CAS Number | 123-30-8 |
---|---|
Molecular Formula | C6H7NO |
Molecular Weight | 109.128 |
InChI Key | PLIKAWJENQZMHA-UHFFFAOYSA-N |
LogP | 0.04 |
Synonyms |
|
Applications:
HPLC Method for Analysis of 4-Aminophenol on Primesep 100 Column
February 1, 2023
HPLC Method for Analysis of 4-Aminophenol on Primesep 100 by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
High Performance Liquid Chromatography (HPLC) Method for Analyses of 4-Aminophenol
4-Aminophenol (also known as para-aminophenol or Rodinal) is a popular film developing compound and building block in organic chemistry reactions. Most notably, it is a key compound used in the production of acetaminophen (also known as paracetamol or Tylenol). 4-Aminophenol can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and an sulfuric acid (H2SO4) or Perchloric acid (HClO4)buffer. This analysis method can be detected in the UV regime at 275 nm.
Condition
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 10% |
Buffer | H2SO4 – 0.2% or HClO4 – 0.2% |
Flow Rate | 1.0 ml/min |
Detection | UV 200, 210, 275 nm |
Peak Retention Time | 3.7 min, 6.9 |
Description
Class of Compounds | Alcohols, Phenols, Amines, Amine Salts |
Analyzing Compounds | 4-Aminophenol |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select options4-Aminophenol hydrochloride
HPLC Method for Separation of Acetaminophen and 4-Aminophenol on Primesep 100 Column
January 31, 2023
HPLC Method for Separation of Acetaminophen and 4-Aminophenol on Primesep 100 by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
High Performance Liquid Chromatography (HPLC) Method for Separation of Acetaminophen and 4-Aminophenol
4-Aminophenol (also known as para-aminophenol or Rodinal) is a popular film developing compound and building block in organic chemistry reactions. Most notably, it is a key compound used in the production of acetaminophen (also known as paracetamol or Tylenol). 4-Aminophenol can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and an sulfuric acid (H2SO4) or perchloric acid (HClO4) buffer. This analysis method can be detected in the UV regime at 220 nm.
Condition
Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN – 10% |
Buffer | H2SO4 – 0.2% or HClO4 – 0.2% |
Flow Rate | 1.0 ml/min |
Detection | UV 220 nm |
Peak Retention Time | 4.25, 5.51 min |
Description
Class of Compounds | Alcohols, Phenols, Amines, Amine Salts, Dgru |
Analyzing Compounds | 4-Aminophenol, Acetaminophen |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Acetaminophen (Paracetamol)
HPLC Method for Analysis of 4-Aminophenol MS-compatible Mobile on Primesep 100 Column
December 9, 2022
High Performance Liquid Chromatography (HPLC) Method for Analysis of 4-Aminophenol MS-compatible Mobile Phase on Primesep 100 by SIELC Technologies.
Separation type: Liquid Chromatography Mixed-mode
High Performance Liquid Chromatography (HPLC) Method for Analyses of 4-Aminophenol
4-Aminophenol (also known as para-aminophenol or Rodinal) is a popular film developing compound and building block in organic chemistry reactions. Most notably, it is a key compound used in the production of acetaminophen (also known as paracetamol or Tylenol). 4-Aminophenol can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and an Ammonium Formate (AmFm) buffer. This analysis method can be detected in the UV regime at 275 nm, and due to the Ammonium Formate buffer, is also compatible with evaporative detectors such as Evaporative Light Scattering Detectors (ELSD), Charged Aerosol Detection (CAD), and Electrospray Ionization (ESI) for Mass Spectrometry (MS).
Condition
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 10% |
Buffer | Ammonium Formate pH 3.0 – 20 mM |
Flow Rate | 1.0 ml/min |
Detection | UV 275 nm |
Peak Retention Time | 3.7, 5.8 min |
Description
Class of Compounds | Alcohols, Phenols, Amines, Amine Salts |
Analyzing Compounds | 4-Aminophenol |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select options4-Aminophenol hydrochloride
Separation of Acetaminophen and 4-Aminophenol on Primesep C
May 27, 2015
Acetaminophen and 4-Aminophenol ar both aminophenols. Acetominophen or paracetamol is a widely used analgesic and antipyretic. 4-Aminophenol is an intermediate in the synthesis of paracetamol and used in photography as a developer. Both compounds were retained and resolved on Primesep C. Primesep C is a mixed-mode HPLC column which uses reversed-phase and unique complex-forming groups to resolve compounds that might otherwise coelute.
Column | Primesep C, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | TEAPh |
Flow Rate | 1.0 ml/min |
Detection | UV, 210 nm |
Class of Compounds |
Drug, Hydrophilic, Ionizable |
Analyzing Compounds | Acetaminophen, 4-Aminophenol |
Application Column
Primesep C
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsAcetaminophen (Paracetamol)