Ethyl red

Ethyl_red

CAS Number76058-33-8
Molecular FormulaC17H19N3O2
Molecular Weight297.358
InChI KeyHBRCDTRQDHMTDA-UHFFFAOYSA-N
LogP4.1
Synonyms
  • Ethyl red
  • 76058-33-8
  • UNII-FTV19WGM7I
  • DIETHYL RED
  • FTV19WGM7I
  • 4-Diethylaminoazobenzene-2'-carboxylic acid
  • HBRCDTRQDHMTDA-UHFFFAOYSA-N
  • Benzoic acid, 2-[[4-(diethylamino)phenyl]azo]-
  • 2-{2-[4-(diethylamino)phenyl]diazen-1-yl}benzoic acid
  • 2-[[4-(diethylamino)phenyl]diazenyl]benzoic acid
  • 2-{[4-(diethylamino)phenyl]diazenyl}benzoic acid
  • Benzoic acid, 2-((4-(diethylamino)phenyl)azo)-
  • Ethyl Red Indicator

Applications:

UV-Vis Spectrum of Ethyl Red

July 16, 2024
UV-Vis Spectrum of Ethyl Red. Absorption Maxima: 218 nm, 292 nm, 520 nm.

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.

Application Analytes:
Ethyl red
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Separation of Methyl Red and Ethyl Red on Primesep 100 Column

December 22, 2022

High Performance Liquid Chromatography (HPLC) Method for Separation of Methyl Red and Ethyl Red on Primesep 100 by SIELC Technologies.

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Separation of Меthyl Red and Ethyl Red on Primesep 100 Column
HPLC Method for Separation of Меthyl Red and Ethyl Red on Primesep 100 Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Separation of Меthyl Red and Ethyl Red

Methyl Red is a dark-red, single-charged basic dye that turns a deep red in acidic (low pH) solutions. Ethyl Red is a magenta-colored, single-charged basic dye. These two basic dyes can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be detected in the Visible spectrum at 520 nm.

Condition

ColumnPrimesep 100, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN/H2O – 60/40%
BufferH3PO4 – 0.2%
Flow Rate1.0 ml/min
DetectionVis, 520 nm
Peak Retention Time6.19, 7.28 min

Description

Class of CompoundsDyes
Analyzing CompoundsМеthyl red, Ethyl red

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ethyl red
Methyl Red
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Pararosaniline and Ethyl Red on Primesep 100 Column

December 7, 2022

High Performance Liquid Chromatography (HPLC) Method for Analysis of Pararosaniline and Ethyl Red on Primesep 100 by SIELC Technologies.

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of Pararosaniline and Ethyl Red on Primesep 100 Column
HPLC Method for Analysis of Pararosaniline and Ethyl Red on Primesep 100 Column by SIELC Technologies

Pararosaniline (Basic Red 9) is a popular basic magenta dye and part of the triarylmethane family of dyes. Ethyl Red is a similarly-colored, single-charged basic dye. These two basic dyes can be separated, retained, and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be detected in the visible regime at 520 nm.

High Performance Liquid Chromatography (HPLC) Method for Analyses of Pararosaniline and Ethyl red

Condition

ColumnPrimesep 100, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN/H2O – 50/50%
BufferH3PO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV, 520 nm
Peak Retention Time10.82 min

Description

Class of CompoundsDyes
Analyzing CompoundsPararosaniline, Ethyl red

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ethyl red
Pararosaniline Hydrochloride
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Ethyl Red on Primesep 100 Column

December 7, 2022

High Performance Liquid Chromatography (HPLC) Method for Analysis of Ethyl Red on Primesep 100 by SIELC Technologies.

Separation type: Liquid Chromatography Mixed-mode

HPLC Method for Analysis of Ethyl Red on Primesep 100 Column
HPLC Method for Analysis of Ethyl Red on Primesep 100 Column by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analyses of Ethyl red

Ethyl red can be retained and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple isocratic mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer.  This analysis method can be UV detected at 600 nm with high resolution and peak symmetry.

Condition

ColumnPrimesep 100, 4.6×150 mm, 5 µm, 100A
Mobile PhaseMeCN/H2O – 80/20%
BufferH3PO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV, 550 nm
Peak Retention Time3.82 min

Description

Class of CompoundsDyes
Analyzing CompoundsEthyl red

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Ethyl red
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Ethyl red

June 1, 2018

HPLC Method for Analysis of Ethyl red

 

Condition

Column Newcrom R1 3.2×100 mm, 3 µm, 100A
Mobile Phase MeCN/H2O – 60/10%
Buffer H3PO4 – 0.1%
Flow Rate 0.5 ml/min
Detection UV, 250 nm

 

Description

Class of Compounds
Dye, Hydrophobic
Analyzing Compounds Ethyl red

 

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Ethyl red
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.