Diclobutrazol Separation on Primesep and Obelisc HPLC Columns

Diclobutrazol is a fungicide based on 1,2,4-triazol. It is used in production of coffee and various cereal grains. Primesep 100 Obelisc R were used to separate diclobutrazol. Primesep 100 is a mixed-mode column which uses embedded ion-pairing groups and Obelisc can fine tune separations using both a long hydrophobic chain and ionic groups. Method is LC/MS compatible and can be used for many pesticides.

Condition 1

Column Obelisc R, 2.1x150 mm, 5 µm, 100A
Mobile Phase Gradient MeCN - 25-70%, 15 min
Buffer Gradient AmAc pH 3.0- 30-60 mM, 15 min
Flow Rate 0.4 ml/min
Detection UV, 270 nm
 

Condition 2

Column Obelisc R, 2.1x150 mm, 5 µm, 100A
Mobile Phase Gradient MeCN - 10-70%, 15 min
Buffer Gradient AmAc pH 3.0- 20-60 mM, 15 min
Flow Rate 0.4 ml/min
Detection UV, 270 nm
 

Condition 3

Column Primesep 100, 2.1x150 mm, 5 µm, 100A
Mobile Phase Gradient MeCN - 10-70%, 15 min
Buffer Gradient AmAc pH 3.0- 20-60 mM, 15 min
Flow Rate 0.4 ml/min
Detection UV, 270 nm
 

Description

Class of Compounds  Insecticide, Herbicide, Fungicide,  Hydrophobic, Ionizable
Analyzing Compounds Diclobutrazol
 
SIELC Technologies usually develops more than one method for each compound on our website. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound of interest.
Application Analytes:
Diclobutrazol

Application Detection:
UV Detection