Proguanil hydrochloride

Proguanil hydrochloride structural formula

CAS Number637-32-1
Molecular FormulaC11H17Cl2N5
Molecular Weight290.191
InChI KeySARMGXPVOFNNNG-UHFFFAOYSA-N
LogP2.35
Synonyms
  • Proguanil hydrochloride
  • N-(4-Chlorophenyl)-N'-propan-2-yltriimidodicarbonic diamide--hydrogen chloride (1/1)
  • Imidodicarbonimidic diamide, N-(4-chlorophenyl)-N'-(1-methylethyl)-, hydrochloride (1:1)
  • 637-32-1
  • Bigumalum
  • Chlorguanide hydrochloride
  • Chloroguanide hydrochloride
  • Chloroguanidine hydrochloride
  • N-4-Chlorophenyl-N(sup 5)-isopropyldiguanide hydrochloride
  • N-(4-Chlorophenyl)-N(sup5)-isopropyldiguanide hydrochloride
  • Chloroquanil
  • Diguanyl
  • Drinupal hydrochloride
  • EINECS 211-283-7
  • Guanatol hydrochloride
  • NSC 12977
  • NSC 26614
  • Paludrine
  • Palusil hydrochloride
  • Tirian hydrochloride
  • Proguanil HCl
  • UNII-R71Y86M0WT

Applications:

HPLC Method for Analysis of Proguanil on Primesep 100 Column

February 1, 2024

High Performance Liquid Chromatography (HPLC) Method for Analysis of Proguanil hydrochloride on Primesep 100 by SIELC Technologies

Separation type: Liquid Chromatography Mixed-mode SIELC Technologies

HPLC Method for Analysis of Proguanil on Primesep 100 Column
HPLC Method for Analysis of Proguanil hydrochloride on Primesep 100 Column by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of Proguanil hydrochloride

Biguanides, including Moroxydine, Metformin, Proguanil, and Phenformin, are a group of organic compounds that share a common structural feature, namely the presence of two guanidine groups.

Proguanil is an antimalarial medication often used in combination with other drugs, such as atovaquone. It is used for both prevention and treatment of malaria. Proguanil is a prodrug, and its active form inhibits the development of the malaria parasite in the liver.

These biguanides exhibit various pharmacological activities, and while some are primarily used for antidiabetic purposes, others have applications in antiviral or antimalarial treatments. It’s important to note that the safety and efficacy of these drugs depend on proper medical supervision and adherence to prescribed dosages.

Proguanil can be retained and analyzed using a Primesep 100 mixed-mode stationary phase column. The analysis employs an isocratic method with a simple mobile phase comprising water, acetonitrile (MeCN), and ammonium formate as a buffer. This method allows for detection using UV at 240 nm

ColumnPrimesep 100, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O 75/25%
BufferAmFm pH 3.0  – 30 mM
Flow Rate1.0 ml/min
DetectionUV 240 nm
Samples 0.5 mg/ml
Injection volume2 µl
LOD*8 ppb
* LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.

Class of Compounds
Biguanides
Analyzing CompoundsProguanil hydrochloride

Application Column

Primesep 100

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Proguanil hydrochloride

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Separation Biguanides such as Moroxydine, Metformin, Proguanil and Phenformin on Primesep 100 Column

February 1, 2024

High Performance Liquid Chromatography (HPLC) Method for Analysis of Moroxydine, Metformin, Proguanil and Phenformin on Primesep 100 by SIELC Technologies

Separation type: Liquid Chromatography Mixed-mode SIELC Technologies

HPLC method for separating Biguanides such as Moroxydine , Metformin, Proguanil and Phenformin on Primesep 100 Column
HPLC Method for Analysis of Metformin, Proguanil hydrochloride, Phenformin, Moroxydine on Primesep 100 Column by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of Moroxydine , Metformin, Proguanil and Phenformin

Biguanides, including Moroxydine, Metformin, Proguanil, and Phenformin, are a group of organic compounds that share a common structural feature, namely the presence of two guanidine groups.

Moroxydine:

  • Moroxydine is an antiviral medication used in the treatment of influenza. It is believed to inhibit the early stages of viral replication.

Metformin:

  • Metformin is an oral antidiabetic medication used to treat type 2 diabetes. It works by reducing glucose production in the liver and improving insulin sensitivity in peripheral tissues. Metformin is one of the most widely prescribed drugs for diabetes management.

Proguanil:

  • Proguanil is an antimalarial medication often used in combination with other drugs, such as atovaquone. It is used for both prevention and treatment of malaria. Proguanil is a prodrug, and its active form inhibits the development of the malaria parasite in the liver.

Phenformin:

  • Phenformin is an antidiabetic biguanide that was previously used to treat type 2 diabetes. However, due to the risk of lactic acidosis (a serious side effect), it has been largely withdrawn from the market in many countries.

These biguanides exhibit various pharmacological activities, and while some are primarily used for antidiabetic purposes, others have applications in antiviral or antimalarial treatments. It’s important to note that the safety and efficacy of these drugs depend on proper medical supervision and adherence to prescribed dosages.

Biguanides such as Moroxydine , Metformin, Proguanil and Phenformin be retained, separated and analyzed using a Primesep 100 mixed-mode stationary phase column. The analysis employs an isocratic method with a simple mobile phase comprising water, acetonitrile (MeCN), and ammonium formate as a buffer. This method allows for detection using UV at 240 nm

ColumnPrimesep 100, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O 70/30%
BufferAmFm pH 3.0  – 30 mM
Flow Rate1.0 ml/min
DetectionUV 240 nm
Samples1. 0.1 mg/ml
2. 0.1 mg/ml
3. 0.1 mg/ml
4. 0.1 mg/ml
Injection volume10 µl
LOD*1. 7 ppb
2. 7 ppb
3. 17 ppb
4. 18 ppb
* LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.

Class of Compounds
Biguanides
Analyzing CompoundsMetformin, Proguanil hydrochloride, Phenformin, Moroxydine

Application Column

Primesep 100

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Metformin
Moroxydine
Phenformin
Proguanil hydrochloride

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of Proguanil hydrochloride on Newcrom R1 HPLC column

May 16, 2018
Separation of Proguanil hydrochloride on Newcrom R1 HPLC column

Proguanil hydrochloride can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Proguanil hydrochloride
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.