CAS Number | 306-08-1 |
---|---|
Molecular Formula | C9H10O4 |
Molecular Weight | 182.176 |
InChI Key | QRMZSPFSDQBLIX-UHFFFAOYSA-N |
LogP | 0.33 |
Synonyms |
|
Column | Primesep 200, 4.6*150 mm 5 µm, 100A |
Mobile Phase | MeCN/H2O |
Buffer | H2SO4 |
Flow Rate | 1.0 ml/min |
Detection | UV, 215 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Hormone |
Analyzing Compounds | Uracil, Epinephrine, DOPA, 2,6-Lutidine, Benzylamine, Hydroxytrypthophan, Homovanillic acid, Phenol, Tryptophan , 2,3-DHBA, Benzoic acid, Methylparaben, Ethylparaben, Toluene, Amitriptyline |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options
Application Notes: Neurotransmitters DOPAC, homovanillic acid and dopamine were separated by mixed-mode chromatography on Primesep 100 and Primesep 200 HPLC columns. The method can be used for quantification of neurotransmitters with LC/MS compatible conditions. The compounds are retained by combination of reversed-phase, ion-exchange or ion-exclusion mechanisms. The retention time and selectivity of separation can be adjusted by variation of amount of acetonitrile, buffer pH and buffer concentration.
Application Columns: Primesep 100
Application compounds: Dopac, Homovanillic Acid, Dopamine
Detection technique: UV, LC/MS, ELSD/CAD
Column | Primesep 100, 4.6×50 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 5/95% |
Buffer | AmFm pH 3.0- 30 mM |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Acid, Monocarboxylic acid, Hydrophilic, Ionizable, Hormone |
Analyzing Compounds | DOPAC, Homovanillic Acid, Dopamine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsThe Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options
Application Notes: Neurotransmitters DOPAC, homovanillic acid and dopamine were separated by mixed-mode chromatography on Primesep 100 and Primesep 200 HPLC columns. The method can be used for quantification of neurotransmitters with LC/MS compatible conditions. The compounds are retained by combination of reversed-phase, ion-exchange or ion-exclusion mechanisms. The retention time and selectivity of separation can be adjusted by variation of amount of acetonitrile, buffer pH and buffer concentration.
Application Columns: Primesep 100, Primesep 200
Application compounds: Dopac, Homovanillic Acid, Dopamine
Detection technique: UV, LC/MS, ELSD/CAD
Column | Primesep 200, 4.6×50 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 5/95% |
Buffer | AmFm pH 3.0- 30 mM |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Acid, Monocarboxylic acid, Hydrophilic, Ionizable, Hormone |
Analyzing Compounds | DOPAC, Homovanillic Acid, Dopamine |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsThe Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsColumn | Sharc 1, 3.2×50 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN/MeOH – 100/0 – 30/70% |
Buffer | Formic Acid – 0.5% AmFm 0.05% 7 min |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Acid, Monocarboxylic acid, Hydrophilic, Ionizable, Hormone |
Analyzing Compounds | DOPAC, Homovanillic Acid, Dopamine |
The SHARC™ family of innovative columns are are the first commercially available columns with separation based primarily on hydrogen bonding. SHARC stands for Specific Hydrogen-bond Adsorption Resolution Column. Hydrogen bonding is an interaction (attraction) of bound hydrogen atom to the molecules with electronegative atoms such as oxygen, nitrogen, and fluorine.
Select optionsCatecholamines are chemical compounds derived from the amino acid tyrosine containing catechol and amine groups. Some of them are biogenic amines. Retention of compounds of the catecholamine pathway is achieved on Obelisc N column. All polar compounds are well retained by combination of HILIC and ion-exchange mechanisms. Obelisc N columns produce very good peak shapes for all analytes. The method is very sensitive to amount of ACN, buffer and buffer pH. The retention time changes with variation of the main parameters. This method can be used for quantitation of biogenic amines and related compounds (homovanillic acid, dihydroxyphenyl acetic acid, serotonin, dopamine, epinephrine, hydroxytryptophan, epinephrine and DOPA) in urine, blood and other biological fluids. Further optimization of this HPLC method can be used during screening and validation. Amines and acids can be analyzed in the same run and retained by a combination of polar organic mode, cation-exchange and anion-exchange modes. Various buffers within specified pH can be employed (ammonium formate, ammonium acetate, sodium phosphate, etc.).
Column | Obelisc N, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O |
Buffer | AmAc pH 4.0- 30 mM |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Acid, Monocarboxylic acid, Hydrophilic, Ionizable, Hormone |
Analyzing Compounds | Homovanillic acid, Dihydroxyphenyl acetic acid, Serotonin, Dopamine, Epinephrine, Hydroxytryptophan, DOPA |
SIELC has developed the mixed-mode Obelisc™ columns to be the first commercially available columns with Liquid Separation Cell technology (LiSC™). This cost effective duo can replace multiple HPLC columns such as reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion- exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - Buffer concentration, Buffer pH, and Organic Modifier Concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsColumn | Newcrom B , 3.2×50 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 20/80% |
Buffer | H3PO4 – 0.1% |
Flow Rate | 0.5 ml/min |
Detection | UV, 275 nm |
Vanilmandelic, hydroxyindoleacetic and homovanillic acids are metabolites of various neurotransmitters that are used in urine tests to measure the levels of those neurotransmitters in the body. They can be baseline separated on a reverse-phase Primesep D HPLC column by varying the buffers and pH of the mobile phase consisting of water and acetonitrile (MeCN, ACN). UV detection at 230nm.
Column | Primesep D, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | TFA, AmFm |
Flow Rate | 1.0 ml/min |
Detection | UV, 230 nm |
Class of Compounds |
Acid, Monocarboxylic acid, Hydrophilic, Ionizable |
Analyzing Compounds | Vanilmandelic, Hydroxyindoleacetic, Homovanillic Acid |
The Newcrom columns are a family of reverse phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 columns are standard reverse phase columns with octyldecyl silane chains (C18) attached to porous silica. We have also designed a line of Newcrom R1 columns with a new outer design. This column and corresponding adapter entirely eliminate the need for any high-pressure fittings or tubing as well as minimizing all possible dead volumes. Furthermore, if a leak ever occurs in the high-pressure column inlet, the mobile phase is contained within the column adapter (no external leakage).
Select optionsThe Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options© SIELC Technologies. 2002 - 2023
Address: 804 Seton Court, Wheeling, IL USA 60090
Tel: (847) 229-2629 | Fax: (847) 655-6079
Sales, Refund and Returns Policy
Email: mail@sielc.com | Sitemap