CAS Number | 151-21-3 |
---|---|
Molecular Formula | C12H25NaO4S |
Molecular Weight | 288.380 |
InChI Key | DBMJMQXJHONAFJ-UHFFFAOYSA-M |
LogP | 1.60 |
Synonyms |
|
Applications:
HPLC Determination of Sodium Dodecyl Sulfate on Newcrom BH and Newcrom B Columns
June 5, 2024
Sodium dodecyl sulfate, or sodium lauryl sulfate, is a surfactant used in cleaning and hygienic products. It has a twelve carbon hydrophobic tail attached to a polar sulfate. Dodecyl sulfate can be retained on Newcrom BH column in under 10 minutes with an MS-compatible mobile phase.
Column | Newcrom B, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 70/30% |
Buffer | AmFm pH 3.0 – 60 mM |
Flow Rate | 1.0 ml/min |
Detection | CAD (Corona) MS- compatible mobile phase |
Class of Compounds |
Hydrophobic, Base, Ionizable, Anionic surfactant |
Analyzing Compounds | Sodium Dodecyl Sulfate |
Application Column
Newcrom B
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Method for Separation of Hydrophobic, Cationic and Anionic Surfactants on Newcrom BH Column
July 10, 2023
HPLC Method for Separation of Hydrophobic, Cationic and Anionic Surfactants on Newcrom BH by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
Surfactants, also known as surface-active agents, are compounds that lower the surface tension (or interfacial tension) between two liquids or between a liquid and a solid. Surfactants may act as detergents, wetting agents, emulsifiers, foaming agents, or dispersants.
They are often classified according to the charge of the polar head group:
Anionic Surfactants: These surfactants have a negative charge on their polar head group. Common examples include soap, sodium laureth sulfate, and sodium lauryl sulfate. They are commonly used in detergents and shampoos due to their ability to emulsify oils and hold dirt in suspension, so it can be rinsed away.
Cationic Surfactants: These surfactants have a positive charge on their polar head group. Examples include cetyltrimethylammonium bromide (CTAB) and benzalkonium chloride. These are often used as antiseptics and can also be found in hair conditioners because they reduce static cling.
Nonionic Surfactants: These surfactants have no charge on their polar head group. Examples include alcohol ethoxylates, nonylphenol ethoxylates, and polysorbates. Nonionic surfactants are often used in laundry and dishwasher detergents.
All compounds can be retained, separated, and analyzed using a reverse-phase Newcrom BH, 4.6 x 150 mm, 5 µm, 100 A column. The mobile phase for this method consists of water, acetonitrile (MeCN), and Ammonium formate, which serves as a buffer. This analytical method can be detected with an Evaporative Light Scattering Detector (ELSD) or any other evaporative detection method (CAD, ESI-MS).
High Performance Liquid Chromatography (HPLC) Method for Analysis of Benzalkonium chloride, Cetylpyridinium Chloride, 1-Pentanesulfonic acid, Dodecanoic acid (Lauric acid), p-Toluenesulfonic Acid (PTSA), 1-Octanesulfonic acid, Sodium dodecyl sulfate, 1-Ethylpyridinium bromide
Condition
Column | Newcrom BH, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | Gradient MeCN -40-80%, 10 min |
Buffer | Ammonium formate pH 3.0 – 40 mM |
Flow Rate | 1.0 ml/min |
Detection | ELSD, 50C |
Description
Class of Compounds | Surfactants |
Analyzing Compounds | Benzalkonium chloride, Cetylpyridinium Chloride, 1-Pentanesulfonic acid, Dodecanoic acid (Lauric acid), p-Toluenesulfonic Acid (PTSA), 1-Octanesulfonic acid, Sodium dodecyl sulfate, 1-Ethylpyridinium bromide |
Application Column
Newcrom BH
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
1-Octanesulfonic acid
1-Pentanesulfonic acid
Benzalkonium chloride
Cetylpyridinium Chloride
Dodecanoic acid (Lauric acid)
Sodium dodecyl sulfate
p-Toluenesulfonic Acid (PTSA)
HPLC Method for Separation of Hydrophobic, Cationic, Nonionic and Anionic Surfactants on Newcrom BH Column
July 10, 2023
HPLC Method for Separation of Hydrophobic, Cationic, Nonionic and Anionic Surfactants on Newcrom BH by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
Surfactants, also known as surface-active agents, are compounds that lower the surface tension (or interfacial tension) between two liquids or between a liquid and a solid. Surfactants may act as detergents, wetting agents, emulsifiers, foaming agents, or dispersants.
They are often classified according to the charge of the polar head group:
Anionic Surfactants: These surfactants have a negative charge on their polar head group. Common examples include soap, sodium laureth sulfate, and sodium lauryl sulfate. They are commonly used in detergents and shampoos due to their ability to emulsify oils and hold dirt in suspension, so it can be rinsed away.
Cationic Surfactants: These surfactants have a positive charge on their polar head group. Examples include cetyltrimethylammonium bromide (CTAB) and benzalkonium chloride. These are often used as antiseptics and can also be found in hair conditioners because they reduce static cling.
Nonionic Surfactants: These surfactants have no charge on their polar head group. Examples include alcohol ethoxylates, nonylphenol ethoxylates, and polysorbates. Nonionic surfactants are often used in laundry and dishwasher detergents.
All compounds can be retained, separated, and analyzed using a reverse-phase Newcrom BH, 4.6 x 250 mm, 5 µm, 100 A column. The mobile phase for this method consists of water, acetonitrile (MeCN), and Ammonium formate, which serves as a buffer. This analytical method can be detected with an Evaporative Light Scattering Detector (ELSD) or any other evaporative detection method (CAD, ESI-MS).
High Performance Liquid Chromatography (HPLC) Method for Analysis of Benzalkonium chloride, Cetylpyridinium Chloride, Triton X100, 1-Pentanesulfonic acid, 1-Hexanesulfonic acid, sodium salt, 1-Heptanesulfonic acid, 1-Decanesulfonic acid, Sodium dodecyl sulfate, 1-Octanesulfonic acid
Condition
Column | Newcrom BH, 4.6 x 250 mm, 5 µm, 100 A |
Mobile Phase | Gradient MeCN -40-80%, 30 min |
Buffer | Ammonium formate pH 3.0 – 20 mM |
Flow Rate | 1.0 ml/min |
Detection | ELSD, 50C |
Description
Class of Compounds | Aliphatic sulfonic acid |
Analyzing Compounds | Benzalkonium chloride, Cetylpyridinium Chloride, Triton X100, 1-Pentanesulfonic acid, 1-Hexanesulfonic acid, sodium salt, 1-Heptanesulfonic acid, 1-Decanesulfonic acid, Sodium dodecyl sulfate, 1-Octanesulfonic acid |
Application Column
Newcrom BH
Column Diameter: 4.6 mm
Column Length: 250 mm
Particle Size: 5 µm
Pore Size: 100 A
1-Heptanesulfonic acid
1-Hexanesulfonic acid, sodium salt
1-Octanesulfonic acid
1-Pentanesulfonic acid
Benzalkonium chloride
Cetylpyridinium Chloride
Sodium dodecyl sulfate
Triton X100
HPLC Determination of Sodium Dodecyl Sulfate on Newcrom B Column
April 7, 2020
Sodium dodecyl sulfate, or sodium lauryl sulfate, is a surfactant used in cleaning and hygienic products. It has a twelve carbon hydrophobic tail attached to a polar sulfate. Dodecyl sulfate can be retained on Newcrom B column in under 10 minutes with an MS-compatible mobile phase.
Column | Newcrom BH, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 70/30% |
Buffer | AmFm pH 3.0 – 60 mM |
Flow Rate | 1.0 ml/min |
Detection | CAD (Corona) MS- compatible mobile phase |
Class of Compounds |
Hydrophobic, Base, Ionizable, Anionic surfactant |
Analyzing Compounds | Sodium Dodecyl Sulfate |
Application Column
Newcrom BH
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Determination of Sodium Dodecyl Sulfate on Primesep B4 Column
June 7, 2019
Sodium dodecyl sulfate, or sodium lauryl sulfate, is a surfactant used in cleaning and hygienic products. It has a twelve carbon hydrophobic tail attached to a polar sulfate. Dodecyl sulfate can be retained on Primesep B4 column in under 5 minutes with an MS-compatible mobile phase. Primesep B4 is a short carbon chain reverse-phase (RP) mixed-mode column with embedded basic ion-pairing groups.
Column | Primesep B4, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 60/40% |
Buffer | AmFm pH 3.0 – 30 mM |
Flow Rate | 1.0 ml/min |
Detection | CAD (Corona) MS- compatible mobile phase |
Class of Compounds |
Hydrophobic, Base, Ionizable, Anionic surfactant |
Analyzing Compounds | Sodium Dodecyl Sulfate |
Application Column
Primesep B4
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsSeparation of Sodium dodecyl sulfate on Newcrom R1 HPLC column
February 16, 2018
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.