Ethanone, 2-bromo-1-(4-bromophenyl)-

Ethanone, 2-bromo-1-(4-bromophenyl)- structural formula

CAS Number99-73-0
Molecular FormulaC8H6Br2O
Molecular Weight277.943
InChI KeyFKJSFKCZZIXQIP-UHFFFAOYSA-N
LogP3.19
Synonyms
  • Ethanone, 2-bromo-1-(4-bromophenyl)-
  • 2-Bromo-1-(4-bromophenyl)ethan-1-one
  • 99-73-0
  • 4-07-00-00652
  • 2-(4-Bromophenyl)-2-oxoethyl bromide
  • 2,4'-Dibromacetophenon
  • 2,4'-dibromoacetofenona
  • 2,4'-Dibromoacetophenone
  • 2-Bromo-1-(4-bromophenyl)-1-ethanone
  • 2-Bromo-1-(4-bromophenyl)ethanone
  • 2-Bromo-4'-bromoacetophenone
  • 4,?-Dibromoacetophenone
  • 4-Bromo(bromoacetyl)benzene
  • 4-Bromophenacyl bromide
  • Acetophenone, 2,4'-dibromo-
  • Bromomethyl 4-bromophenyl ketone
  • Bromomethyl p-bromophenyl ketone
  • NSC 6224
  • p,?-Dibromoacetophenone
  • p-Bromophenacyl bromide
  • ?,4'-Dibromoacetophenone
  • ?,4-Dibromoacetophenone
  • ?,p-Dibromoacetophenone
  • ?-4-Dibromoacetophenone
  • ?-Bromo-4-bromoacetophenone
  • ?-Bromo-p-bromoacetophenone
  • ?,4-Dibromoacetophenone
  • BRN 0607604
  • p-Bromophenacyl-8
  • alpha,p-Dibromoacetophenone
  • alpha,4-Dibromoacetophenone
  • EINECS 202-783-6
  • Parabromophenacyl bromide
  • UNII-PN0FRW1G4Z

Applications:

Separation of Ethanone, 2-bromo-1-(4-bromophenyl)- on Newcrom R1 HPLC column

February 16, 2018
Separation of Ethanone, 2-bromo-1-(4-bromophenyl)- on Newcrom C18 HPLC column

Ethanone, 2-bromo-1-(4-bromophenyl)- can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Ethanone, 2-bromo-1-(4-bromophenyl)-
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.