Biliverdin

CAS Number114-25-0
Molecular FormulaC33H34N4O6
Molecular Weight582.6
InChI KeyRCNSAJSGRJSBKK-NSQVQWHSSA-N
LogP2.5
Synonyms
  • biliverdin
  • biliverdine
  • Biliverdin IX alpha
  • Biliverdine Ix Alpha
  • uteroverdine
  • Biliverdin IX
  • dehydrobilirubin
  • Oocyan
  • 114-25-0
  • Biliverdine dihydrochloride
  • NSC 62793
  • 21H-Biline-8,12-dipropanoic acid, 3,18-diethenyl-1,19,22,24-tetrahydro-2,7,13,17-tetramethyl-1,19-dioxo-
  • UNII-O9MIA842K9
  • O9MIA842K9
  • CHEBI:17033
  • EINECS 204-042-2
  • Biliverdin IXalpha; Biliverdine (VAN)
  • 1,3,6,7-Tetramethyl-4,5-dicarboxyethyl-2,8-divinylbilenone
  • 8,12-bis(2-carboxyethyl)-2,7,13,17-tetramethyl-3,18-divinylbilin-1(19)(21H,24H)-dione
  • 1,19,22,24-tetrahydro-2,7,13,17-tetramethyl-1,19-dioxo-3,18-divinylbiline-8,12-dipropionic acid
  • NSC-62793
  • Protobiliverdin IX
  • 3-[(2Z,5Z)-2-[[3-(2-carboxyethyl)-5-[(Z)-(3-ethenyl-4-methyl-5-oxopyrrol-2-ylidene)methyl]-4-methyl-1H-pyrrol-2-yl]methylidene]-5-[(4-ethenyl-3-methyl-5-oxopyrrol-2-yl)methylidene]-4-methylpyrrol-3-yl]propanoic acid
  • BILIVERDINE [MI]
  • D06SCF
  • SCHEMBL51428
  • CHEMBL455477
  • SCHEMBL20503445
  • SCHEMBL24582034

Applications:

HPLC Method for Separation of Bilirubin and Biliverdin on Newcrom R1 Column

June 23, 2023

HPLC Method for Analysis of Bilirubin, Biliverdin on Newcrom R1 by SIELC Technologies

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of Bilirubin, Biliverdin on Newcrom R1 by SIELC Technologies

Bilirubin and biliverdin are both pigments that are part of the heme degradation pathway in the body. They are structurally related but have different properties and functions.

Bilirubin: This is a yellow compound that is produced by the liver from the breakdown of old red blood cells. It is responsible for the yellow color of bruises and the yellow discoloration seen in conditions such as jaundice and liver disease. Bilirubin is transported in the blood to the liver, where it is conjugated with glucuronic acid and excreted in bile.

Biliverdin: This is a greenish pigment that is an intermediate product in the pathway that produces bilirubin. When red blood cells reach the end of their lifespan (about 120 days), they are broken down in the spleen. The heme group from the hemoglobin in these cells is converted into biliverdin by the enzyme heme oxygenase. This biliverdin is then quickly reduced to bilirubin by biliverdin reductase.

While both these compounds are normal products of metabolism, elevated levels can indicate disease. High levels of bilirubin, for example, can cause jaundice, a condition that results in yellowing of the skin and eyes. Furthermore, since these molecules are breakdown products of heme, they are part of the body’s natural antioxidant defense system. Bilirubin and biliverdin can help protect cells from damage by neutralizing harmful free radicals.

Bilirubin and biliverdin are both part of a class of compounds called tetrapyrroles. More specifically, they belong to a group of tetrapyrroles known as bile pigments.

Tetrapyrroles are a group of organic compounds that contain four pyrrole rings. Heme, found in hemoglobin in red blood cells, is also a type of tetrapyrrole. The breakdown of heme leads to the formation of biliverdin, which is then converted to bilirubin. These bile pigments are then excreted from the body.

Bilirubin and biliverdin can be retained, separate and analyzed on a reverse-phase Newcrom R1, 2.1 x 150 mm, 3 µm, 100 A column with a mobile phase consisting of water and Acetonitrile (MeCN) and Ammonium acetate as a buffer. This analysis method can be detected with an Evaporative Light Scattering Detector (ELSD) or any other evaporative detection method (CAD, ESI-MS).

LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.

High Performance Liquid Chromatography (HPLC) Method for Analysis of Bilirubin, Biliverdin

Condition

ColumnNewcrom R1, 2.1 x 150 mm, 3 µm, 100 A
Mobile PhaseGradient MeCN/H2O -30-85%, 15 min
BufferGradient Ammonium acetate (pH unadjusted) – 100-40mM
Flow Rate0.2 ml/min
DetectionUV 405 nm
Peak Retention Time8.62, 12.8min
Sample concentration0.1 mg/ml
Injection volume2 µl
Sample diluent MeCN/H2O -50/50% +NaOH
LOD20 ppm

Description

Class of CompoundsTetrapyrroles
Analyzing CompoundsBilirubin, Biliverdin

Application Column

Newcrom R1

Column Diameter: 2.1 mm
Column Length: 150 mm
Particle Size: 3 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Bilirubin
Biliverdin

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.