CAS Number | 63-74-1 |
---|---|
Molecular Formula | C6H8N2O2S |
Molecular Weight | 172.202 |
InChI Key | FDDDEECHVMSUSB-UHFFFAOYSA-N |
LogP | -0.6 |
Synonyms |
|
Antibiotics are widely used for treatment and prevention of bacterial infections. Various antibiotics, particularly those with a sulfanilamide structure, were separated in HPLC using mixed-mode columns with varying strengths of ion-pairing groups. Primesep 200 has weak acidic ion-exchange pairing groups while Newcrom A has strong acidic ion-exchange groups. In addition, methanol can be used in the mobile phase on Newcrom A column. The antibiotics were resolved on both columns with a gradient mobile phase consisting of acetonitrile (ACN) or methanol (MeOH), water and sulfuric acid (H2SO4) buffer. UV detection at 275nm.
Column | Primesep 200, 4.6×100 mm, 5 µm, 100A |
Mobile Phase | MeCN Gradient |
Buffer | H2SO4 – 0.5% |
Flow Rate | 1.0 ml/min |
Detection | UV 275 nm |
Column | Newcrom A, 3.2×100 mm, 5 µm, 100A |
Mobile Phase | MeOH Gradient |
Buffer | H2SO4 Gradient |
Flow Rate | 0.5 ml/min |
Detection | UV 275 nm |
Class of Compounds | Drugs, Antibiotics |
Analyzing Compounds | Sulfanilamide, Sulfadiazine, Sulfaguanidine, Dapsone, Sulfaquinoxaline |
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsThe Newcrom columns are a family of reverse phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse phase column with low silanol activity.
Select optionsColumn | Newcrom А, 3.2×50 mm, 3 µm, 100A |
Mobile Phase | MeOH/H2O – 80/20% |
Buffer | H2SO4 – 0.005% |
Flow Rate | 0.5 ml/min |
Detection | 275 nm |
Column | Primesep D, , Primesep 100 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 10/90% |
Buffer | Formic Acid – 0.1% |
Flow Rate | 0.5 ml/min |
Detection | UV 230 nm |
Both Benzenesulfonamide and sulfanilamide are organic antibacterial compounds differing only in the addition of an extra amino group in sulfanilamide. The closely related compounds can be separated on a mixed-mode Primesep D column by hydrophobic and anion-exchange mechanisms or Primesep 100 column by hydrophobic and cation-exchange mechanisms with the elution order reversed using identical mobile phases. UV Detection at 230nm.
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsThe Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select optionsPrimesep 100 separates a mixture of sulfonamides (benzenesulfonamide, chlorobenzenesulfonamide, hydroxybenzenesulfonamide) and hydroxysulphaminophenylhydrazine by a mixture of polar and hydrophobic interactions. The stationary phase’s hydrophobic functionality provides a reversed-phase mechanism while the embedded cation-exchange group provides polar interactions. The separation method uses a mobile phase mixture of water, acetonitrile (MeCN, ACN) and trifluoracetic acid (TFA) with UV detection at 210 nm. This method is mass spec (LC/MS) and evaporative light scattering (ELSD) compatible.
The Primesep family of mixed-mode columns offer a wide variety of stationary phases with an unprecedented selectivity in the separation of a broad array of chemical compounds and in multiple applications. Corresponding Primesep guard columns are available with all stationary phases and do not require holders. SIELC offers a method development service which is available for all customers. Ask about our special custom LC-phases tailored for specific separations.
Select options© SIELC Technologies. 2002 - 2023
Address: 804 Seton Court, Wheeling, IL USA 60090
Tel: (847) 229-2629 | Fax: (847) 655-6079
Sales, Refund and Returns Policy
Email: mail@sielc.com | Sitemap