Glycopyrrolate bromide

Glycopyrrolate bromide structural formula

CAS Number596-51-0
Molecular FormulaC19H28BrNO3
Molecular Weight398.341
InChI KeyVPNYRYCIDCJBOM-UHFFFAOYSA-M
LogP0.0950
Synonyms
  • Glycopyrrolate bromide
  • 3-{[Cyclopentyl(hydroxy)phenylacetyl]oxy}-1,1-dimethylpyrrolidin-1-ium bromide
  • Pyrrolidinium, 3-[(2-cyclopentyl-2-hydroxy-2-phenylacetyl)oxy]-1,1-dimethyl-, bromide (1:1)
  • 596-51-0
  • 3-{[Cyclopentyl(hydroxy)phenylacetyl]oxy}-1,1-dimethylpyrrolidin-1-ium bromide
  • Pyrrolidinium, 3-?[(2-?cyclopentyl-?2-?hydroxy-?2-?phenylacetyl)?oxy]?-?1,?1-?dimethyl-?, bromide (1:1)
  • AHR-504
  • Glycopyrrolate
  • Glycopyrrone bromide
  • Glycopyrronium bromide
  • NVA 237
  • Seebri
  • Pyrrolidinium, 3-[(cyclopentylhydroxyphenylacetyl)oxy]-1,1-dimethyl-, bromide
  • 1,1-Dimethyl-3-hydroxypyrrolidinium bromide alpha-cyclopentylmandelate
  • 3-Hydroxy-1,1-dimethylpyrrolidinium bromide alpha-cyclopentylmandelate
  • Asecryl
  • bromure de glycopyrronium
  • bromuro de glicopirronio
  • Copyrrolate
  • Gastrodyn
  • Glycopyrroniumbromid
  • Nodapton
  • NSC 250836
  • NSC 251251
  • NSC 251252
  • Pyrrolidinium, 3-hydroxy-1,1-dimethyl-, bromide, alpha-cyclopentylmandelate
  • Robanul
  • Robinul
  • Tarodyl
  • Tarodyn
  • beta-1-Methyl-3-pyrrolidyl-alpha-cyclopentylmandelate methobromide
  • EINECS 209-887-0
  • Glycopyrronii bromidum
  • Robinul forte
  • UNII-V92SO9WP2I
  • Cuvposa
  • 1-Methyl-3-pyrrolidyl alpha-phenylcyclopentaneglycolate methobromide
  • 3-Hydroxy-1,1-dimethylpyrrolidinium bromide alpha-cyclopentylmandelate

Applications:

Separation of Glycopyrrolate bromide on Newcrom R1 HPLC column

February 16, 2018
Separation of Glycopyrrolate bromide on Newcrom C18 HPLC column

Glycopyrrolate bromide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Glycopyrrolate bromide
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.