3-Iodo-2-propynyl-N-butylcarbamate

3-Iodo-2-propynyl-N-butylcarbamate structural formula

CAS Number55406-53-6
Molecular FormulaC8H12INO2
Molecular Weight281.093
InChI KeyWYVVKGNFXHOCQV-UHFFFAOYSA-N
LogP3.04
Synonyms
  • 3-Iodo-2-propynyl-N-butylcarbamate
  • 3-Iodoprop-2-yn-1-yl butylcarbamate
  • Carbamic acid, N-butyl-, 3-iodo-2-propyn-1-yl ester
  • 55406-53-6
  • 3-Iodo-2-propynylbutylcarbamate
  • Carbamic acid, butyl-, 3-iodo-2-propynyl ester
  • Iodocarb
  • 3-Iod-2-propinylbutylcarbamat
  • 3-iodo-2-propynyl butylcarbamate
  • 3-Iodo-2-propynyl N-butylcarbamate
  • 3-Iodopropargyl n-butylcarbamate
  • 3-IODOPROPYNYL BUTYL CARBAMATE
  • Acticide IPW 50
  • Biodocarb
  • butilcarbamato de 3-iodo-2-propinilo
  • Butylcarbamate de 3-iodo-2-propynyle
  • CARBAMATE, 3-IODO-2-PROPYNYL BUTYL-
  • Carbamic acid, N-butyl-, 3-iodo-2-propyn-1-yl ester
  • Coatcide 123
  • Dekaben LMB
  • Ecobois
  • Fungitrol 720
  • Fungitrol 820
  • Glycacil
  • Glycasil L
  • Guardsan 388
  • Mergal 710S
  • N-BUTYLCARBAMINSAEURE-(3-JOD-2-PROPINYL)-ESTER
  • Omacide IPBC
  • Omacide IPBC 100
  • Polyphase
  • Polyphase 641
  • Polyphase AF 1
  • Polyphase CST
  • Polyphase P100
  • Preventol MP 100
  • Troysan Polyphase AF 3
  • Troysan Polyphase P 100
  • Troysan Polyphase P 20T
  • Troysan Polyphase WD 17
  • BRN 2248232
  • Caswell No. 501A
  • EINECS 259-627-5
  • EPA Pesticide Chemical Code 107801
  • Troysan KK-108A
  • Troysan polyphase anti-mildew
  • Woodlife
  • UNII-603P14DHEB
  • 3-iodo-2-propyn-1-yl N-butylcarbamate
  • 3-iodoprop-2-ynyl butylcarbamate
  • IPBC
  • Iodopropynyl butylcarbamate
  • butyl-3-iodo-2-propynylcarbamate
  • iodocarbe
  • 3-iodoprop-2-yn-1-yl butylcarbamate
  • 104732-42-5
  • 161849-41-8
  • 84826-91-5
  • 85045-09-6

Applications:

HPLC Determination of 3-Iodo-2-Propynyl Butylcarbamate on Newcrom R1 Column

April 30, 2019

HPLC Method for 3-Iodo-2-propynyl-N-butylcarbamate on Newcrom R1 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of 3-Iodo-2-propynyl-N-butylcarbamate.

Iodopropynyl Butyl Carbamate is a water-based preservative used in paints, coating, personal care and cosmetic industries. It is used because of its fungicide properties. It can be retained on Newcrom R1 reverse-phase column using an isocratic analytical method using a mobile phase of acetonitrile (ACN) and water with a phosphoric acid (H3PO4) buffer with UV detection at 200nm.

Condition

Column Newcrom R1, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile Phase MeCN/H2O – 50/50%
Buffer AmFm pH 3.0- 10 mM
Flow Rate 1.0 ml/min
Detection UV, 200 nm

 

Description

Class of Compounds
Preservative, Hydrophobic, Ionizable, Zwitterionic
Analyzing Compounds 3-Iodo-2-propynyl-N-butylcarbamate

 

Application Column

Newcrom R1

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
3-Iodo-2-propynyl-N-butylcarbamate

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of 3-Iodo-2-propynyl-N-butylcarbamate

April 30, 2019

HPLC Method for 3-Iodo-2-propynyl-N-butylcarbamate on Primesep SB by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of 3-Iodo-2-propynyl-N-butylcarbamate.

3-Iodo-2-propynyl-N-butylcarbamate, also known as idocarb,  has the chemical formula C8H12INO2. It is typically used as a preservative in paint, coatings, and wood preservatives.  In cosmetics, besides as a preservative, it is also used as a fungicide at low concentrations.

3-Iodo-2-propynyl-N-butylcarbamate can be retained and analyzed using the Primesep SB stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a phosphoric acid buffer. Detection is performed using UV.

Condition

Column Primesep SB, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile Phase MeCN/H2O – 40/60%
Buffer H3PO4 – 0.2%
Flow Rate 1.0 ml/min
Detection UV, 200 nm

 

Description

Class of Compounds
Preservative, Hydrophobic, Ionizable, Zwitterionic
Analyzing Compounds 3-Iodo-2-propynyl-N-butylcarbamate

 

Application Column

Primesep SB

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
3-Iodo-2-propynyl-N-butylcarbamate

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of 3-Iodo-2-propynyl-N-butylcarbamate on Newcrom R1 HPLC column

February 16, 2018
Separation of 3-Iodo-2-propynyl-N-butylcarbamate on Newcrom C18 HPLC column

3-Iodo-2-propynyl-N-butylcarbamate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
3-Iodo-2-propynyl-N-butylcarbamate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us before ordering the column as there may be a more suitable column alternative by either e-mail: support@sielc.com or by phone: 847-229-2629.