Pentaerythritol tetraacrylate

Pentaerythritol tetraacrylate structural formula

CAS Number4986-89-4
Molecular FormulaC17H20O8
Molecular Weight352.339
InChI KeyKNSXNCFKSZZHEA-UHFFFAOYSA-N
LogP2.11
Synonyms
  • Pentaerythritol tetraacrylate
  • 2,2-Bis{[(prop-2-enoyl)oxy]methyl}propane-1,3-diyl diprop-2-enoate
  • 2-Propenoic acid, 2,2-bis[[(1-oxo-2-propen-1-yl)oxy]methyl]-1,3-propanediyl ester
  • 4986-89-4
  • 2-Propenoic acid, 2,2-bis[[(1-oxo-2-propenyl)oxy]methyl]-1,3-propanediyl ester
  • 2,2-Bis[[(1-oxoallyl)oxy]methyl]-1,3-propandiyldiacrylat
  • 2,2-bis[[(1-oxoallyl)oxy]methyl]-1,3-propanediyl diacrylate
  • 2-Propenoic acid 2,2-bis[[(1-oxo-2-propenyl)oxy]methyl]-1,3-propanediyl ester
  • 2-Propenoic acid, 1,1'-[2,2-bis[[(1-oxo-2-propen-1-yl)oxy]methyl]-1,3-propanediyl] ester
  • Acrylic acid, neopentanetetrayl ester
  • Acrylic acid, tetraester with pentaerythritol
  • Aronix M 450
  • Beam Set 710
  • diacrilato de 2,2-bis[[(1-oxoalil)oxi]metil]-1,3-propanodiilo
  • Diacrylate de 2,2-bis[[(1-oxoallyl)oxy]methyl]-1,3-propanediyle
  • Kayarad A-TMMT
  • Kayarad PET 40
  • Kayarad SR 295
  • Light Acrylate PE 4A
  • NK Ester A-TMMT
  • NK Ester A-YMMT
  • Pentaerythritol tetracrylate
  • Saret SR 295
  • Sartomer 295
  • Sartomer SR 295
  • Tetramethylolmethane tetraacrylate
  • Tetramethylolmethane tetracrylate
  • Viscoat 400
  • EINECS 225-644-1
  • UNII-50LIA3DGN1
  • 113674-04-7
  • 124538-16-5
  • 150315-46-1
  • 152992-37-5
  • 154303-16-9
  • 255831-13-1
  • 93218-05-4

Applications:

Separation of Pentaerythritol tetraacrylate on Newcrom R1 HPLC column

May 16, 2018
Separation of Pentaerythritol tetraacrylate on Newcrom R1 HPLC column

Pentaerythritol tetraacrylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Pentaerythritol tetraacrylate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.