| CAS Number | 83915-83-7 |
|---|---|
| Molecular Formula | C21H35N3O7 |
| Molecular Weight | 441.525 |
| InChI Key | CZRQXSDBMCMPNJ-ZUIPZQNBSA-N |
| LogP | -0.0887 |
| Synonyms |
|
Applications:
HPLC Separation of Enalapril and Lisinopril on Newcrom AH Column
June 3, 2021
HPLC Method for Enalapril, Lisinopril, Lisinopril dihydrate on Newcrom AH by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Enalapril and Lisinopril
Enalapril is an ACE inhibitor medication with the chemical formula C20H28N2O5. It is used to treat hypertension, symptomatic heart failure, and asymptomatic left ventricular dysfunction. It also exhibited the ability to reduce the progression of kidney disease. Generic versions of it began their production in 2000.
Lisinopril is a medications that work on the kidneys to help lower blood pressure. It can be used for heart failure and for people who’ve had a heart attack. Like Enalapril, it is an ACE inhibitor. It has the chemical formula C21H31N3O5.
By using a Newcrom AH mixed-mode column with a cation-exchange mechanism, enalapril and lisinopril, can be baseline separated in a short time using an isocratic method with a simple mobile phase of water, acetonitrile (MeCN, ACN) and a sulfuric acid (H2SO4) buffer. UV detection at 210 nm.
| Column | Newcrom AH, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 50/50% |
| Buffer | H2SO4 – 0.5% |
| Flow Rate | 1.0 ml/min |
| Detection | UV, 210 nm |
| Class of Compounds |
Drug |
| Analyzing Compounds | Enalapril, Lisinopril, Lisinopril dihydrate |
Application Column
Newcrom AH
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Lisinopril
Lisinopril dihydrate
Separation of Lisinopril dihydrate on Newcrom R1 HPLC column
February 16, 2018
Lisinopril dihydrate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options