Bisoprolol

Bisoprolol structural formula

CAS Number66722-44-9
Molecular FormulaC18H31NO4
Molecular Weight325.450
InChI KeyVHYCDWMUTMEGQY-UHFFFAOYSA-N
LogP1.87
Synonyms
  • Bisoprolol
  • 1-[(Propan-2-yl)amino]-3-[4-({2-[(propan-2-yl)oxy]ethoxy}methyl)phenoxy]propan-2-ol
  • 2-Propanol, 1-[4-[[2-(1-methylethoxy)ethoxy]methyl]phenoxy]-3-[(1-methylethyl)amino]-
  • 66722-44-9
  • 2-Propanol, 1-[4-[[2-(1-methylethoxy)ethoxy]methyl]phenoxy]-3-[(1-methylethyl)amino]-
  • Bisoprololum
  • UNII-Y41JS2NL6U
  • Bisocor
  • (+-)-1-((alpha-(2-Isopropoxyethoxy)-p-tolyl)oxy)-3-(isopropylamino)-2-propanol
  • (RS)-1-(4-(2-Isopropoxyethoxymethyl)phenoxy)-3-(isopropylamino)-2-propanol

Applications:

Uv-Vis Spectrum of Bisoprolol

September 29, 2026

Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Bisoprolol check our HPLC Applications library

UV/Vis.: λmax: 194 nm, 225 nm, 270 nm

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. This compound was diluted in a mixture of water and acetonitrile. The method was done with a mixture of water and acetonitrile.

 

 

 

 

 

Application Analytes:
Bisoprolol
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC MS Method for Analysis of Bisoprolol in Pharmaceutical Formulation on Primesep 100 Column

September 24, 2026

HPLC Method for Analysis of Bisoprolol on Primesep 100 by SIELC Technologies

HPLC Method for Analysis of Bisoprolol in on Primesep 100 Column

Bisoprolol is a beta-blocker with the chemical formula C18H31NO4. It is used primarily used to treat high blood pressure, heart failure, and chest pain. It works through targeting receptors, specifically epinephrine, in the heart, which slows heart rate and lowers blood pressure.

Bisoprolol can be retained and analyzed using the Primesep 100 stationary phase column. The analysis utilizes an isocratic method with a mobile phase consisting of acetonitrile, water, and Ammonium Formate. Detection is performed using LC MS.

Condition

ColumnPrimesep 100, 3.2 x 100 mm, 5 µm, 100 A, dual ended
Mobile PhaseMeCN/H2O – 60/40%
BufferAmmonium formate pH 3.0 – 40 mM
Flow Rate0.5 ml/min
DetectionUV 272 nm, LC MS ESI-SIM 326 (M+H)+

Description

Class of CompoundsDrug
Analyzing CompoundsBisoprolol

Application Column

Primesep 100

Column Diameter: 3.2 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Bisoprolol

Application Detection:
LC MS Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Chiral Separation of Bisoprolol Enantiomers on Cyralis CM Column

September 23, 2026

HPLC Chiral Method for Analysis of Bisoprolol Enantiomers on Cyralis CM Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Bisoprolol.

Bisoprolol is a beta-blocker with the chemical formula C18H31NO4. It is used primarily used to treat high blood pressure, heart failure, and chest pain. It works through targeting receptors, specifically epinephrine, in the heart, which slows heart rate and lowers blood pressure.

This application describes a normal-phase chiral HPLC method for the separation of Bisoprolol enantiomers using SIELC’s Cyralis CM chiral column. Cyralis CM is a cellulose-based chiral stationary phase (CSP) designed for enantiomeric separations, optical purity testing, chiral impurity analysis, and stereoisomer characterization in pharmaceutical, chemical, agrochemical, and fine chemical applications. For best results, the sample should be prepared fresh for analysis.

Bisoprolol can be retained and analyzed using the Cyralis CM stationary phase column. The analysis utilizes an isocratic method with a mobile phase consisting of sodium Hexane, Ethanol, and DEA. Detection is performed using UV.

Condition

ColumnCyralis CM, 4.6 x 100 mm, 5 µm, 100 A, normal phase
Mobile PhaseHexane/Ethanol/DEA
Flow Rate1.0 mL/min
DetectionUV 230 nm
Resolution1.98

Description

Class of CompoundsDrug
Analyzing CompoundsBisoprolol

Application Column

Cyralis CM

Column Diameter: 4.6 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: normal phase

Add to cart
Application Analytes:
Bisoprolol

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of Bisoprolol on Newcrom R1 HPLC column

February 16, 2018
Separation of Bisoprolol on Newcrom C18 HPLC column

Bisoprolol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Bisoprolol
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us before ordering the column as there may be a more suitable column alternative by either e-mail: support@sielc.com or by phone: 847-229-2629.