CAS Number | 22573-93-9 |
---|---|
Molecular Formula | C26H56N10 |
Molecular Weight | 508.8 |
InChI Key | LFVVNPBBFUSSHL-UHFFFAOYSA-N |
LogP | 3.3 |
Synonyms |
Applications:
HPLC MS Method for Analysis of Alexidine on Primesep N Column
March 8, 2024
HPLC Method for Analysis of Alexidine on Primesep N Column by SIELC Technologies
Separation type: Liquid Chromatography Reversed-phase
Alexidine is a chemical compound that belongs to the class of bis-biguanide antiseptics. It is known for its antimicrobial properties and is used in various products for disinfection and antiseptic purposes. Alexidine has broad-spectrum antimicrobial activity, and it is commonly used in healthcare settings for its effectiveness against bacteria, fungi, and some viruses.
Alexidine can be retained and analyzed on a Primesep N mixed-mode stationary phase column using an analytical method with a simple mobile phase of water, Acetonitrile (MeCN) , and a ammonium formate as a buffer. This analysis method can be detected using LC MS.
High Performance Liquid Chromatography (HPLC) Method for Analyses of Alexidine on Primesep N Column by SIELC Technologies
Condition
Column | Primesep N, 2.1 x 100 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 85/15% |
Buffer | Ammonium Formate pH 3.0 – 10 mM |
Flow Rate | 0.2 ml/min |
Detection | SIM 255+, 509+ |
Description
Class of Compounds | Bis-biguanide |
Analyzing Compounds | Alexidine |
Application Column
Primesep N
Column Diameter: 2.1 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Method for Separation Alexidine and Polyhexanide on BIST B+ Column
January 23, 2024
High Performance Liquid Chromatography (HPLC) Method for Analysis of Polyhexanide PHMB, Alexidine on BIST B+ by SIELC Technologies
Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies
Alexidine and polyhexanide are both antiseptic agents used for various applications, particularly in the field of medicine and healthcare.
- Alexidine:
- Usage: Alexidine is a bisbiguanide antiseptic that is often used in oral care products, such as mouthwashes and dental formulations.
- Antimicrobial Properties: It has broad-spectrum antimicrobial properties, effective against bacteria, fungi, and some viruses.
- Application: Alexidine has been studied for its use in controlling oral biofilm and preventing dental plaque.
- Polyhexanide:
- Usage: Polyhexanide is a polymeric biguanide antiseptic that is used in various medical applications, including wound care and disinfection.
- Antimicrobial Properties: Similar to alexidine, polyhexanide has broad-spectrum antimicrobial properties and is effective against bacteria, fungi, and some viruses.
- Application: Polyhexanide is commonly used as an antiseptic solution for wound irrigation and for the treatment of infected wounds. It can also be found in some contact lens solutions.
Both alexidine and polyhexanide belong to the biguanide class of antiseptics, and they are known for their effectiveness against a wide range of microorganisms. The specific applications and formulations may vary based on the intended use, and these agents are often used in healthcare settings to prevent infections.
Alexidine and polyhexanide can be retained, separated and analyzed on a BIST B+ mixed-mode stationary phase column using an analytical method with a simple mobile phase of water, Acetonitrile (MeCN) , and a sulfuric acid as a buffer. This analysis method can be detected using UV at 200 nm.
High Performance Liquid Chromatography (HPLC) Method for Analyses of Polyhexanide PHMB, Alexidine
Condition
Column | BIST B+, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase* | Step Gradient A: MeCN – 75%, H2SO4 – 0.1% / 3 min B: MeCN – 0%, H2SO4 – 0.1% / 6 min |
Buffe | H2SO4 -0.1% |
Flow Rate | 1.0 ml/min |
Detection | UV 200 nm |
Sample | 1. 0.14 mg/ml 2. 0.26 mg/ml |
LOD ** | 8 ppb, 10 ppb |
Injection volume | 10 µl |
*The step gradient methods involve sudden changes in the solvent composition of the mobile phase, resulting in the baseline’s instability. It is necessary to account for this response to be able to interpret, integrate, and process results adequately. The blank sample (sample diluent) has to be analyzed before injecting the sample of interest. When all chromatograms are generated, it is necessary to subtract the blank chromatogram from the sample one before the integration step.
**LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed
Description
Class of Compounds | Bis-biguanide |
Analyzing Compounds | Polyhexanide PHMB, Alexidine |
Application Column
Polyhexanide PHMB
HPLC Method for Analysis of Alexidine on BIST B+ Column
January 16, 2024
High Performance Liquid Chromatography (HPLC) Method for Analysis of Alexidine on BIST B+ by SIELC Technologies
Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies
Alexidine is a chemical compound that belongs to the class of bis-biguanide antiseptics. It is known for its antimicrobial properties and is used in various products for disinfection and antiseptic purposes. Alexidine has broad-spectrum antimicrobial activity, and it is commonly used in healthcare settings for its effectiveness against bacteria, fungi, and some viruses.
Topical Antiseptics: In some formulations, alexidine is used as a topical antiseptic to disinfect skin and mucous membranes.
Oral Care Products: It is found in some mouthwashes and oral care products due to its antimicrobial properties.
Contact Lens Solutions: Alexidine is sometimes used in contact lens solutions to prevent microbial contamination.
Wound Care Products: It may be included in certain wound care products for its ability to prevent infection.
Alexidine can be retained and analyzed on a BIST B+ mixed-mode stationary phase column using an analytical method with a simple mobile phase of water, Acetonitrile (MeCN) , and a sulfuric acid as a buffer. This analysis method can be detected using UV at 200 nm.
High Performance Liquid Chromatography (HPLC) Method for Analyses of Alexidine
Condition
Column | BIST B+, 4.6 x 50 mm, 5 µm, 100 A |
Mobile Phase | MeCN – 82% |
Buffe | H2SO4 -0.1% |
Flow Rate | 1.0 ml/min |
Detection | UV 200 nm, UV λmax: 237 nm |
Sample | 0.4 mg/ml in MeCN/H2O – 82/18% |
LOD | 8 ppb |
Injection volume | 2 µl |
Description
Class of Compounds | Bis-biguanide |
Analyzing Compounds | Alexidine |