HPLC Method for Analysis of Aminopterin on Primesep 100 Column

HPLC Method for Analysis of Aminopterin on Primesep 100 by SIELC Technologies

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of Aminopterin on Primesep 100 Column  by SIELC Technologies

Aminopterin is a chemical compound that belongs to the class of drugs known as antifolates. It’s a derivative of folic acid (vitamin B9) and works by inhibiting an enzyme called dihydrofolate reductase (DHFR). This enzyme plays a crucial role in the synthesis of nucleotides, the building blocks of DNA and RNA. By inhibiting this enzyme, aminopterin interferes with cell growth and division.

Aminopterin was one of the first antifolates to be used in cancer chemotherapy, particularly in the treatment of childhood leukemia. However, it has largely been replaced by methotrexate, a similar but less toxic compound. Methotrexate is still widely used in the treatment of various cancers and autoimmune diseases.

Despite its historical use in cancer treatment, aminopterin is extremely toxic and can cause severe side effects, including damage to the bone marrow, gastrointestinal tract, and skin. As a result, it is not typically used in human medicine today.

In addition to its role in chemotherapy, aminopterin has also been used in research to create what are known as “conditionally immortal” cell lines. It’s important to note that the use of aminopterin should always be overseen by professionals due to its high toxicity.

Aminopterin retained and analyzed using a reverse-phase Primesep 100, 4.6 x 150 mm, 5 µm, 100 A column. The mobile phase for this method consists of water, acetonitrile (MeCN), and ammonium formate, which serves as a buffer. This analytical method can be monitored using UV detection at 290 nm, an Evaporative Light Scattering Detector (ELSD), or any other evaporative detection method such as Charged Aerosol Detection (CAD) or Electrospray Ionization Mass Spectrometry (ESI-MS)

LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.

High Performance Liquid Chromatography (HPLC) Method for Analysis of Aminopterin

Condition

ColumnPrimesep 100, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O -50/50%
BufferAmmonium formate pH 3.0 – 20 mM
Flow Rate1.0 ml/min
DetectionUV 290 nm
Peak Retention Time5.08 min
Sample concentration0.02 mg/ml
Injection volume5 µl
Sample diluent H2O + NaOH
LOD0.04 ppm

Description

Class of CompoundsDrug, Aminopterin, Antifolates
Analyzing CompoundsAminopterin

Application Column

Primesep 100

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Aminopterin

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.