| CAS Number | 57-62-5 |
|---|---|
| Molecular Formula | C22H23ClN2O8 |
| Molecular Weight | 478.881 |
| InChI Key | CYDMQBQPVICBEU-XRNKAMNCSA-N |
| LogP | -0.620 |
| Synonyms |
|
Applications:
HPLC Method for Analysis of Chlortetracycline on Primesep 100 Column
November 12, 2026
HPLC Method for Chlortetracycline on Primesep 100 by SIELC Technologies

Chlortetracycline is a tetracycline antibiotic with the formula C22H23ClN2O8. It is used primarily in combination with triamcinolone to treat infected allergic dermatitis. It is used widely in veterinary medicine to treat conjunctivitis, infected wounds, and respiratory tract infections.
Chlortetracycline can be retained, and analyzed using a Primesep 100 mixed-mode stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water, acetonitrile (MeCN), and H2SO4 as a buffer. Detection is carried out using UV
| Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 50/50% |
| Buffer | H2SO4 – 0.1% |
| Flow Rate | 1 ml/min |
| Detection | UV 268 nm |
| LOD* | 60 ppb |
| Class of Compounds | Medication |
| Analyzing Compounds | Chlortetracycline |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Separation of Antibiotics in Mixed-mode chromatography
May 11, 2015

A complex mixture of sulphonamide, macrolide, tetracycline and fluoroquinolone antibiotics were separated in one run using mixed-mode chromatography with LC/MS -compatible conditions. All compounds are separated based on reversed-phase and/or ion-exchange mechanism. Method can be used for analysis of various classes of antibiotics and related impurities in different sample matrices (blood, urine, soil, waste water).
| Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
| Mobile Phase | Gradient MeCN – 0-25%, 6 min, 25-70% 14 min |
| Buffer | Gradient Formic Acid – 0.05%-0.3%, 10 min, 14 min hold |
| Flow Rate | 1.0 ml/min |
| Detection | UV, 270 nm |
| Class of Compounds |
Antibiotic, Drug, Hydrophobic, Ionizable |
| Analyzing Compounds | Sulphanilamide, Sulphaguanidine, Oxytetracycline, Marbofloxacin, Sulphadiazine, Chlortetracycline, Nofloxacin, Spiramycin, Cefalonium, Tylosin, Josamycin, Sulphamethoxazole, Dapsone, Sulphaquinoxalline, Flumequine |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsChlortetracycline
Dapsone
Flumequine
Josamycin
Marbofloxacin
Norfloxacin
Oxytetracycline
Spiramycin
Sulfamethoxazole
Sulfonamides
Sulphadiazine
Sulphaguanidine
Sulphanilamide
Sulphaquinoxaline
Tetracycline
Tylosin
UV Detection
Separation of Oxytetracycline and Chlortetracycline in Mixed-Mode
May 11, 2015

Oxytetracycline and chlortetracycline are polar compounds related to broad-spectrum of tetracycline group of antibiotics. Slight hydrophobicity and presence of the basic group in both compounds allow to employ mixed-mode reversed-phase cation-exchange mechanism for separation of these compounds. Method can be used for analysis of antibiotics and related impurities with LC/MS compatible conditions.
| Column | Primesep 100, 4.6×150 mm, 3 µm, 100A |
| Mobile Phase | MeCN/H2O |
| Buffer | H2SO4 |
| Flow Rate | 1.0 ml/min |
| Detection | UV, 250 nm |
| Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable |
| Analyzing Compounds | Oxytetracycline, Chlortetracycline |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsOxytetracycline
UV Detection