Urea

Urea structural formula

CAS Number57-13-6
Molecular FormulaCH4N2O
Molecular Weight60.056
InChI KeyXSQUKJJJFZCRTK-UHFFFAOYSA-N
LogP-2.11
Synonyms
  • Urea
  • 57-13-6
  • Amide of carbonic acid
  • Aquacare
  • Aquadrate
  • Basodexan
  • CARBAMIDE
  • Carbamimidic acid
  • Carbonyl diamide
  • Elaqua XX
  • Eucerin 10% Urea Lotion
  • Harnstoff
  • Isourea
  • Keratinamin
  • Keratinamin Kowa
  • NSC 34375
  • Nutraplus
  • Onychomal
  • Optigen 1200
  • Pastaron
  • Pastaron 10
  • Pastaron 20
  • Pastaron 20 soft
  • Pastaron soft
  • Pseudourea
  • Rubinol ST 010
  • Urea perhydrate
  • Urea, potassium salt
  • Ureaphil
  • Ureophil
  • Urepeal
  • Urepeal L
  • Urepearl
  • Urevert
  • Uroderm
  • Varioform II
  • Aqua Care HP
  • Caswell No. 902
  • EINECS 200-315-5
  • EPA Pesticide Chemical Code 085702
  • NCI-C02119
  • Prespersion, 75 urea
  • Supercel 3000
  • Ultra Mide
  • Ureacin-40 Creme
  • Ureacin-10 lotion
  • Sterile urea
  • UNII-8W8T17847W
  • Antisepsis bolus
  • ARF
  • Alphadrate
  • B-I-k
  • Bromisovalum
  • Bubber shet
  • Calmurid
  • Calmurid HC
  • Carbaderm
  • Carbamide resin
  • Carbonyl diamine
  • Carbonyldiamine
  • Carmol
  • E927b
  • H2NC(O)NH2
  • Helicosol
  • Hyanit
  • Karbamid
  • Mocovina
  • Panafil
  • URE
  • beta-I-k
  • carbonyldiamide
  • ur
  • uree
  • 118548-06-4
  • 1202865-46-0
  • 1228376-38-2
  • 30535-50-3
  • 860639-56-1

Applications:

Uv-Vis Spectrum of Urea

January 26, 2026
Access the UV-Vis Spectrum SIELC Library
UV-Vis Spectrum of Urea.

If you are looking for optimized HPLC method to analyze Urea check our HPLC Applications library

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.

Application Analytes:
Urea
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Separation of Urea and Thiourea on Primesep S  Column

July 25, 2023

HPLC Method for Separation of Thiourea, Urea on Primesep S Column by SIELC Technologies

HPLC Method for Separation of Urea and Thiourea on Primesep S  Column by SIELC Technologies
HPLC Method for Analysis of Thiourea, Urea on Primesep S Column by SIELC Technologies

Urea is a white crystalline solid with the chemical formula CO(NH2)2. It has a wide variety of uses including but not limited to as fertilizer, due to its high nitrogen content, In the production of plastics, resins, and adhesives, in the manufacturing of animal feed, and as a raw material in the production of many industrial chemicals. In addition, it is also used as a component in certain skin creams and cosmetics due to its moisturizing properties. You can find detailed UV spectra of Urea and information about its various lambda maxima by visiting the following link.

Thiourea is a versatile chemical compound with the formula (NH2)2CS. It is structurally similar to urea, except that the oxygen atom is replaced by a sulfur atom. It is a white crystalline solid when pure. Thiourea is used in a variety of applications. It is a reagent in organic synthesis, often used in the toning of silver-gelatin photography prints, as a component of hair preparations and bleaches, and as a radioprotective agent in cancer therapy. In agriculture, thiourea is used as a soil treatment agent to promote germination and stimulate flowering and fruiting. You can find detailed UV spectra of Thiourea and information about its various lambda maxima by visiting the following link.

Using a Primesep S normal-phase column and a mobile phase consisting of water and Acetonitrile (MeCN) with no buffer, Thiourea, Urea can be retained, separated, and analyzed. This analysis method can be UV detected at 200 nm.

Condition

ColumnPrimesep S, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile PhaseMeCN -90%
BufferNo
Flow Rate1.0 ml/min
DetectionUV 200 nm

Description

Class of CompoundsAmide, Urea
Analyzing CompoundsThiourea, Urea

Application Column

Primesep S

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Thiourea
Urea

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Cyanamide, Dicyandiamide and Urea on Primesep S Column with Varies Mobile Phases

May 1, 2023

HPLC Method for Analysis of Cyanamide, Dicyandiamide, Urea on Primesep S Column by SIELC Technologies

HPLC Method for Analysis of Cyanamide, Dicyandiamide and Urea on Primesep S Column with Varies Mobile Phases. by SIELC Technologies
HPLC Method for Analysis of Cyanamide, Dicyandiamide, Urea on Primesep S Column by SIELC Technologies

Cyanamide is a highly reactive and toxic compound with the chemical formula H2CN2. It is primarily used in the production of fertilizers, pharmaceuticals, and other chemicals. It can be used as a soil fumigant to control pests and weeds. Cyanamide became known the first known interstellar molecule to contain the NCN when it was detected in spectral emissions from the Sgr B2 molecular cloud.

Dicyandiamide is a white crystalline solid with the chemical formula C2H4N4. It is often used as a slow-release fertilizer. It is also used in the production of pharmaceuticals, dyes, and resins. Dicyandiamide can also be used as a nitrification inhibitor in agriculture to reduce the loss of nitrogen from the soil. You can find detailed UV spectra of Dicyandiamide and information about its various lambda maxima by visiting the following link.

Urea is a white crystalline solid with the chemical formula CO(NH2)2. It has a wide variety of uses including but not limited to as fertilizer, due to its high nitrogen content, In the production of plastics, resins, and adhesives, in the manufacturing of animal feed, and as a raw material in the production of many industrial chemicals. In addition, it is also used as a component in certain skin creams and cosmetics due to its moisturizing properties. You can find detailed UV spectra of Urea and information about its various lambda maxima by visiting the following link.

Using a Primesep S normal-phase column and a mobile phase consisting of water and Acetonitrile (MeCN) with no buffer, Cyanamide, Dicyandiamide and Urea can be retained, separated, and analyzed. This analysis method can be UV detected at 200 nm.

Condition

ColumnPrimesep S, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile PhaseMeCN
BufferNo
Flow Rate1.0 ml/min
DetectionUV 200 nm

Description

Class of CompoundsAmide, Urea
Analyzing CompoundsCyanamide, Dicyandiamide, Urea

Application Column

Primesep S

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Cyanamide
Dicyandiamide
Urea

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Cyanamide, Dicyandiamide and Urea on Primesep S Column

April 28, 2023

HPLC Method for Analysis of Cyanamide, Dicyandiamide, Urea on Primesep S Column by SIELC Technologies

HPLC Method for Analysis of Cyanamide, Dicyandiamide and Urea on Primesep S column Column
HPLC Method for Analysis of Cyanamide, Dicyandiamide, Urea on Primesep S Column by SIELC Technologies

Cyanamide is a highly reactive and toxic compound with the chemical formula H2CN2. It is primarily used in the production of fertilizers, pharmaceuticals, and other chemicals. It can be used as a soil fumigant to control pests and weeds. Cyanamide became known the first known interstellar molecule to contain the NCN when it was detected in spectral emissions from the Sgr B2 molecular cloud.

Dicyandiamide is a white crystalline solid with the chemical formula C2H4N4. It is often used as a slow-release fertilizer. It is also used in the production of pharmaceuticals, dyes, and resins. Dicyandiamide can also be used as a nitrification inhibitor in agriculture to reduce the loss of nitrogen from the soil. You can find detailed UV spectra of Dicyandiamide and information about its various lambda maxima by visiting the following link.

Urea is a white crystalline solid with the chemical formula CO(NH2)2. It has a wide variety of uses including but not limited to as fertilizer, due to its high nitrogen content, In the production of plastics, resins, and adhesives, in the manufacturing of animal feed, and as a raw material in the production of many industrial chemicals. In addition, it is also used as a component in certain skin creams and cosmetics due to its moisturizing properties. You can find detailed UV spectra of Urea and information about its various lambda maxima by visiting the following link.

Using a Primesep S normal-phase column and a mobile phase consisting of water and Acetonitrile (MeCN) with no buffer, Cyanamide, Dicyandiamide, Urea can be retained, separated, and analyzed. This analysis method can be UV detected at 200 nm.

Condition

ColumnPrimesep S, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile PhaseMeCN – 90%
BufferNo
Flow Rate1.0 ml/min
DetectionUV 200 nm

Description

Class of CompoundsAmide, Urea
Analyzing CompoundsCyanamide, Dicyandiamide, Urea

Application Column

Primesep S

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Cyanamide
Dicyandiamide
Urea

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HILIC Retention of Polar Compounds on Primesep S

August 22, 2010


Three neutral polar compounds (urea, thiourea, and xanthine) are separated on a Primesep S HILIC cation-exchange column with LC/MS compatible mobile phase. The retention time is controlled by the amount of acetonitrile in the mobile phase.

Application Column

Primesep S

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Thiourea
Urea
Xanthine

Application Detection:
ELSD Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Separation of Urea and Hydrogen Peroxide

July 16, 2009

Urea and carbamide are separated by HILIC HPLC on Primesep N column. Both compounds can be monitored at low UV – 200 nm. Method can be used for determination and quantitation of hydrogen peroxide and urea in various matrices.

Application Column

Primesep N

Column Diameter: 3.2 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Hydrogen Peroxide
Urea

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.