| CAS Number | 532-03-6 |
|---|---|
| Molecular Formula | C11H15NO5 |
| Molecular Weight | 241.243 |
| InChI Key | GNXFOGHNGIVQEH-UHFFFAOYSA-N |
| LogP | 0.61 |
| Synonyms |
|
Applications:
HPLC Chiral Separation of Methocarbamol Enantiomers on Cyralis CM Column
September 29, 2026
HPLC Chiral Method for Analysis of Methocarbamol Enantiomers on Cyralis CM Column by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Methocarbamol.
Methocarbamol is an drug with the chemical formula C11H15NO5. It is used primarily to treat short-term musculoskeletal pain, especially acute spasms. It is not yet clearly established how the drug works.
This application describes a normal-phase chiral HPLC method for the separation of Methocarbamol enantiomers using SIELC’s Cyralis CM chiral column. Cyralis CM is a cellulose-based chiral stationary phase (CSP) designed for enantiomeric separations, optical purity testing, chiral impurity analysis, and stereoisomer characterization in pharmaceutical, chemical, agrochemical, and fine chemical applications. For best results, the sample should be prepared fresh for analysis.
Methocarbamol can be retained and analyzed using the Cyralis CM stationary phase column. The analysis utilizes an isocratic method with a mobile phase consisting of sodium Hexane and Ethanol,. Detection is performed using UV.
Condition
| Column | Cyralis CM, 4.6 x 250 mm, 5 µm, 100 A, normal phase |
| Mobile Phase | Hexane/Ethano |
| Flow Rate | 1.0 mL/min |
| Detection | UV 220 nm |
| Resolution | 4.32 |
Description
| Class of Compounds | Drug |
| Analyzing Compounds | Methocarbamol |
Application Column
Cyralis CM
Column Diameter: 4.6 mm
Column Length: 250 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: normal phase
Separation of Methocarbamol on Newcrom R1 HPLC column
February 16, 2018
Methocarbamol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.