Chlophedianol

Chlophedianol structural formula

CAS Number791-35-5
Molecular FormulaC17H20ClNO
Molecular Weight289.800
InChI KeyWRCHFMBCVFFYEQ-UHFFFAOYSA-N
LogP3.24
Synonyms
  • Chlophedianol
  • 1-(2-Chlorophenyl)-3-(dimethylamino)-1-phenylpropan-1-ol
  • Benzenemethanol, 2-chloro-alpha-[2-(dimethylamino)ethyl]-alpha-phenyl-
  • 791-35-5
  • Benzenemethanol, 2-chloro-?-[2-(dimethylamino)ethyl]-?-phenyl-
  • (.+-.)-Chlophedianol
  • 1-o-Chlorophenyl-1-phenyl-3-dimethylamino-1-propanol
  • 1-o-Chlorophenyl-3-dimethylamino-1-phenylpropan-1-ol
  • 1-Phenyl-1-(o-chlorophenyl)-3-dimethylaminopropanol
  • 1-Phenyl-1-o-chlorophenyl-3-(dimethylamino)-1-propanol
  • 2-Chloro-?-(2-dimethylaminoethyl)benzhydrol
  • Benzhydrol, 2-chloro-?-[2-(dimethylamino)ethyl]-
  • Calmotusin
  • clofedano
  • Clofedanol
  • NSC 113595
  • Tussistop
  • ?-(Dimethylaminoethyl)-o-chlorobenzhydrol
  • BRN 2813922
  • Chlofedanol
  • 2-Chloro-alpha-(2-(dimethylamino)ethyl)benzhydrol
  • Clophedianol base
  • alpha-(Dimethylaminoethyl)-o-chlorobenzhydrol
  • EINECS 212-340-9
  • SL 501 base
  • Ulo base
  • 1-(2-Chlorophenyl)-1-phenyl-3-dimethylaminopropanol
  • 2-Cloro-alpha-(2-dimetilaminoetil)-benzidrolo
  • Clofedanolum
  • Clofedianolo
  • UNII-42C50P12AP

Applications:

Separation of Chlophedianol on Newcrom R1 HPLC column

February 16, 2018
Separation of Chlophedianol on Newcrom C18 HPLC column

Chlophedianol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Chlophedianol
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.