Hydrocortisone

Hydrocortisone structural formula

CAS Number50-23-7
Molecular FormulaC21H30O5
Molecular Weight362.467
InChI KeyJYGXADMDTFJGBT-VWUMJDOOSA-N
LogP1.61
Synonyms
  • Hydrocortisone
  • (11beta)-11,17,21-Trihydroxypregn-4-ene-3,20-dione
  • Pregn-4-ene-3,20-dione, 11,17,21-trihydroxy-, (11beta)-
  • 50-23-7
  • Cortisol
  • CORT
  • Pregn-4-ene-3,20-dione, 11,17,21-trihydroxy-, (11β)-
  • (11β)-11,17,21-Trihydroxypregn-4-ene-3,20-dione
  • 11β,17,21-Trihydroxypregn-4-ene-3,20-dione
  • 11β,17,21-Trihydroxyprogesterone
  • 11β,17α,21-Trihydroxypregn-4-ene-3,20-dione
  • 11β-Hydroxycortisone
  • 17-Hydroxycorticosterone
  • 17α-Hydroxycorticosterone
  • 4-Pregnene-11β,17α,21-triol-3,20-dione
  • Acticort
  • Aeroseb HC
  • Ala-Cort
  • Anti-inflammatory hormone
  • CaldeCort Spray
  • Cetacort
  • Cobadex
  • Cortanal
  • Cort-Dome
  • Cortenema
  • Corticreme
  • Cortifan
  • Cortiment
  • Cortispray
  • Cortonema
  • Cortril
  • Dermacort
  • Dermocortal
  • Dermolate
  • Dihydrocostisone
  • Dioderm
  • Domolene-HC
  • Efcorbin
  • Efcortelan
  • Eldecort
  • Epiderm H
  • Esiderm H
  • Evacort
  • Ficortril
  • Genacort
  • Heb-Cort
  • Hidro-Colisona
  • hidrocortisona
  • Hycortol
  • Hycortole
  • Hydracort
  • Hydrasson
  • Hydro-Adreson
  • Hydrocort
  • Hydrocortal
  • Hydrocorticosterone
  • Hydrocortison
  • Hydrocortisyl
  • Hydrocortone
  • Hydroskin
  • Hytone lotion
  • Incortin-H
  • Kendall's compound F
  • Lacticare HC
  • Medicort
  • Mildison
  • NSC 10483
  • Nutracort
  • Otosone-F
  • Penecort
  • Permicort
  • Polcort H
  • Reichstein's substance M
  • Scheroson F
  • Synacort
  • Tarcortin
  • Texacort
  • Texacort lotion 25
  • Timocort
  • Traumaide
  • Zenoxone
  • EINECS 200-020-1
  • Eldercort
  • 11-beta-Hydrocortisone
  • 17alpha-Hydroxycorticosterone
  • Pregn-4-ene-3,20-dione, 11beta,17,21-trihydroxy-
  • Pregn-4-ene-3,20-dione, 11,17,21-trihydroxy-, (11-beta)-
  • 4-Pregnene-11beta,17alpha,21-triol-3,20-dione
  • 11beta,17,21-Trihydroxypregn-4-ene-3,20-dione
  • Algicirtis
  • Dermaspray
  • Remederm HC
  • Colocort
  • Balneol-HC
  • Beta-HC
  • Flexicort
  • Glycort
  • Hydrocortisone in absorbase
  • Hydro-RX
  • Nogenic HC
  • Stie-Cort
  • Anucort
  • Anucort-HC
  • Proctozone HC
  • Rectasol-HC
  • Scalp-Cort
  • UNII-WI4X0X7BPJ
  • Proctosol-HC
  • (11beta)-11,17,21-trihydroxypregn-4-ene-3,20-dione
  • (1S,2R,10S,11S,14S,15S,17S)-14,17-dihydroxy-14-(2-hydroxyacetyl)-2,15-dimethyltetracyclo[8.7.0.02,7.011,15]heptadec-6-en-5-one
  • 11-Hydrocortisone
  • 11-beta-Hydrocortisone
  • 11-beta-Hydroxycortisone
  • 11a-Hydroxycorticosterone
  • 11alpha-Hydroxycorticosterone
  • 11b,17,21-Trihydroxyprogesterone
  • 11b-Hydrocortisone
  • 11b-Hydroxycortisone
  • 11beta,17,21-Trihydroxyprogesterone
  • 11beta,17alpha,21-trihydroxy-4-pregnene-3,20-dione
  • 11beta-Hydroxycortisone
  • 11beta-hydrocortisone
  • 17a-Hydroxycorticosterone
  • 17alpha-Hydroxycorticosterone
  • 4-Pregnene-11alpha,21-triol 3,20-dione
  • 4-Pregnene-11b,17a,21-triol-3,20-dione
  • 4-pregnen-11beta,17alpha,21-triol-3,20-dione
  • Aeroseb-HC
  • Ala-Scalp
  • Alacort
  • Algicirtis
  • Alphaderm
  • Amberin
  • Anflam
  • Aquacort
  • Aquanil HC
  • Barseb HC
  • Basan-Corti
  • Chronocort
  • Clear aid
  • Cleiton
  • Compound F
  • Cor-Tar-Quin
  • Cort-Quin
  • Cortesal
  • Cortifoam
  • Cortisol alcohol
  • Cortisolonum
  • Cortisporin
  • Cortisporin Otico
  • Cortizol
  • Cortolotion
  • Cortonema
  • Cortoxide
  • Cremesone
  • Cremicort-H
  • Cutisol
  • Delacort
  • Derm-Aid
  • Dermil
  • Dome-cort
  • Drotic
  • Ef corlin
  • Efcortelin
  • Eldercort
  • Epicort
  • Fiocortril
  • Foille Insetti
  • Gyno-Cortisone
  • H-Cort
  • HC
  • Heb Cort
  • Hidalone
  • Hycort
  • Hycortol
  • Hydro-colisona
  • Hydrocortisone alcohol
  • Hydrocortisone base
  • Hydrocortisone free alcohol
  • Hydrocortisonum
  • Hydrocortistab
  • Hydroxycortisone
  • Hysone
  • Hytisone
  • Hytone
  • Idrocortisone
  • Incortin-hydrogen
  • Komed HC
  • Kyypakkaus
  • Lacticare-HC
  • Lactisona
  • Lubricort
  • Maintasone
  • Meusicort
  • Milliderm
  • Neo-Cort-Dome
  • Neosporin-H Ear
  • Nystaform-HC
  • Optef
  • Otalgine
  • Otic-Neo-Cort-Dome
  • Otobiotic
  • Otocort
  • Pediotic Suspension
  • Preparation H Hydrocortisone Cream
  • Prepcort
  • Prestwick_265
  • Prevex HC
  • Proctocort
  • Proctofoam
  • Protocort
  • Racet
  • Rectoid
  • Remederm HC
  • Sanatison
  • Scalpicin Capilar
  • Schericur
  • Sigmacort
  • Signef
  • Stiefcorcil
  • Systral Hydrocort
  • Topicort
  • Transderma H
  • Uniderm
  • Vioform-Hydrocortisone
  • VoSol HC
  • Vytone
  • 1050676-88-4
  • 8056-08-4
  • 80562-38-5
  • 8063-42-1

Applications:

HPLC Method for Simultaneous Determination of Acyclovir and Hydrocortisone on Primesep 100 Column

August 31, 2022

Separation type: Liquid Chromatography Mixed-mode

 

 

High Performance Liquid Chromatography (HPLC) Method for Analysis of Acyclovir and Hydrocortisone

Acyclovir is used to treat viral infections caused by a group of viruses called herpes simplex viruses. These infections include oral and genital herpes, as well as shingles. It can also be used to treat chickenpox in children. Hydrocortisone, or cortisol, is a common corticosteroid used to treat a wide variety of ailments, including high blood calcium, arthritis, dermatitis, and asthma, among others. Both of these drugs can be separated, retained, and analyzed on a Primesep 100 mixed-mode column using an isocratic analytical method with a simple isocratic mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be UV detected at 254 nm with high resolution and peak symmetry.

Condition

Column Primesep 100, 3.2×150 mm, 5 µm, 100A
Mobile Phase MeCN – 35%
Buffer H2SO4 – 0.1%
Flow Rate 0.5 ml/min
Detection UV 254 nm

 

Description

Class of Compounds Drug
Analyzing Compounds Acyclovir and Hydrocortisone

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Acyclovir
Hydrocortisone
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Hydrocortisone

May 3, 2016

Chr_1055




Hydrocortisone, also known as 11β,17α,21-trihydroxypregn-4-ene-3,20-dione, is a corticosteroid, is similar to a natural hormone produced by your adrenal glands. It is used to treat certain forms of arthritis as well various skin conditions (redness, swelling, and itching). Primesep 200, a reverse phase column, contains embedded acidic ionizable groups and can retain Hydrocortisone. The method is UV compatible and can be used as a general approach for analyzing similar compounds.

Application Column

Primesep 200

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
HPLC Ananlysis of Hydrocortisone
HPLC Method for Analysis of Hydrocortisone
HPLC Separation of Hydrocortisone and Hydrocortisone’s Degradation Products
Hydrocortisone

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Ananlysis of Hydrocortisone

July 31, 2015

 

Hydrocortisone is the drug form of the steroid hormone cortisol. Cortisol is an important biological molecule which affects blood sugar, metabolism and the immune system. It was retained on the reverse-phase column Legacy L1. Comparisons of Legacy L1 and Phenomenex columns are available by request.

Condition

Column Legacy L1, 4.6×250 mm, 5 µm, 100A
Mobile Phase MeCN – 40%
Buffer NaH2PO4 pH 2.5 – 10 mM
Flow Rate 1.0 ml/min
Detection UV, 210 nm

Description

Class of Compounds
Hormone,   Hydrophobic, Ionizable
Analyzing Compounds Hydrocortisone

&

Application Column

SIELC Legacy L1 HPLC column

Legacy L1

SIELC's family of Legacy columns is based on the United States Pharmacopeia's (USP) published chromatographic methods and procedures. Numerous brands have columns used in USP reference standards and methods. USP has created various designations to group together columns with similar types of packing and properties in the solid phase. SIELC's Legacy columns adhere to these strict requirements and properties, allowing you to easily replace older columns that are no longer available without needing to significantly modify your method or SOPs.

Select options
Application Analytes:
Hydrocortisone
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

USP Methods for the Analysis of Hydrocortisone on a Legacy L1 Column

June 21, 2012

 

Application Notes: Hydrocortisone is a naturally occurring hormone released during times of stress. Hydrocortisone has been synthesized and is used to treat diseases such as allergic reactions and skin conditions. According to the USP methods, hydrocortisone contains not less than 97 percent and not more than 102 percent of hydrocortisone calculated on the dried basis. The USP HPLC method for the separation of hydrocortisone was developed on Legacy L1 column according to the US Pharmacopeia methodology. L1 classification is assigned to reversed-phase HPLC column containing C18 ligand. Support for the material is spherical silica gel with particles size 3-10 um and pore size of 100-120A.

Application Columns: Legacy L1 C18 HPLC column

Application compounds: Hydrocortisone

Mobile phase: MeCN/H2O 25:75

Detection technique: UV

Reference: USP30: NF35

Condition

Column Legacy L1, 4.6×150 mm, 5 µm, 100A
Mobile Phase NaH2PO4 pH 7.0/MeCN 88/12
Buffer NaH2PO4
Flow Rate 1.0 ml/min
Detection UV, 254 nm

 

Description

Class of Compounds
Drug, Antibiotics, Hydrophobic, Ionizable
Analyzing Compounds Nitrofurantoin

 

Application Column

SIELC Legacy L1 HPLC column

Legacy L1

SIELC's family of Legacy columns is based on the United States Pharmacopeia's (USP) published chromatographic methods and procedures. Numerous brands have columns used in USP reference standards and methods. USP has created various designations to group together columns with similar types of packing and properties in the solid phase. SIELC's Legacy columns adhere to these strict requirements and properties, allowing you to easily replace older columns that are no longer available without needing to significantly modify your method or SOPs.

Select options
Application Analytes:
Hydrocortisone

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Hydrocortisone and Hydrocortisone’s Degradation Products

March 27, 2011


Cortisol (hydrocortisone) is a steroid hormone produced by the adrenal gland. Hydrocortisone is a hydrophobic neutral compound with some polar groups in its structure. Several Primesep mixed-mode columns were used for separation of hydrocortisone and its degradation products. Each column showed a different selectivity for separation, which attributed to different polar-embedded groups on Primesep 100 and Primesep D columns. Both columns can be used for degradation studies of various hydrophobic compounds.

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options

Primesep D

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
HPLC Method for Analysis of Hydrocortisone
Hydrocortisone

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.