Methylparaben sodium

Methylparaben sodium structural formula

CAS Number5026-62-0
Molecular FormulaC8H7NaO3
Molecular Weight174.131
InChI KeyPESXGULMKCKJCC-UHFFFAOYSA-M
LogP1.24
Synonyms
  • Methylparaben sodium
  • Sodium 4-(methoxycarbonyl)phenolate
  • Benzoic acid, 4-hydroxy-, methyl ester, sodium salt (1:1)
  • 5026-62-0
  • Benzoic acid, 4-hydroxy-, methyl ester, sodium salt
  • 4-(Methoxycarbonyl)phenolate de sodium
  • 4-(metoxicarbonil)fenolato de sodio
  • 4-HYDROXYBENZOESAEURE-METHYLESTER-NA-SALZ
  • 4-Hydroxybenzoic acid methyl ester sodium salt
  • BENZOATE, 4-OXIDE-, METHYL, SODIUM
  • Benzoic acid, 4-hydroxy-, methyl ester, sodium salt (1:1)
  • Benzoic acid, p-hydroxy-, methyl ester, sodium salt
  • Bonomold OMNa
  • Methyl 4-hydroxybenzoate sodium salt
  • Methyl p-hydroxybenzoate sodium salt
  • Natrium-4-(methoxycarbonyl)phenolat
  • p-Hydroxybenzoic acid methyl ester sodium salt
  • Preserval MS
  • sodium 4-(methoxycarbonyl)phenolate
  • Sodium 4-(methoxycarbonyl)phenoxide
  • Sodium 4-carbomethoxyphenolate
  • Sodium methyl 4-hydroxybenzoate
  • Sodium methyl p-hydroxybenzoate
  • Sodium methyl-4-hydroxybenzoate
  • Sodium methylparaben
  • Sodium p-methoxycarbonylphenoxide
  • Sodium, (p-carboxyphenoxy)-, methyl ester
  • Solparol
  • EINECS 225-714-1
  • Methyl p-hydroxybenzoate, sodium salt
  • UNII-CR6K9C2NHK

Applications:

HPLC Analysis of Paraben Preservatives on Newcrom AH Column

October 29, 2020

HPLC Method for Ethylparaben, Methylparaben sodium, Propylparaben sodium, Methylparaben, Parabens, Propylparaben on Newcrom AH by SIELC Technologies

 

High Performance Liquid Chromatography (HPLC) Method for Analysis of Ethylparaben, Methylparaben sodium, Propylparaben sodium, Methylparaben, Parabens, Propylparaben.

Methylparaben, also known as Methyl 4-hydroxybenzoate, is a paraben with the chemical formula C8H8O3. It is used as a preservative in food, cosmetics, and pharmaceuticals as it is said to have antimicrobial and antifungal properties. It is considered safe for use in low concentrations, but it may cause irritation or contact dermatitis in rare cases and for those who are allergic.

Ethylparaben is an ethyl ester of p-hydroxybenzoic acid with the chemical formula C9H10O3. It is used as a preservative in food, cosmetics, and pharmaceuticals due to it’s antimicrobial and antifungal properties. There are ongoing debates in regards to it’s safety as it relates to human consumption,

Propylparaben is a n-propyl ester with the chemical formula C10H12O3. It is used as a preservative in food, cosmetics, and personal care products due to it’s antimicrobial properties. Studies show that it absorbs through the skin and remains in the body, leading to the European Union banning it. California had banned it for use in food, but not in other uses.

You can find detailed UV spectra of Methylparaben and information about its various lambda maxima by visiting the following link.

You can find detailed UV spectra of Ethylparaben and information about its various lambda maxima by visiting the following link.

You can find detailed UV spectra of Propylparaben and information about its various lambda maxima by visiting the following link.

Ethylparaben, Methylparaben sodium, Propylparaben sodium, Methylparaben, Parabens, Propylparaben can be retained and analyzed using the Newcrom AH stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a sulfuric acid buffer. Detection is performed using UV.

Condition

Column Newcrom AH, 3.2 x 100 mm, 5 µm, 100 A, dual ended
Mobile Phase MeCN/H2O – 30/70%
Buffer H2SO4 – 0.1%
Flow Rate 0.5 ml/min
Detection UV, 270 nm

 

Description

Class of Compounds
Preservatives,  Hydrophobic
Analyzing Compounds Ethylparaben, Methylparaben sodium, Propylparaben sodium, Methylparaben, Parabens, Propylparaben

 

Application Column

Newcrom AH

Column Diameter: 3.2 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Ethylparaben
Methylparaben
Methylparaben sodium
Parabens
Propylparaben
Propylparaben sodium

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Determination of EDTA, Phenoxyethanol and Methylparaben in Facial Cleanser on Newcrom BH

August 25, 2020

HPLC Method for EDTA (Ethylenediaminetetraacetic Acid), Methylparaben, Methylparaben sodium, 2-Phenoxyethanol on Newcrom BH by SIELC Technologies

 

High Performance Liquid Chromatography (HPLC) Method for Analysis of EDTA (Ethylenediaminetetraacetic Acid), Methylparaben, Methylparaben sodium, 2-Phenoxyethanol.

Ethylenediaminetetraacetic acid (EDTA) is a synthetic amino acid with the chemical formula C10H16N2O8. It is typically used in industry to sequester metal ions, which helps prevent change of colors in textiles and uneven bleaching in paper. Due to it being a chelator, it is also used to soften water during laundry, remove hydrogen sulfide from gas streams, as well as treat mercury and lead poisoning.

Phenoxyethanol is a synthetic compound with the chemical formula C8H10O2. It is said to have antimicrobial and preservative properties, leading to wide use of it in cosmetics, medicine, and biocides. It is considered safe in the US and Europe at limited concentrations.

Methylparaben, also known as Methyl 4-hydroxybenzoate, is a paraben with the chemical formula C8H8O3. It is used as a preservative in food, cosmetics, and pharmaceuticals as it is said to have antimicrobial and antifungal properties. It is considered safe for use in low concentrations, but it may cause irritation or contact dermatitis in rare cases and for those who are allergic.

You can find detailed UV spectra of EDTA + Fe complex and information about its various lambda maxima by visiting the following link.

You can find detailed UV spectra of Methylparaben and information about its various lambda maxima by visiting the following link.

EDTA (Ethylenediaminetetraacetic Acid), Methylparaben, Methylparaben sodium, 2-Phenoxyethanol can be retained and analyzed using the Newcrom BH stationary phase column. The analysis utilizes a gradient method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a sulfuric acid buffer. Detection is performed using UV.

Condition

Column Newcrom BH, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile Phase Gradient MeCN – 2- 70%, 10 min
Buffer H2SO4 – 0.1%
Flow Rate 1.0 ml/min
Detection UV 260nm

Description

Class of Compounds Acid, Hydrophilic, Preservatives
Analyzing Compounds EDTA (Ethylenediaminetetraacetic Acid), Methylparaben, Methylparaben sodium, 2-Phenoxyethanol

 

Application Column

Newcrom BH

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
2-Phenoxyethanol
EDTA (Ethylenediaminetetraacetic Acid)
Methylparaben
Methylparaben sodium

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Mixture of Carbocisteine, Methylparaben & Propylparaben on Primesep 100 Column

July 31, 2019

HPLC Method for Carbocisteine, Methylparaben sodium, Propylparaben sodium, Propylparaben, Methylparaben on Primesep 100 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Carbocisteine, Methylparaben sodium, Propylparaben sodium, Propylparaben, Methylparaben.

Carbocysteine is a medication that reduces the viscosity of mucus making it easier to cough up. Methylparaben and propylparaben are used as preservatives in cosmetics, pharmaceuticals and food. They can be separated in HPLC on a Primesep 100 mixed-mode column by both hydrophobic and ionic properties present on the stationary phase. The analytical method uses acetonitrile (ACN) gradient and water with sulfuric acid (H2SO4) as buffer and UV detected at 200nm.

Condition

Column Primesep 100
Mobile Phase Gradient MeCN  – 2-50%, 20 min
Buffer H2SO4 – 0.05 %
Flow Rate 1.0 ml/min
Detection UV, 200 nm

 

Description

Class of Compounds
Drug,  Acid, Hydrophilic, Ionizable, Carboxylic acid, Carbocyclic, Benzoate, Hydroxy Acid, Amino Acid, Hydroxybenzoate, Phenol
Analyzing Compounds Carbocisteine, Methylparaben sodium, Propylparaben sodium, Propylparaben, Methylparaben

 

Application Column

Primesep 100

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Carbocisteine
Methylparaben
Methylparaben sodium
Propylparaben
Propylparaben sodium

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of Methylparaben sodium on Newcrom R1 HPLC column

February 16, 2018
Separation of Methylparaben sodium on Newcrom C18 HPLC column

Methylparaben sodium can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Methylparaben sodium
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us before ordering the column as there may be a more suitable column alternative by either e-mail: support@sielc.com or by phone: 847-229-2629.