| CAS Number | 407-41-0 |
|---|---|
| Molecular Formula | C3H8NO6P |
| Molecular Weight | 185.07 |
| InChI Key | BZQFBWGGLXLEPQ-REOHCLBHSA-N |
| Synonyms |
|
Applications:
Uv-Vis Spectrum of Phosphoserine
February 6, 2026

If you are looking for optimized HPLC method to analyze Phosphoserine check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.
HPLC Method for Analysis of Phosphoserine on Primesep B Column
November 19, 2024
High Performance Liquid Chromatography (HPLC) Method for Analysis of Phosphoserine on Primesep B by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Phosphoserine
Phosphoserine is a phosphorylated derivative of the amino acid serine, formed when a phosphate group is attached to its hydroxyl group. It plays a key role in cellular signaling and metabolic processes, serving as a precursor for the biosynthesis of important biomolecules like phospholipids, proteins, and nucleotides. Phosphoserine is also involved in protein phosphorylation, a critical post-translational modification regulating enzyme activity and signal transduction pathways.
Phosphoserine can be retained, separated and analyzed using a Primesep B mixed-mode stationary phase column. The analysis employs an isocratic method with a simple mobile phase comprising water, acetonitrile (MeCN), and phosphoric acid as a buffer. This method allows for detection using UV 200 nm.
| Column | Primesep B, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN – 10% |
| Buffer | H3PO4 – 0.3% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 200 |
| Sample | 1.0 mg/mL |
| Diluent | H2O- 100% |
| LOD* | 5.1 ppm |
| Class of Compounds | Amino acid |
| Analyzing Compounds | Phosphoserine |
Application Column
Primesep B
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended