| CAS Number | 4724-48-5 |
|---|---|
| Molecular Formula | C8H19O3P |
| Molecular Weight | 194.211 |
| InChI Key | NJGCRMAPOWGWMW-UHFFFAOYSA-N |
| LogP | 1.98 |
| Synonyms |
|
Applications:
Uv-Vis Spectrum of Octylphosphonic acid
February 13, 2026

If you are looking for optimized HPLC method to analyze Octylphosphonic acid check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.
HPLC Determination of Octylphosphonic acid on Newcrom A
May 4, 2021
HPLC Method for Octylphosphonic acid on Newcrom A by SIELC Technologies
Octylphosphonic acid (OPA) is a surfactant with the chemical formula C8H19O3P. It can be used to synthesize self-assembled monolayers (SAMs), polymeric matrices, and as a coating for super-resolution microscopy.
Using a Newcrom A mixed-mode column and a mobile phase consisting of water and acetonitrile (MeCN) with a formic acid buffer, OPA can be retained, measured, and analyzed. This analysis method can be used in conjunction with charged aerosol detection (CAD).
| Column | Newcrom AH, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 25/75% |
| Buffer | Formic Acid – 0.5% |
| Flow Rate | 1.0 ml/min |
| Detection | CAD |
| Class of Compounds |
Hydrophobic, Ionizable |
| Analyzing Compounds | Octylphosphonic acid |
Application Column
Newcrom AH
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Separation of Octylphosphonic acid on Newcrom R1 HPLC column
February 16, 2018
Octylphosphonic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options