CAS Number | 35285-69-9 |
---|---|
Molecular Formula | C10H11NaO3 |
Molecular Weight | 202.185 |
InChI Key | IXMINYBUNCWGER-UHFFFAOYSA-M |
LogP | 2.17 |
Synonyms |
|
Applications:
HPLC Analysis of Paraben Preservatives on Newcrom AH Column
October 29, 2020
Column | Newcrom AH, 3.2×100 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 30/70% |
Buffer | H2SO4 – 0.1% |
Flow Rate | 0.5 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Preservatives, Hydrophobic |
Analyzing Compounds | Methyl Paraben, Ethyl Paraben, Propyl Paraben |
Application Column
Newcrom AH
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select optionsMethylparaben
Methylparaben sodium
Parabens
Propylparaben
Propylparaben sodium
HPLC Separation of Mixture of Carbocisteine, Methylparaben & Propylparaben on Primesep 100 Column
July 31, 2019
Carbocysteine is a medication that reduces the viscosity of mucus making it easier to cough up. Methylparaben and propylparaben are used as preservatives in cosmetics, pharmaceuticals and food. They can be separated in HPLC on a Primesep 100 mixed-mode column by both hydrophobic and ionic properties present on the stationary phase. The analytical method uses acetonitrile (ACN) gradient and water with sulfuric acid (H2SO4) as buffer and UV detected at 200nm.
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 2-50%, 20 min |
Buffer | H2SO4 – 0.05 % |
Flow Rate | 1.0 ml/min |
Detection | UV, 200 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Carboxylic acid, Carbocyclic, Benzoate, Hydroxy Acid, Amino Acid, Hydroxybenzoate, Phenol |
Analyzing Compounds | Carbocisteine, Methylparaben, Propylparaben |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsMethylparaben
Methylparaben sodium
Propylparaben
Propylparaben sodium
Separation of Propylparaben sodium on Newcrom R1 HPLC column
February 16, 2018
Propylparaben sodium can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options