| CAS Number | 102203-18-9 |
|---|---|
| Molecular Formula | C6H10N4S |
| Molecular Weight | 170.24 |
| InChI Key | PEHSVUKQDJULKE-UHFFFAOYSA-N |
| LogP | 0.2 |
| Synonyms |
|
Applications:
HPLC UV Method for Analysis of Imetit on Primesep A Column
June 9, 2026
HPLC Method for Analysis of [compound] on Primesep A Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Imetit.
Imetit is a histamine H3 receptor agonist with the chemical formula C6H10N4S. You can find detailed UV spectra of Imetit and information about its various lambda maxima by visiting the following link.
Imetit can be retained and analyzed using the Primesep A stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a [buffer] buffer. Detection is performed using UV.
Condition
| Column | Primesep A, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN – 80% |
| Buffer | H2SO4 – 0.4% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 200 |
| Limit Of Detection* | 130 ppb |
Description
| Class of Compounds | Histamine Receptor Agonist |
| Analyzing Compounds | Imetit |
Application Column
Primesep A
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Uv-Vis Spectrum of Imetit
June 9, 2026
Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Imetit check our HPLC Applications library
UV/Vis.: λmax: 203 nm
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The compound was dissolved in ethanol. This analysis was done with the mobile phase of hexane, IPA, and TFA.
HPLC UV Method for Analysis of Imetit on Chromni Column
June 9, 2026
HPLC Method for Analysis of [compound] on Chromni Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Imetit.
Imetit is a histamine H3 receptor agonist with the chemical formula C6H10N4S. You can find detailed UV spectra of Imetit and information about its various lambda maxima by visiting the following link.
Imetit can be retained and analyzed using the Chromni stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a [buffer] buffer. Detection is performed using UV.
Condition
| Column | Chromni, 4.6 x 150 mm, 3 µm, 100 A, dual ended |
| Mobile Phase | MeCN – 80% |
| Buffer | H2SO4 – 0.2% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 200 |
| Limit Of Detection* | 30 ppb |
Description
| Class of Compounds | Histamine Receptor Agonist |
| Analyzing Compounds | Imetit |
Application Column
Chromni
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 3 µm
Pore Size: 100 A
Column options: dual ended