they must come from food.
The 9 essential amino acids are: histidine, isoleucine, leucine, lysine, methionine, phenylalanine, threonine, tryptophan, and valine.
Column | Newcrom AH, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 5% |
Buffer | Gradient Formic Acid – 3-9%, 20 min |
Flow Rate | 1.0 ml/min |
Detection | CAD |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | L-Threonine (Thr/T), L-Valine (Val/V), DL-Methionine (Met/M), L-Isoleucine (Ile/I), L-Leucine (Leu/L), L-Phenylalanine (Phe/F), L-Histidine (His/H), Lysine (Lys/K) , L- Tryptophan (Trp/W), L-Arginine (Arg/R) |
The Newcrom columns are a family of reverse phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse phase column with low silanol activity.
Select optionsColumn | Primesep 100, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 5/95% |
Buffer | AmFM pH 3.0 – 30 mM |
Flow Rate | 1.0 ml/min |
Detection | CAD (Corona) MS- compatible mobile phase |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | Allo-Isoleucine, Isoleucine, Leucine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsBoth β-hydroxy-β-methylbutyric acid (HMB) and 2-hydroxyisocaproic acid (HICA) are metabolites of the
essential dietary branched chain amino acid leucine.
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 5%, 3 min hold, Gradient MeCN 5-30% 12 min |
Buffer | H2SO4 – 0.05 % 3 min hold, GradientH2SO4 0.05-3% 12 min |
Flow Rate | 1.0 ml/min |
Detection | UV, 210 nm |
Class of Compounds |
Acid, Hydrophilic, Ionizable, Normal human metabolite, Dietary supplement, Essential amino acid, Branched-chain amino acid (BCAA) |
Analyzing Compounds | β‑Hydroxy-β-methylbutyric (HMB), 2-Hydroxyisocaproic Acid (HICA), Leucine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options
Column | Primesep 100, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 35/65% |
Buffer | H2SO4 0.05% 12 min hold, gradient 0.05-0.20, 13 min |
Flow Rate | 1.0 ml/min |
Detection | UV, 200 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | L-Asparagine (Asn/N), L-Threonine (Thr/T), L-Cysteine (Cys/C), L-Proline (Pro/P), L-Valine (Val/V), DL-Methionine (Met/M), L-Isoleucine (Ile/I), L-Leucine (Leu/L), L-Phenylalanine (Phe/F), L- Tryptophan (Trp/W), L-Histidine (His/H), L-Arginine (Arg/R) |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options
Application Notes: Amino acids are polar ionic compounds which are not retained on reversed-phase column without ion-pairing reagent. In our application, lysine and arginine can be separated from other amino acids. Amino acids with a pH between 3 and 5 and with one basic and one acidic group become very polar. Therefore these amino acids don’t have strong ion-exchange interaction with Primesep C stationary phase. Amino acids with two amino groups still carry positive net charge and can interact with stationary phase by cations-exchange mechanism. pH variation of the mobile phase can be an effective tool to adjust selectivity of separation for zwitter-ionic, basic and acidic compounds. This method can be used for separation of mono-charged compounds from compounds having an extra charge.
Application Columns: Primesep C
Application compounds: Aspartic acid, Glutamic acid, Aspargine, Glycine, Proline, Alanine, Phenylalanine, Tyrosine, Leucine, Lysine, Arginine
Detection technique: UV, LC/MS, ELSD/CAD
Column | Primesep C, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 15% |
Buffer | AmAc pH 5.0- 15 mM |
Flow Rate | 1.0 ml/min |
Detection | ELSD |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements |
Analyzing Compounds | Aspartic acid, Glutamic acid, Aspargine, Glycine, Proline, Alanine, Phenylalanine, Tyrosine, Leucine, Lysine, Arginine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsEssential and non-essential amino acids can be retained and separated in zero-organic mode on Primesep mixed-mode HPLC columns. Zero-organic mode is required to monitor isotopes of carbon. Amino acids are retained by combination of reversed-phase and cation-exchange mechanisms. At lower pH, some of the amino acids are more hydrophobic. Buffer pH will affect ionization state of amino acids, and at higher pH (above 2.5), the amino acids will be less hydrophobic and retentive in zero-organic mode. Amino acids can be monitored by low UV. Method can be used in archeological research for analysis of various molecules where presence of organic component of the mobile phase interferes with analysis.
Column | Primesep 200, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O |
Buffer | Na2HPO4 |
Flow Rate | 1.0 ml/min |
Detection | UV 210 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements |
Analyzing Compounds | Valine, Leucyne, Isoleycine, Tyrosine, Phenylalanine, Histidine, Lysine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsGlutamine, valine, isoleucine, and leucine are baseline resolved in a dietary supplement with a mobile phase of acetonitrile, water, and sulfuric acid with ultraviolet (UV) detection at 210 nm on a Primesep 100 column. Increasing the sulfuric acid concentration allows elution of arginine. Primesep 100 separates underivatized amino acids and amines by combining reversed-phase and ion-exchange mechanisms. The HPLC separation uses a mobile phase of water, acetonitrile (MeCN, ACN), and sulfuric acid with ultraviolet (UV) detection at 210 nm.
Column | Primesep 100, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 30/70% |
Buffer | H2SO4 |
Flow Rate | 1.0 ml/min |
Detection | UV, 210 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | Arginine, Glutamine, L-Valine (Val/V), L-Isoleucine (Ile/I), L-Leucine (Leu/L) |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsAdding on to the previous HPLC separation of amino acids using Bufferless Ion Separation (BLIS) Chromatography; here we have additional amino acids separated on Primesep 200 column using only water and acetonitrile (MeCN, ACN) in the mobile phase. Primesep 200 is a reverse-phase (RP) column with weak acidic ion-pairing groups embedded. With no buffer present in the mobile phase, detection can be achieved with UV, mass spectrometry (MS), evaporative light scattering detection (ELSD).
Column | Primesep 200, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | No |
Flow Rate | 1.0 ml/min |
Detection | UV, 195 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | Aspartic acid, Alanine, Valine, Methionine, Leucine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options© SIELC Technologies. 2002 - 2023
Address: 804 Seton Court, Wheeling, IL USA 60090
Tel: (847) 229-2629 | Fax: (847) 655-6079
Sales, Refund and Returns Policy
Email: mail@sielc.com | Sitemap