CAS Number | 72-19-5 |
---|---|
Molecular Formula | C4H9NO3 |
Molecular Weight | 119.12 |
InChI Key | AYFVYJQAPQTCCC-GBXIJSLDSA-N |
LogP | -2.9 |
Synonyms |
|
Applications:
HPLC Separation of Mixture of Nine Essential Amino acids and Arginine on Newcrom AH Column
September 25, 2020
Essential amino acids cannot be made by the body. As a result, they must come from food.
The 9 essential amino acids are: histidine, isoleucine, leucine, lysine, methionine, phenylalanine, threonine, tryptophan, and valine.
Column | Newcrom AH, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 5% |
Buffer | Gradient Formic Acid – 3-9%, 20 min |
Flow Rate | 1.0 ml/min |
Detection | CAD |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | L-Threonine (Thr/T), L-Valine (Val/V), DL-Methionine (Met/M), L-Isoleucine (Ile/I), L-Leucine (Leu/L), L-Phenylalanine (Phe/F), L-Histidine (His/H), Lysine (Lys/K) , L- Tryptophan (Trp/W), L-Arginine (Arg/R) |
Application Column
Newcrom AH
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select optionsHistidine
Isoleucine
L-Threonine
Leucine
Lysine
Methionine
Phenylalanine
Tryptophan
Valine
HPLC Separation of Mixture of 12 Amino Acids on Primesep 100 Column
March 11, 2019
Column | Primesep 100, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 35/65% |
Buffer | H2SO4 0.05% 12 min hold, gradient 0.05-0.20, 13 min |
Flow Rate | 1.0 ml/min |
Detection | UV, 200 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | L-Asparagine (Asn/N), L-Threonine (Thr/T), L-Cysteine (Cys/C), L-Proline (Pro/P), L-Valine (Val/V), DL-Methionine (Met/M), L-Isoleucine (Ile/I), L-Leucine (Leu/L), L-Phenylalanine (Phe/F), L- Tryptophan (Trp/W), L-Histidine (His/H), L-Arginine (Arg/R) |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsArginine
Asparagine
Cysteine
D-Isoleucine
D-Leucine
D-Valine
DL-Isoleucine
Histidine
Isoleucine
L-Cysteine
L-Methionine
L-Threonine
Leucine
Methionine
Phenylalanine
Proline
Tryptophan
Valine
HPLC Separation of Mixture of Essential Amino Acids on Primesep 100 Column
March 11, 2019
Column | Primesep 100, 4.6×250 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 25/75% |
Buffer | Gradient H2SO4 0.05-0.2% 25 min |
Flow Rate | 1.0 ml/min |
Detection | UV, 200 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements, Amino acid |
Analyzing Compounds | L-Threonine (Thr/T), L-Valine (Val/V), DL-Methionine (Met/M), L-Isoleucine (Ile/I), L-Leucine (Leu/L), L-Phenylalanine (Phe/F), L-Histidine (His/H), L- Tryptophan (Trp/W) |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsD-Isoleucine
D-Leucine
D-Valine
DL-Isoleucine
Histidine
Isoleucine
L-Histidine hydrochloride monohydrate
L-Isoleucine
L-Methionine
L-Threonine
Methionine
Phenylalanine
Tryptophan
Valine