CAS Number | 90-82-4 |
---|---|
Molecular Formula | C10H15NO |
Molecular Weight | 165.236 |
InChI Key | KWGRBVOPPLSCSI-WCBMZHEXSA-N |
LogP | 0.552 |
Synonyms |
|
Applications:
HPLC Method for Analysis of Pseudoephedrine on Primesep 100 Column
July 27, 2022
Separation type: Liquid Chromatography Mixed-mode
High Performance Liquid Chromatography (HPLC) Method for Analysis of Pseudoephedrine
Pseudoephedrine is one of the most popular decongestant drugs on the market (in part due to its efficacy and in part due to its status as an amphetamine). Fexofenadine is a common antihistamine used to treat hives, itching, and hay fever. Pseudoephedrine and Fexofenadine can be separated, retained, and analyzed on a Primesep 100 mixed-mode column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be UV detected at 200 nm with high resolution and peak symmetry.
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 60% |
Buffer | H2SO4 – 0.2% |
Flow Rate | 1.0 ml/min |
Detection | UV 200 nm |
Class of Compounds | Drug |
Analyzing Compounds | Pseudoephedrine |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsHPLC Method for Analysis of Pseudoephedrine and Fexofenadine from Allegra D Tablet on Primesep 100 Column
July 22, 2022
Separation type: Liquid Chromatography Mixed-mode
High Performance Liquid Chromatography (HPLC) Method for Analysis of Pseudoephedrine and Fexofenadine
Pseudoephedrine is one of the most popular decongestant drugs on the market (in part due to its efficacy and in part due to its status as an amphetamine). Fexofenadine is a common antihistamine used to treat hives, itching, and hay fever. Pseudoephedrine and Fexofenadine can be separated, retained, and analyzed on a Primesep 100 mixed-mode column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be UV detected at 200 nm with high resolution and peak symmetry.
Column | Primesep 100, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 65% |
Buffer | H2SO4 – 0.2% |
Flow Rate | 1.0 ml/min |
Detection | UV 200 nm |
Class of Compounds |
Drug |
Analyzing Compounds | Pseudoephedrine, Fexofenadine |
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsPseudoephedrine (PSE)
HPLC Method for Separation of NyQuil Active Ingredients on BIST B+ Column
October 18, 2021
Separation type: Bridge Ion Separation Technology, or BIST™
High Performance Liquid Chromatography (HPLC) Method for Analysis of Acetaminophen, Dextromethorphan, Pseudoephedrine, Doxylamine
Nyquil is a combination of medicines used to treat headaches, fever, body aches, cough, runny nose, sneezing, and sore throat caused by allergies, the common cold, or the flu. Nyquil contains the active ingredients acetaminophen, dextromethorphan HBr, doxylamine succinate, and sometimes, phenylephrine HCl. Acetaminophen is a pain reliever and fever reducer. Dextromethorphan is a cough suppressant. It affects the cough reflex in the brain that triggers coughing. Doxylamine is an antihistamine that reduces the effects of the natural chemical histamine in the body. Histamine can produce symptoms of sneezing, itching, watery eyes, and runny nose. Pseudoephedrine is used to relieve nasal congestion caused by colds, allergies, and hay fever. It is also used to temporarily relieve sinus congestion and pressure. All active compounds of Nyquil can be separated in HPLC on a BIST B+ column. The analytical method uses acetonitrile (ACN) gradient and water with sulfuric acid (H2SO4) as buffer and UV detected at 210 nm.
Column | BIST B+, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 90-60%, 10 min |
Buffer | H2SO4 – 0.4% |
Flow Rate | 1.0 ml/min |
Detection | UV, 210 nm |
Class of Compounds |
Drug, Basic, Hydrophobic, Ionizable |
Analyzing Compounds | Acetaminophen, Dextromethorphan, Pseudoephedrine, Doxylamine |
Application Column
BIST B+
BIST™ columns offer a unique and effective way to achieve separations that were traditionally challenging or even impossible with other HPLC columns. With the use of a special mobile phase, these ion exchange columns provide very strong retention for analytes with the same charge polarity as the stationary phase, unlocking new chromatography applications. What makes BIST™ columns stand out is their proprietary surface chemistry, which results in superior selectivity, resolution, and sensitivity. These columns offer a simple, efficient solution for a variety of analytical challenges, making them an excellent choice for researchers and analysts across many different fields. To learn more about the technology that powers BIST™ columns and to explore related applications, check out https://BIST.LC.
Select optionsAcetaminophen (Paracetamol)
Dextromethorphan
Doxylamine
Pseudoephedrine (PSE)
HPLC Separation of Pseudoephedrine, Norephedrine, Phenylephrine, and Norphenylephrine Using Hydrogen Bonding Mode
June 15, 2012
Application Notes: Neurotransmitters are polar basic compounds. Several HPLC techniques are used to analyze these hydrophilic molecules. The most common techniques are reversed-phase with ion-pairing reagents chromatography, ion chromatography, HILIC, and mixed-mode chromatography. SIELC developed a new approach of analysis, which is based on hydrogen bond interactions. Hydrogen-bonding offers unique and alternative selectivity to traditional approaches like reversed-phase, HILIC, ion-exchange, and mixed-mode chromatography. Our methods are fully compatible with ELSD, LC/MS and prep chromatography.
Application Columns: SHARC 1, 3.2×100 mm, 5 um, 100A. To learn more about SHARC 1 columns click here. To order this column click here. To see more chromatographic separations check our web site.
Application compounds: Pseudoephedrine, norephedrine, phenylephrine and norphenylephrine
Detection technique: UV, LC/MS
Column | Sharc 1, 3.2×100 mm, 5 µm, 100A |
Mobile Phase | MeCN/MeOH |
Buffer | AmFm, Formic acid |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements |
Analyzing Compounds | Pseudoephedrine, Norephedrine, Phenylephrine, Norphenylephrine |
Application Column
SHARC 1
The SHARC™ family of innovative columns represents the first commercially available columns primarily utilizing separation based on hydrogen bonding. SHARC stands for Specific Hydrogen-bond Adsorption Resolution Column. Hydrogen bonding involves an interaction or attraction between a bound hydrogen atom and molecules containing electronegative atoms, such as oxygen, nitrogen, and fluorine.
Select optionsNorphenylephrine
Phenylephrine
Pseudoephedrine (PSE)
HPLC Separation of NyQuil Active Ingredients
June 4, 2011
NyQuil is a cough medication produced by Procter&Gamble. It consists of acetaminophen, pseudoephedrine, doxylamine and dextromethorphan. Most of the analytical HPLC methods include either use of ion-pairing reagent or a gradient elution. Mixed-mode chromatography allows to replace long gradient method with short isocratic method. All four compounds are well separated within 3-5 minutes. Methods can be optimized for analysis of other cough composition containing general cough suppressants and pain killers. Method is robust and being validated at several drug companies.
Column | Primesep C, 4.6×50 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | TEAPh |
Flow Rate | 1.0 ml/min |
Detection | UV, 210 nm |
Class of Compounds |
Drug, Analgetic, Acid, Hydrophilic, Ionizable, |
Analyzing Compounds | Acetaminophen, Pseudoephedrine, Doxylamine, Dextromethorphan |
Application Column
Primesep C
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsDextromethorphan
Doxylamine
Pseudoephedrine (PSE)
HPLC Separation of Drugs
November 21, 2010
Mixed-mode chromatography allows to separate various hydrophobic and hydrophilic drugs in one HPLC method. Presence of at least two mechanism of retention allows adjust selectivity of separation by changing three parameters: amount of acetonitrile, buffer concentration and buffer pH. Seven common drugs are separated on a Primesep C trimodal HPLC column in gradient method. Method provides alternative selectivity to traditional reversed-phase chromatography. Operational range in which basic compounds are retained the most is from pH 3 to 5. At higher pH, longer retention can be achieved. Mixed-mode chromatography provides longer retention and better peak shapes for basic and acidic analytes. Method can be used in analysis of drugs and pharmaceuticals.
Column | Primesep C, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | Formic Acid |
Flow Rate | 1.0 ml/min |
Detection | UV, 250 nm |
Class of Compounds |
Drug, Analgetic, Acid, Hydrophilic, Ionizable, |
Analyzing Compounds | Norphenylephrine, Norephedrine, Pseudoephedrine, Doxylamine, Pyrilamine, Dextromethorphan, Trimipramine |
Application Column
Primesep C
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsDoxylamine
Norephedrine
Norphenylephrine
Pseudoephedrine (PSE)
Pyrilamine
HPLC Analysis of Pseudoephedrine and Citric Acid on Primesep Column
October 14, 2010
Pseudoephedrine is a drug used in cough and cold compositions. One of the preservatives in solutions of pseudoephedrine is citric acid. Both compounds are hydrophilic in nature, with pseudoephedrine being a basic compound and citric acid an acidic compound. Separation of these two compounds is achieved on a Primesep N column. Compounds are separated by combination of HILIC, cation-exchange and anion-exclusion mechanisms. Pseudoephedrine and citric acid are monitored by UV. This HPLC method can be adopted as generic approach for analysis of pseudoephedrine and other hydrophilic drugs and preservatives in mixtures.
Application Column
Primesep N
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Pseudoephedrine (PSE)
Comparison of the Separation of Polar Drugs on Obelisc R and Zorbax SB-AQ
March 3, 2010
Common hydrophobic basic and hydrophilic basic drugs are separated by mixed-mode chromatography with greater selectivity and resolution than traditional reversed-phase column. Drugs are retained by combination of reversed-phase and cation-exchange mechanisms. Retention time is controlled by amount of acetonitrile, buffer concentration and buffer pH. Available detection techniques are based on buffer selection and include UV, Evaporative Light-Scattering Detector (ELSD), Corona (CAD), LC/MS, etc. This HPLC method can be adopted as general approach for analysis of drugs and pharmaceuticals.
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsDextromethorphan
Doxylamine
Norephedrine
Norphenylephrine
Pseudoephedrine (PSE)
Pyrilamine
HPLC Analysis of Motrin Cough & Cold Composition
July 16, 2009
Motrin is cough and cold composition manufactured by McNeil PPC. It contains ibuprofen as non-steroidal anti-inflammatory drug (N-SAID) and pseudoephedrine as decongestant. Ibuprofen is hydrophobic acidic molecule and pseudoephedrine hydrophilic molecule. Pseudoephedrine does not retained well in reversed phase chromatography and requires the use of ion-pairing reagent. In the absence of ion-pairing reagent pseudoephedrine comes close to the void of the column even at low concentrations of acetonitrile, while ibuprofen shows strong retention by reversed-phase mechanism. Different properties of these two molecules require gradient elution and consequent equilibration of the column. In contrast when mixed-mode HPLC column, like Primesep 100, is used, the method can be isocratic, very short with no equilibration of the column. Ibuprofen is retained by strong reversed-phase mechanism and pseudoephedrine is retained by weak reversed-phase and strong cation-exchange mechanisms on Primesep 100 column. Retention time of hydrophobic molecule is controlled by amount of acetonitrile, and retention of hydrophilic basic molecule is controlled by the amount of buffer and buffer pH. Method can be UV, ELSD and LC/MS compatible with various additives to the mobile phase (TFA, ammonium formate or acetate, sulphate or phosphate buffers at various pH). This mixed-mode column can be used for analysis of other OTC drugs including mixtures of basic, acidic and hydrophobic compounds.
Application Column
Primesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsMotrin
Pseudoephedrine (PSE)
UV Detection
HPLC Separation of Drugs in Tylenol Cold and Cough Remedies
August 22, 2008
Components of Tylenol Cold and Cough Remedy are separated on Obelisc R mixed-mode column. Method can be used to determine compounds in various cough and cold compositions. Neutral (acetaminophen), basic (chlorpheniramine, dextromethorphan and pseudoephedrine) and acidic (maleic acid/Maleate) components are analyzed with perfect peak shape and retention control. Method can be used in production, QC/QA and biological studies for quantitation of various components in pharmaceutical formulations (Advil, Tylenol, Dimetapp, Robitussin, NyQuil, etc)
Column | Obelisc R, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | AmFm |
Flow Rate | 1.0 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Drug, Analgetic, Acid, Hydrophilic, Ionizable, Neutral, Basic |
Analyzing Compounds | Maleate, Chlorpheniramine, Dextromethorphan, Pseudoephedrine, Acetaminophen |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsChlorpheniramine
Dextromethorphan
Maleate
Pseudoephedrine (PSE)
HPLC Separation of Drugs in Advil Allergy and Sinus
August 22, 2008
Ibuprofen is in a group of drugs called non-steroidal anti-inflammatory drugs (NSAIDs). Ibuprofen works by reducing hormones that cause inflammation and pain in the body.
Pseudoephedrine is a decongestant that shrinks blood vessels in the nasal passages. Dilated blood vessels can cause nasal congestion (stuffy nose).
The combination of chlorpheniramine, ibuprofen, and pseudoephedrine is used to treat sneezing, itching, watery eyes, runny nose, stuffy nose, sinus congestion, cough, and pain or fever caused by the common cold or flu in common over-the-counter medication (Advil, NyQuil, Tylenol, etc.)
Active ingredients of Advil Allergy and Sinus composition are separated by combination of reverse phase, cation-exchange and anion exchange mechanisms. Obelisc R mixed-mode column is used to separate pseudoephedrine (polar basic compound), chlorpheniramine (hydrophobic basic compound), ibuprofen (hydrophobic acidic compound) and maleic acid (counter-ion, hydrophilic acid compound). Method can be used for QC in production, impurity profiling and research and development. All compounds are well separated with high efficiency and good peak shape. Method uses ammonium formate buffer but other buffers can be used as well (ammonium acetate, sodium and ammonium phosphate) with corresponding detection technique – ELSD, LC/MS, and UV. Chlorpheniramine is an antihistamine that reduces the natural chemical histamine in the body. Histamine can produce symptoms of sneezing, itching, watery eyes, and runny nose.
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsIbuprofen
Maleate
Pseudoephedrine (PSE)
Separation of NyQuil Active Ingredients on Primesep C
March 2, 2004
Primesep C separates the active ingredients in the over-the-counter cold medicine, NyQuil. Succinate and bromate co-elute early, but acetaminophen, pseudoephedrine, doxylamine, and dextromethorphan are baseline resolved. A combination of cation exchange, complex formation, and hydrophobic interactions separate this mixture with a mobile phase of water, acetonitrile (MeCN, ACN) and triethylamine (TEA) phosphate with UV detection at 205 nm.
Column | Primesep C, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | TEAPh |
Flow Rate | 1.0 ml/min |
Detection | UV, 205 nm |
Class of Compounds |
Drug, Analgetic, Acid, Hydrophilic, Ionizable, |
Analyzing Compounds | Acetaminophen, Pseudoephedrine, Doxylamine, Dextromethorphan |
Application Column
Primesep C
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsDextromethorphan
Doxylamine
Pseudoephedrine (PSE)