HPLC Method for Pralidoxime Chloride on Primesep 200 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Pralidoxime Chloride.
Pralidoxime Chloride, also known as 2-PAM, is a cholinesterase reactivator with the chemical formula C7H9N2O+. It is used as an antidote for poisoning by organophosphate pesticides and nerve agents.
Pralidoxime Chloride can be retained and analyzed using the Primesep 200 stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a [buffer] buffer. Detection is performed using UV.
Column | Primesep 200, 4.6 x 150 mm, 3 µm, 100 A, dual ended |
Mobile Phase | MeCN/H2O – 20/80% |
Buffer | H3PO4 – 0.1% |
Flow Rate | 1.0 ml/min |
Detection | UV, 200 nm |
Class of Compounds |
Drug, Basic, Hydrophobic, Ionizable |
Analyzing Compounds | Pralidoxime Chloride |
Application Column
Primesep 200
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: dual ended