4-Aminophenol hydrochloride

4-Aminophenol hydrochloride structural formula

CAS Number51-78-5
Molecular FormulaC6H8ClNO
Molecular Weight145.590
InChI KeyRVGOBWDGAVAVPJ-UHFFFAOYSA-N
LogP-0.00845
Synonyms
  • 4-Aminophenol hydrochloride
  • 4-Aminophenol--hydrogen chloride (1/1)
  • Phenol, 4-amino-, hydrochloride (1:1)
  • 51-78-5
  • C.I. Oxidation Base 6A
  • CI Oxidation Base 6A
  • Durafur Brown R
  • EINECS 200-122-6
  • Fouramine CP
  • Fourrine P
  • Fourrine 83
  • Furro P
  • Futramine P
  • p-Hydroxyaniline hydrochloride
  • Pelagol CP
  • Pelagol Grey CP
  • Peltol P
  • p-Aminophenol HCl
  • UNII-IWL2N22RFY

Applications:

HPLC Method for Analysis of 4-Aminophenol on Primesep 100  Column

February 1, 2023

HPLC Method for Analysis of 4-Aminophenol on Primesep 100 by SIELC Technologies

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of 4-Aminophenol on Primesep 100  Column
High Performance Liquid Chromatography (HPLC) Method for Analysis of 4-Aminophenol on Primesep 100 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of 4-Aminophenol on Primesep 100 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of 4-Aminophenol on Primesep 100 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analyses of 4-Aminophenol

4-Aminophenol (also known as para-aminophenol or Rodinal) is a popular film developing compound and building block in organic chemistry reactions. Most notably, it is a key compound used in the production of acetaminophen (also known as paracetamol or Tylenol). 4-Aminophenol can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and an sulfuric acid (H2SO4) or Perchloric acid (HClO4)buffer. This analysis method can be detected in the UV regime at 275 nm.

Condition

ColumnPrimesep 100, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN – 10%
BufferH2SO4 – 0.2% or HClO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV 200, 210, 275 nm
Peak Retention Time3.7 min, 6.9

Description

Class of CompoundsAlcohols, Phenols, Amines, Amine Salts
Analyzing Compounds4-Aminophenol

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
4-Aminophenol
4-Aminophenol hydrochloride
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of 4-Aminophenol MS-compatible Mobile on Primesep 100  Column

December 9, 2022

High Performance Liquid Chromatography (HPLC) Method for Analysis of 4-Aminophenol MS-compatible Mobile Phase on Primesep 100 by SIELC Technologies.

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of 4-Aminophenol on Primesep 100 Column by SIELC Technologies
HPLC Method for Analysis of 4-Aminophenol on Primesep 100 Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analyses of 4-Aminophenol

4-Aminophenol (also known as para-aminophenol or Rodinal) is a popular film developing compound and building block in organic chemistry reactions. Most notably, it is a key compound used in the production of acetaminophen (also known as paracetamol or Tylenol). 4-Aminophenol can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and an Ammonium Formate (AmFm) buffer. This analysis method can be detected in the UV regime at 275 nm, and due to the Ammonium Formate buffer, is also compatible with evaporative detectors such as Evaporative Light Scattering Detectors (ELSD), Charged Aerosol Detection (CAD), and Electrospray Ionization (ESI) for Mass Spectrometry (MS).

Condition

ColumnPrimesep 100, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN – 10%
BufferAmmonium Formate pH 3.0 – 20 mM
Flow Rate1.0 ml/min
DetectionUV 275 nm
Peak Retention Time3.7, 5.8 min

Description

Class of CompoundsAlcohols, Phenols, Amines, Amine Salts
Analyzing Compounds4-Aminophenol

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
4-Aminophenol
4-Aminophenol hydrochloride
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of 4-Aminophenol hydrochloride on Newcrom R1 HPLC column

February 16, 2018
Separation of 4-Aminophenol hydrochloride on Newcrom C18 HPLC column

4-Aminophenol hydrochloride can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
4-Aminophenol hydrochloride
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.