2,4-Diaminoanisole sulfate

2,4-Diaminoanisole sulfate structural formula

CAS Number39156-41-7
Molecular FormulaC7H12N2O5S
Molecular Weight236.241
InChI KeyFDJQHYWUHGBBTO-UHFFFAOYSA-N
LogP0.0677
Synonyms
  • 2,4-Diaminoanisole sulfate
  • Sulfuric acid--4-methoxybenzene-1,3-diamine (1/1)
  • 1,3-Benzenediamine, 4-methoxy-, sulfate (1:1)
  • 39156-41-7
  • C.I. Oxidation Base 12A
  • Anisole, 2,4-diamino-, hydrogen sulfate
  • Anisole, 2,4-diamino-, sulfate
  • BASF Ursol SLA
  • CI Oxidation Base 12A
  • 2,4-DAA sulfate
  • 2,4-Diaminoanisile sulfate
  • 2,4-Diamino-anisol sulphate
  • 2,4-Diaminoanisole sulfate trihydrate
  • 2,4-Diaminoanisole sulphate
  • 1,3-Diamino-4-methoxybenzene sulphate
  • 2,4-Diamino-1-methoxybenzene sulphate
  • 2,4-Diaminosole sulphate
  • Durafur Brown MN
  • EINECS 254-323-9
  • Fouramine BA
  • Fourrine 76
  • Fourrine SLA
  • Furro SLA
  • 4-Methoxy-1,3-benzenediamine sulfate (1:1)
  • 4-Methoxy-1,3-benzenediamine sulphate
  • 4-Methoxy-m-phenylenediamine sulfate
  • p-Methoxy-m-phenylenediamine sulphate
  • 4-Methoxy-m-phenylenediamine sulphate
  • Nako TSA
  • NCI-C01989
  • Oxidation Base 12A
  • Pelagol BA
  • Pelagol Grey
  • Pelagol Grey SLA
  • Pelagol SLA
  • Renal SLA
  • Ursol SLA
  • Zoba SLE
  • UNII-N4U4U64VRF
  • 108066-98-4

Applications:

Separation of 2,4-Diaminoanisole sulfate on Newcrom R1 HPLC column

February 19, 2018
Separation of 2,4-Diaminoanisole sulfate on Newcrom C18 HPLC column

2,4-Diaminoanisole sulfate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
2,4-Diaminoanisole sulfate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us before ordering the column as there may be a more suitable column alternative by either e-mail: support@sielc.com or by phone: 847-229-2629.