6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid

6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid structural formula

CAS Number80584-91-4
Molecular FormulaC21H36N6O6
Molecular Weight468.555
InChI KeyBKKWPPMEXIXECW-UHFFFAOYSA-N
LogP1.99
Synonyms
  • 6,6',6''-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid
  • Hexanoic acid, 6,6',6''-(1,3,5-triazine-2,4,6-triyltriimino)tris-
  • 80584-91-4
  • Hexanoic acid, 6,6',6''-(1,3,5-triazine-2,4,6-triyltriimino)tris-
  • Hexanoic acid, 6,6',6''-(s-triazine-2,4,6-triyltriimino)tri-
  • 6,6',6''-(1,3,5-Triazine-2,4,6-triyltriimino)tris[hexanoic acid]
  • 1,3,5-Triazine-2,4,6-triaminocaproic acid
  • 6,6',6''-(1,3,5-Triazine-2,4,6-triyltriimino)trihexanoic acid
  • 6,6',6''-(1,3,5-Triazine-2,4,6-triyltriimino)tris(hexanoic acid)
  • Belcor 593
  • Irgacor L 190 Plus
  • L 190 Plus
  • Acide 6,6',6''-(1,3,5-triazine-2,4,6-triyltriimino)trihexanoique
  • 6,6',6''-(1,3,5-triazine-2,4,6-triyltriimino)trihexanoic acid
  • 6,6',6''-(1,3,5-triazin-2,4,6-triyltriimino)trihexansaure
  • acido 6,6',6''-(1,3,5-triazina-2,4,6-triiltriimino)trihexanoico
  • 6,6',6''-(1,3,5-Triazine-2,4,6-triyltriimino)trishexanoic acid
  • Acido hexanoico, 6,6',6''-(1,3,5-triazina-2,4,6-triiltriimino)tris-
  • Belcor 590
  • Irgacor 190
  • Irgacor L 190
  • EINECS 279-505-5
  • 109075-25-4

Applications:

Separation of 6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid on Newcrom R1 HPLC column

May 16, 2018
Separation of 6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid on Newcrom R1 HPLC column

6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
6,6’,6’’-(1,3,5-Triazine-2,4,6-triyltriazanediyl)trihexanoic acid
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.