Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate

Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate structural formula

CAS Number52829-07-9
Molecular FormulaC28H52N2O4
Molecular Weight480.735
InChI KeyXITRBUPOXXBIJN-UHFFFAOYSA-N
LogP6.13
Synonyms
  • Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
  • Bis(2,2,6,6-tetramethylpiperidin-4-yl) decanedioate
  • Decanedioic acid, bis(2,2,6,6-tetramethyl-4-piperidinyl) ester
  • 52829-07-9
  • Decanedioic acid, bis(2,2,6,6-tetramethyl-4-piperidinyl) ester
  • Adeka LA 77
  • ADK Stab LA 77
  • ADK Stab LA 77Y
  • ADK Stab LA-77Y
  • Bis (2,2,6,6-tetramethyl-4-piperidyl) sebacate
  • Bis(2,2,6,6-tetramethyl-4-piperidine sebacate)
  • BIS(2,2,6,6-TETRAMETHYL-4-PIPERIDINYL) SEBACATE
  • Bis(2,2,6,6-tetramethyl-4-piperidyl) decanedioate
  • Bis(2,2,6,6-tetramethyl-4-piperidyl)sebacat
  • Bis(2,2,6,6-tetramethylpiperidin-4-yl) sebecate
  • DECANEDIOATE, BIS(2,2,6,6-TETRAMETHYL-4- PIPERIDINYL)
  • Decanedioic acid bis(2,2,6,6-tetramethyl-4-piperidinyl) ester
  • DECANEDIOIC ACID DIESTER 2,2,6,6-TETRAMETHYL-4-PIPERIDINYL
  • Decanedioic acid, 1,10-bis(2,2,6,6-tetramethyl-4-piperidinyl) ester
  • Lowilite 77
  • Sanol LS 700
  • Sanol LS 770
  • Sebacate de bis(2,2,6,6-tetramethyl-4-piperidyle)
  • SEBACATE, BIS(2,2,6,6-TETRAMETHYL-4-PIPERIDYL)
  • sebacato de bis(2,2,6,6-tetrametil-4-piperidilo
  • Sumisorb 577
  • Tinuvin 770
  • Tinuvin 770DF
  • Tinuvin 770DF1
  • Tinuvin 770LS
  • Uvinul 4077
  • Bis(2,2,6,6-tetramethyl-4-piperidinyl) decanedioate
  • EINECS 258-207-9
  • UNII-6803A71201
  • Antioxidant 770
  • Eversorb 90
  • Uvinul 4077H
  • 115621-65-3
  • 121449-00-1
  • 127510-03-6
  • 149264-42-6
  • 152787-04-7
  • 331982-98-0
  • 64104-43-4
  • 908343-48-6
  • 91450-21-4

Applications:

Separation of Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate on Newcrom R1 HPLC column

February 16, 2018
Separation of Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate on Newcrom C18 HPLC column

Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.