Ethyl cyanoacrylate

Ethyl cyanoacrylate structural formula

CAS Number7085-85-0
Molecular FormulaC6H7NO2
Molecular Weight125.127
InChI KeyFGBJXOREULPLGL-UHFFFAOYSA-N
LogP0.779
Synonyms
  • Ethyl cyanoacrylate
  • Ethyl 2-cyanoprop-2-enoate
  • 2-Propenoic acid, 2-cyano-, ethyl ester
  • 7085-85-0
  • 2-Propenoic acid, 2-cyano-, ethyl ester
  • 2-cianoacrilato de etilo
  • 2-Cyano-2-propenoic acid ethyl ester
  • 2-Cyano-2-propenoic acid, ethyl ester
  • 2-cyanoacrylate d' ethyle
  • 2-Cyanoacrylate d'ethyle
  • 2-Cyanoacrylic acid ethyl ester
  • 2-Cyanoacrylic acid, ethyl ester
  • Acrylic acid, 2-cyano-, ethyl ester
  • Adhesive 502
  • Anacure 3020
  • Aron Alpha 402X
  • Aron Alpha D
  • Black Max
  • Cemedine 3000RP
  • Cemedine 3000RP Type-II
  • Cemedine 3000RS
  • Cemedine 3000RS Type-II
  • Cyanobond RP-X
  • Cyanobond W 100
  • Cyanobond W 300
  • Cyanon 5MSP
  • Cyanon S
  • Cyanon SL
  • Diabond 8200
  • ethyl 2-cyanoacrylate
  • ETHYL CYANOACRYLATE MONOMER
  • Ethyl ?-cyanoacrylate
  • Ethyl-2-cyanacrylat
  • ETHYL-2-CYANOACRYLATE
  • Loctite E 406
  • Phyx-All
  • PROP-2-ENOATE, 2-CYANO-, ETHYL
  • Sicomet 5195
  • Sicomet 8400
  • Sicomet Smart Power 100
  • Super 3-1000
  • Super Bonder 498
  • Super Glue
  • Three Bond 1741
  • Three Bond 1743
  • EINECS 230-391-5
  • UNII-2G95FOH7SF
  • 106717-55-9
  • 111940-93-3
  • 112002-50-3

Applications:

Separation of Ethyl cyanoacrylate on Newcrom R1 HPLC column

February 16, 2018
Separation of Ethyl cyanoacrylate on Newcrom C18 HPLC column

Ethyl cyanoacrylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Ethyl cyanoacrylate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.