Dinoseb

Dinoseb structural formula

CAS Number88-85-7
Molecular FormulaC10H12N2O5
Molecular Weight240.215
InChI KeyOWZPCEFYPSAJFR-UHFFFAOYSA-N
LogP3.56
Synonyms
  • Dinoseb
  • 2-(Butan-2-yl)-4,6-dinitrophenol
  • Phenol, 2-(1-methylpropyl)-4,6-dinitro-
  • 88-85-7
  • Phenol, 2-(1-methylpropyl)-4,6-dinitro-
  • Dinoseb acid
  • 2-sec-Butyl-4,6-dinitrophenol
  • 2-(1-Methylpropyl)-4,6-dinitrophenol
  • 2,4-Dinitro-6-(1-methylpropyl)phenol
  • 2,4-Dinitro-6-sec-butylphenol
  • 4,6-Dinitro-2-(1-methyl-n-propyl)phenol
  • 4,6-Dinitro-2-(2-butyl)phenol
  • 4,6-Dinitro-2-sec-butylphenol
  • 4,6-Dinitro-o-sec-butylphenol
  • 6-sec-Butyl-2,4-dinitrophenol
  • Blaartox
  • Butaphen
  • Butaphene
  • Chemox P.E.
  • Desicoil
  • Dibutox
  • Dibutox 20CE
  • Dinosebe
  • Dow General
  • Hivertox
  • Liro DNBP
  • NSC 202753
  • Phenol, 2-sec-butyl-4,6-dinitro-
  • Premerge
  • Super Kabrol
  • UN 2779
  • UN 2780
  • UN 3013
  • Basanite
  • BRN 3211812
  • Caswell No. 392DD
  • Dinitrall
  • 4,6-Dinitro-2-(1-methyl-propyl)phenol
  • Dinitro-ortho-sec-butyl phenol
  • Dow General Weed Killer
  • Dow Selective Weed Killer
  • EINECS 201-861-7
  • Elgetol 318
  • EPA Pesticide Chemical Code 037505
  • Gebutox
  • Gebutox; knox-weed
  • Hel-Fire
  • Kiloseb
  • Knox-weed
  • Nitropone C
  • Phenotan
  • RCRA waste number P020
  • Subitex
  • Unicrop DNBP
  • Vertac Dinitro Weed Killer
  • Vertac General Weed Killer
  • Vertac Selective Weed Killer
  • 4,6-Dinitro-2-sec.butylfenol
  • 6-(1-Methyl-propyl)-2,4-dinitrofenol
  • 6-(1-Metil-propil)-2,4-dinitro-fenolo
  • UNII-YD44ZEM22M
  • 152212-20-9
  • 39403-80-0

Applications:

Separation of Dinoseb on Newcrom R1 HPLC column

February 16, 2018
Separation of Dinoseb on Newcrom C18 HPLC column

Dinoseb can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Dinoseb
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.