| CAS Number | 56129-55-6 |
|---|---|
| Molecular Formula | C7H10N2 |
| Molecular Weight | 122.17 |
| InChI Key | IQVQNBXPYJGNEA-UHFFFAOYSA-N |
| LogP | 0.1 |
| Synonyms |
|
Applications:
HPLC Chiral Separation of 1-pyridin-3-yl-ethylamine on Nonporous Cyralis Columns
October 16, 2026
HPLC Chiral Method for Analysis of 1-pyridin-3-yl-ethylamine Enantiomers on Cyralis Screening Kit Column by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of 1-pyridin-3-yl-ethylamine.
1-pyridin-3-yl-ethylamine has the chemical formula C7H10N2. You can find detailed UV spectra of 1-pyridin-3-yl-ethylamine and information about its various lambda maxima by visiting the following link.
This application describes a normal-phase chiral HPLC method for the separation of 1-pyridin-3-yl-ethylamine enantiomers using SIELC’s Cyralis nonporous chiral columns. The nonporous kit is a collection of AL, CL, AM and CM nonporous phases designed for ultrafast enantiomeric separations, optical purity testing, chiral impurity analysis, and stereoisomer characterization in pharmaceutical, chemical, agrochemical, and fine chemical applications. For best results, the sample should be prepared fresh for analysis. These nonporous applications are designed to demonstrate baseline resolution of certain racemates even on very short, low-capacity columns.
1-pyridin-3-yl-ethylamine can be retained and analyzed using the Cyralis Screening Kit stationary phase column. The analysis utilizes an isocratic method with a mobile phase consisting of hexane, IPA, and DEA. Detection is performed using UV.
Condition
| Column | Cyralis Screening Kit |
| Mobile Phase | Hexane/IPA/DEA – 99/1/0.5% |
| Flow Rate | 0.5 mL/min |
| Detection | UV 260 nm |
| Resolution | 1.52; 1.66 |
Description
| Class of Compounds | Compound |
| Analyzing Compounds | 1-pyridin-3-yl-ethylamine |
Application Column
UV-Vis Spectrum of 1-pyridin-3-yl-ethylamine
July 3, 2024
Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze 1-pyridin-3-yl-ethylamine check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
HPLC Determination of 1-pyridin-3-yl-ethylamine on Primesep 100 Column
December 29, 2021
HPLC Method for 1-pyridin-3-yl-ethylamine on Primesep 100 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of 1-pyridin-3-yl-ethylamine.
1-pyridin-3-yl-ethylamine has the chemical formula C7H10N2.
1-pyridin-3-yl-ethylamine can be retained on the Primesep 100 mixed-mode column using an isocratic analytical method with a simple mobile phase of water, acetonitrile (MeCN, ACN), and sulphuric acid (H2SO4) buffer. The analysis method can be UV detected at 260 nm.
| Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 20/80% |
| Buffer | H2SO4 – 0.3% |
| Flow Rate | 1.0 ml/min |
| Detection | UV, 260 nm |
| Class of Compounds |
Amine |
| Analyzing Compounds | 1-pyridin-3-yl-ethylamine |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended




