CAS Number | 54-47-7 |
---|---|
Molecular Formula | C8H10NO6P |
Molecular Weight | 247.14 |
InChI Key | NGVDGCNFYWLIFO-UHFFFAOYSA-N |
LogP | -1.1 |
Synonyms |
|
Applications:
HPLC Method for Analysis of Water-Soluble Vitamins (B1, B2, B3, B6) on Primesep 100 Column
August 28, 2024
High Performance Liquid Chromatography (HPLC) Method for Analysis of Water-Soluble Vitamins (B1, B2, B3, B6) on Primesep 100 by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Vitamin B1 (Thiamine), Vitamin B2 (Riboflavin), Nicotinamide, Vitamin B6 (Pyridoxine), Pyridoxamine, Pyridoxal Phosphate
Water-Soluble Vitamins (B1, B2, B3, B6) can be retained, separated and analyzed using a Primesep 100 mixed-mode stationary phase column. The analysis employs an gradient method with a simple mobile phase comprising water, acetonitrile (MeCN), and sulfuric acid as a buffer. This method allows for detection using UV 300 nm.
You can find detailed UV spectra of Vitamin B1 (Thiamine), Vitamin B2 (Riboflavin), Nicotinamide, Vitamin B6 (Pyridoxine), Pyridoxamine, Pyridoxal Phosphate and information about its various lambda maxima by visiting the following links: Vitamins (B1, B2, B3, B6)
Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN – 10% |
Buffer | Gradient H2SO4 -0.1-0.5% in 10 min |
Flow Rate | 1.0 ml/min |
Detection | UV 270 nm |
Class of Compounds | Water-Soluble Vitamins (B1, B2, B3, B6) |
Analyzing Compounds | Vitamin B1 (Thiamine), Vitamin B2 (Riboflavin), Nicotinamide, Vitamin B6 (Pyridoxine), Pyridoxamine, Pyridoxal Phosphate |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Pyridoxal Phosphate
Pyridoxamine
Vitamin B1 (Thiamine)
Vitamin B2 (Riboflavin)
Vitamin B6 (Pyridoxine)
HPLC Method for Analysis of Thiamine Pyrophosphate and Pyridoxal Phosphate on Primesep SB Column
July 11, 2017
Column | Primesep SB, 4.6×50 mm, 5 µm, 100A |
Mobile Phase | MeCN |
Buffer | AmFm pH 3.0 |
Flow Rate | 1.0 ml/min |
Detection | UV, 290 nm |
Class of Compounds |
Hydrophilic, Ionizable |
Analyzing Compounds | Thiamine Pyrophosphate, Pyridoxal Phosphate |
Application Column
Primesep SB
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsThiamine diphosphate (Thiamine pyrophosphate)