2,2,4-Trimethyl-1,3-pentanediol diisobutyrate

2,2,4-Trimethyl-1,3-pentanediol diisobutyrate structural formula

CAS Number6846-50-0
Molecular FormulaC16H30O4
Molecular Weight286.412
InChI KeyOMVSWZDEEGIJJI-UHFFFAOYSA-N
LogP4.22
Synonyms
  • 2,2,4-Trimethyl-1,3-pentanediol diisobutyrate
  • 2,2,4-Trimethylpentane-1,3-diyl bis(2-methylpropanoate)
  • Propanoic acid, 2-methyl-, 2,2-dimethyl-1-(1-methylethyl)-1,3-propanediyl ester
  • 6846-50-0
  • Propanoic acid, 2-methyl-, 2,2-dimethyl-1-(1-methylethyl)-1,3-propanediyl ester
  • 1-Isopropyl-2,2-dimethyltrimethylendiisobutyrat
  • 1-isopropyl-2,2-dimethyltrimethylene diisobutyrate
  • 2,2,4-TRIMETHYL-1,3-PENTANDIOL-DIISOBUTYRAT
  • 2,2,4-Trimethyl-1,3-pentanediol di(isopropylformate)
  • 2,2,4-Trimethyl-1,3-pentanediyl diisobutyrate
  • 2-Methylpropanoic acid 2,2-dimethyl-1-(1-methylethyl)-1,3-propanediyl ester
  • diisobutirato de 1-isopropil-2,2-dimetiltrimetileno
  • Diisobutyrate de 1-isopropyl-2,2-dimethyltrimethylene
  • DIISOBUTYRATE, 2,2,4-TRIMETHYL-1,3-PENTANEDIYL
  • Eastman TXIB
  • Isobutyric acid, 1-isopropyl-2,2-dimethyltrimethylene ester
  • Kodaflex TXIB
  • Kyowanol D
  • Kyowanol M
  • Optifilm Enhancer 300
  • Propanoic acid, 2-methyl-, 1,1'-[2,2-dimethyl-1-(1-methylethyl)-1,3-propanediyl] ester
  • PROPANOIC ACID, 2-METHYL-2,2-DIMETHYL-1-(1- METHYLETHYL)-1,3-PROPANEDIYL ESTER
  • Texanol isobutyrate
  • BRN 1878083
  • EINECS 229-934-9
  • 2,2,4-Trimethylpentanediol-1,3-diisobutyrate
  • UNII-4KZA479DWQ
  • 53490-81-6

Applications:

Separation of 2,2,4-Trimethyl-1,3-pentanediol diisobutyrate on Newcrom R1 HPLC column

February 16, 2018
Separation of 2,2,4-Trimethyl-1,3-pentanediol diisobutyrate on Newcrom C18 HPLC column

2,2,4-Trimethyl-1,3-pentanediol diisobutyrate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
2,2,4-Trimethyl-1,3-pentanediol diisobutyrate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.