Benzocaine

Benzocaine structural formula

CAS Number94-09-7
Molecular FormulaC9H11NO2
Molecular Weight165.193
InChI KeyBLFLLBZGZJTVJG-UHFFFAOYSA-N
LogP1.86
Synonyms
  • Benzocaine
  • Ethyl 4-aminobenzoate
  • Benzoic acid, 4-amino-, ethyl ester
  • 94-09-7
  • Ethyl 4-aminobenzoate
  • 4-14-00-01129
  • Benzoic acid, 4-amino-, ethyl ester
  • (p-(Ethoxycarbonyl)phenylamine
  • 4-(Ethoxycarbonyl)aniline
  • 4-(Ethoxycarbonyl)phenylamine
  • 4-AMINOBENZOESAEURE-AETHYLESTER
  • 4-Aminobenzoic acid ethyl ester
  • 4-Carbethoxyaniline
  • Aethoform
  • Amben ethyl ester
  • Americaine
  • Anaesthan-syngala
  • Anaesthesin
  • Anaesthin
  • Anestezin
  • Anesthesin
  • Anesthesine
  • Anesthone
  • Baby Anbesol
  • Benzoak
  • BENZOATE, 4-AMINO-, ETHYL
  • Benzocain
  • benzocaina
  • Benzoic acid, p-amino-, ethyl ester
  • Diet Ayds
  • Ethoform
  • Ethyl aminobenzoate
  • Ethyl p-aminobenzenecarboxylate
  • Ethyl p-aminobenzoate
  • Ethyl p-aminophenylcarboxylate
  • Gingicaine
  • Identhesin
  • Keloform
  • Norcain
  • Norcaine
  • NSC 41531
  • NSC 4688
  • Orabase-B
  • Ora-jel
  • Orthesin
  • p-(Ethoxycarbonyl)aniline
  • p-Aminobenzoic acid ethyl ester
  • Parathesin
  • Parathesine
  • p-Carbethoxyaniline
  • p-Ethoxycarboxylic aniline
  • Slim Mint Gum
  • Aethylium paraminobenzoicum
  • 4-Aminobenzoic acid, ethyl ester
  • Anaesthesinum
  • BRN 0638434
  • Caswell No. 430A
  • EINECS 202-303-5
  • EPA Pesticide Chemical Code 097001
  • Ethoforme
  • Ethylis aminobenzoas
  • Hurricaine
  • Norcainum
  • Topcaine
  • Chloraseptic
  • Benzocainum
  • Ethylester kyseliny p-aminobenzoove
  • UNII-U3RSY48JW5
  • Otocain
  • Finafta
  • 71123-91-6

Applications:

HPLC Method for Analysis of Benzocaine on Primesep 200 Column

April 13, 2026

HPLC Method for Benzocaine on Primesep 200 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Benzocaine

Benzocaine is a local anesthetic with the chemical formula C9H11NO2. It is primarily used to treat pain in the mouth, threat, and ears. On occasion it is also used on sunburns and hemorrhoids. It is also commonly used as a ingredient ibn other medications. You can find detailed UV spectra of Benzocaine and information about its various lambda maxima by visiting the following link.

Benzocaine can be retained and analyzed using the Primesep 200 stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a sulfuric acid as a buffer. Detection is performed using UV.

ColumnPrimesep 200, 3.2 x 150 mm, 3 µm, 100 A, dual ended
Mobile PhaseMeCN/H2O – 20/80 %
BufferH2SO4 – 0.1%
Flow Rate0.5 ml/min
DetectionUV
Limit of Detection*10 ppb
*LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.
Class of Compounds
 Amino Ester
Analyzing CompoundsBenzocaine

Application Column

Primesep 200

Column Diameter: 3.2 mm
Column Length: 150 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Benzocaine

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Uv-Vis Spectrum of Benzocaine

April 10, 2026

Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Benzocaine, Benzocaine check our HPLC Applications library

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. This analysis was done with the mobile phase made of 20% acetonitrile and 80% water.

 

 

 

 

Application Analytes:
Benzocaine
Benzocaine
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of Benzocaine on Newcrom R1 HPLC column

May 16, 2018
Separation of Benzocaine on Newcrom R1 HPLC column

Benzocaine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Benzocaine
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us before ordering the column as there may be a more suitable column alternative by either e-mail: support@sielc.com or by phone: 847-229-2629.