| CAS Number | 1197160-78-3 |
|---|---|
| Molecular Formula | C32H41N9O4 |
| Molecular Weight | 615.739 |
| InChI Key | DWZAEMINVBZMHQ-UHFFFAOYSA-N |
| LogP | 2.4 |
| Synonyms |
|
Applications:
HPLC MS Method for Analysis of Gedatolisib on Chromni Column
August 11, 2026
HPLC Method for Gedatolisib on Chromni by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Gedatolisib
Gedatolisib is an anti-cancer medication with the chemical formula C32H41N9O4. It is used as treatment for breast cancer. It works as a kinase inhibitor through binding the different p110 catalytic subunit isoforms of PI3K and the kinase site of mTOR
Gedatolisib can be retained and analyzed using the Chromni stationary phase column. The analysis utilizes a gradient method with a simple mobile phase consisting of water and acetonitrile (MeCN) with an sulfuric acid as a buffer. Detection is performed using LC MS.
| Column | Chromni, 3.2 x 100 mm, 3 µm, 100 A, dual ended |
| Mobile Phase | Gradient MeCN – 90 – 70%, 10 min |
| Buffer | AmFm pH 3.0 – 20 mM |
| Flow Rate | 0.5 ml/min |
| Detection | LC MS ESI SIM 616 [M+H]+ , 309 [(M+2H)/2]2+ ,UV 302 |
| Class of Compounds | Drug |
| Analyzing Compounds | Gedatolisib |
Application Column
Chromni
Column Diameter: 3.2 mm
Column Length: 100 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: dual ended
HPLC Method for Analysis of Gedatolisib on Chromni Column
August 10, 2026
HPLC Method for Gedatolisib on Chromni by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Gedatolisib
Gedatolisib is an anti-cancer medication with the chemical formula C32H41N9O4. It is used as treatment for breast cancer. It works as a kinase inhibitor through binding the different p110 catalytic subunit isoforms of PI3K and the kinase site of mTOR
Gedatolisib can be retained and analyzed using the Chromni stationary phase column. The analysis utilizes a gradient method with a simple mobile phase consisting of water and acetonitrile (MeCN) with an sulfuric acid as a buffer. Detection is performed using UV.
| Column | Chromni, 4.6 x 150 mm, 3 µm, 100 A, surface coated |
| Mobile Phase | Gradient MeCN – 90 – 70%, 10 min |
| Buffer | H2SO4 – 0.1% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 200 nm, 320 nm |
| Class of Compounds | Drug |
| Analyzing Compounds | Gedatolisib |
Application Column
Chromni
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: surface coated