2,3-Dihydroxybenzoic Acid

2,3-Dihydroxybenzoic Acid

CAS Number303-38-8
Molecular FormulaC7H6O4
Molecular Weight154.121
InChI KeyGLDQAMYCGOIJDV-UHFFFAOYSA-N
LogP1.20
Synonyms
  • 2,3-Dihydroxybenzoic acid
  • Benzoic acid, 2,3-dihydroxy-
  • 303-38-8
  • o-Pyrocatechuic acid
  • 3-Hydroxysalicylic acid
  • 4-10-00-01414
  • Benzoic acid, 2,3-dihydroxy-
  • 1,2-Dihydroxybenzene-3-carboxylic acid
  • 2,3-Dihydroxybenzoesaure
  • acide 2,3-dihydroxybenzoique
  • acido 2,3-dihidroxibenzoico
  • Catecholcarboxylic acid
  • NSC 27435
  • Pyrocatechuic acid
  • BRN 2209117
  • EINECS 206-139-5
  • 2,3 DHB
  • 2,3-Dihydroxybenzoate
  • 2-Pyrocatechuate
  • 2-pyrocatechuic acid
  • 3-Hydroxysalicylate
  • Catecholcarboxylate
  • DHBA
  • DOBK
  • O-Pyrocatechuate
  • Pyrocatechuate
  • catechol-3-carboxylic acid

Applications:

HPLC Separation of Dihydroxybenzoic Acids on Newcrom B Column

April 24, 2020


Dihydroxybenzoic acids are aromatic compounds consisting of a phenolic ring and a carboxylic acid. The six main compounds are structurally similar and are difficult to separate in reverse-phase HPLC. The can be separated by using a mixed-mode Newcrom B column with the mobile phase having either methanol (MeOH) or acetonitrile (ACN) as an organic modifier having different retention characteristics. Using the gradient of organic modifier, water and sulfuric acid (H2SO4) as buffer, dihydroxybenzoic acids can be separated and UV detected at 250nm.

Condition

Column Newcrom B, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN
Buffer H2SO4
Flow Rate 1.0 ml/min
Detection UV, 250 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements
Analyzing Compounds 3.4-dihydroxybenzoic acid, 3.5-dihydroxybenzoic acid,2,4-dihydroxybenzoic acid, 2,5-dihydroxybenzoic acid, 2,3-dihydroxybenzoic acid, 2,6-dihydroxybenzoic acid

 

Application Column

Newcrom B

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
2,3-Dihydroxybenzoic Acid
2,4-Dihydroxybenzoic Acid
2,5-Dihydroxybenzoic Acid
2,6-Dihydroxybenzoic acid
3,4-Dihydroxybenzoic Acid
3,5-Dihydroxybenzoic Acid
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Generic Screening Method for Complex Mixtures on Primesep 200

October 15, 2015

Condition

Column Primesep 200, 4.6*150 mm 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer H2SO4
Flow Rate 1.0 ml/min
Detection UV, 215 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Hormone
Analyzing Compounds Uracil, Epinephrine, DOPA, 2,6-Lutidine, Benzylamine, Hydroxytrypthophan, Homovanillic acid, Phenol, Tryptophan , 2,3-DHBA, Benzoic acid, Methylparaben, Ethylparaben, Toluene, Amitriptyline

 

Application Column

Primesep 200

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
2,3-Dihydroxybenzoic Acid
2,6-Lutidine
Amitriptyline
Benzoic Acid
Benzylamine
DOPA (3,4-dihydroxy-L-phenylalanine)
Epinephrine
Ethylparaben
Homovanillic Acid
Hydroxytryptophan
Methylparaben
Phenol
Toluene
Tryptophan
Uracil

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Dihydroxybenzoic Acid

November 21, 2010


Separation of hydrophilic isomers is very difficult when only one mechanism of retention, like reversed-phase, is available. Isomers have very similar hydrophobic properties. In case of mixed-mode chromatography, small difference in hydrophobic and ionic properties allows to separate isomers. Isomers of dihydroxybenzoic acids are separated on a Primesep D column with good selectivity and peak shape. This method can be used for separation of other hydrophilic acidic compounds as well as hydrophobic basic compound.

Condition

Column Primesep D, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN
Buffer TFA
Flow Rate 1.0 ml/min
Detection UV, 250 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements
Analyzing Compounds 3.4-dihydroxybenzoic acid, 3.5-dihydroxybenzoic acid,2,4-dihydroxybenzoic acid, 2,5-dihydroxybenzoic acid, 2,3-dihydroxybenzoic acid

 

Application Column

Primesep D

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
2,3-Dihydroxybenzoic Acid
2,4-Dihydroxybenzoic Acid
2,5-Dihydroxybenzoic Acid
3,4-Dihydroxybenzoic Acid
3,5-Dihydroxybenzoic Acid

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Mixed-Mode Separation of Dihydroxybenzoic Acids

October 12, 2005

 

 

Primesep B offers better selectivity over traditional, reversed-phase C18 columns for separating regioisomers of aromatic dihydroxybenzoic acids (2,3-dihydroxybenzoic, 2,4-dihydroxybenzoic, 2,5-dihydroxybenzoic 3,4-dihydroxybenzoic, 3,5-dihydroxybenzoic acids) Primesep B combines reversed-phase and anion-exchange mechanism with a mass spec compatible mobile phase of water, acetonitrile (MeCN, ACN) and trifluoracetic acid (TFA).

Condition

Column Primesep B, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN
Buffer TFA
Flow Rate 1.0 ml/min
Detection UV, 270 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements
Analyzing Compounds 3.4-dihydroxybenzoic acid, 3.5-dihydroxybenzoic acid,2,4-dihydroxybenzoic acid, 2,5-dihydroxybenzoic acid, 2,3-dihydroxybenzoic acid

 

Application Column

Primesep B

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
2,3-Dihydroxybenzoic Acid
2,4-Dihydroxybenzoic Acid
2,5-Dihydroxybenzoic Acid
3,4-Dihydroxybenzoic Acid
3,5-Dihydroxybenzoic Acid
Carboxylic Acids

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.