Cyclohexanecarboxylic acid

Cyclohexanecarboxylic acid structural formula

CAS Number98-89-5
Molecular FormulaC7H12O2
Molecular Weight128.172
InChI KeyNZNMSOFKMUBTKW-UHFFFAOYSA-N
LogP1.96
Synonyms
  • Cyclohexanecarboxylic acid
  • 98-89-5
  • 4-09-00-00016
  • Acide cyclohexanecarboxylique
  • acido ciclohexanocarboxilico
  • Benzoic acid, hexahydro-
  • Carboxycyclohexane
  • CYCLOHEXANCARBONSAEURE
  • Cyclohexancarbonsaure
  • Cyclohexanoic acid
  • Cyclohexylcarboxylic acid
  • Cyclohexylmethanoic acid
  • Hexahydrobenzoic acid
  • NSC 452
  • NSC 97391
  • NSC 97393
  • BRN 0970529
  • EINECS 202-711-3
  • FEMA No. 3531
  • UNII-H9VKD9VL18
  • 7549-42-0 (Calcium salt)
  • Cyclohexane-1-carboxylate
  • FEMA 3531
  • Hexahydro-Benzoic acid
  • Naphthenic acid
  • Naphthenoic acid
  • cyclohexanoic acid
  • cyclohexylformic acid

Applications:

Separation of Cyclohexanecarboxylic acid on Newcrom R1 HPLC column

2018-05-16
Separation of Cyclohexanecarboxylic acid on Newcrom R1 HPLC column

Cyclohexanecarboxylic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Analytes:
Cyclohexanecarboxylic acid
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.

Newcrom R1

The Newcrom columns are a family of reverse phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 columns are standard reverse phase columns with octyldecyl silane chains (C18) attached to porous silica. We have also designed a line of Newcrom R1 columns with a new outer design. This column and corresponding adapter entirely eliminate the need for any high-pressure fittings or tubing as well as minimizing all possible dead volumes. Furthermore, if a leak ever occurs in the high-pressure column inlet, the mobile phase is contained within the column adapter (no external leakage).

Select options