Fitusiran

Molecular FormulaC520H635F21N175Na44O309P43S6
Molecular Weight17215.34
Synonyms
  • ALN-AT3SC sodium; SAR439774 sodium

Applications:

Uv-Vis Spectrum of Fitusiran

March 9, 2026

Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Fitusiran check our HPLC Applications library

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.

Application Analytes:
Fitusiran
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Fitusiran on OligoMG Column

April 16, 2025

Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies

HPLC Method for Analysis Fitusiran on OligoMg Column by SIELC Technologies

HPLC Method for Analyzing Fitusiran on OligoMg Column by SIELC Technologies

Fitusiran is a relatively new therapeutic agent developed for the treatment of hemophilia A and B, including in patients with or without inhibitors.

Using SIELC’s newly introduced BIST™ method, this oligonucleotide can be retained on a OligoMg column. Using this new and unique analysis method, oligonucleotide can be separated, retained, and detected at 260 nm.

Please read more on oligonucleotides analysis by HPLC in our June 2024 newsletter.

Condition

ColumnOligoMg, 4.6 x 100 mm, 3 µm, 100 A, dual ended
Mobile PhaseGradient MeCN 60-10%, 10 min
Buffernone
Flow Rate1.0 ml/min
DetectionUV 260 nm

Description

Class of CompoundsDrug, RNA
Analyzing CompoundsFitusiran

Application Column

HPLC Column for Oligonucleotides

OligoMg

Column Diameter: 4.6 mm
Column Length: 100 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Fitusiran

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.