CAS Number | 133-07-3 |
---|---|
Molecular Formula | C9H4Cl3NO2S |
Molecular Weight | 296.550 |
InChI Key | HKIOYBQGHSTUDB-UHFFFAOYSA-N |
LogP | 2.85 |
Synonyms |
|
Applications:
HPLC Separation of Folpet on Obelisc and Primesep Mixed-Mode Obelisc R Column
June 11, 2020
Column | Obelisc R, 2.1 x 150 mm, 5 µm, 100 A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 4,5- 20-50 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 250 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Folpet |
Application Column
Obelisc R
Column Diameter: 2.1 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Separation of Pesticides, Herbicides, Fungicides and Insecticides on Newcrom BH Column
May 22, 2020
Herbicides are used to control unwanted plants, they are also known as weedkillers. Insecticides are used to kill insects. Fungicides are used to kill parasitic fungi. Pesticide is a more generic term that includes herbicides, fungicides and insecticides in its definition. All are heavily used in agriculture. By using HPLC, many different pesticides can be separated and their retention characteristics controlled using the Newcrom BH mixed-mode column. It can be used with different organic media such as acetonitrile (ACN) or methanol (MeOH). By varying the concentration of organic modifier and using different buffers like sulfuric acid (H2SO4), ammonium formate (AmFm), or formic acid, separation of desired pesticides can be achieved.
Column | Newcrom BH, 3.2×100 mm, 5 µm, 100A |
Mobile Phase | MeCN, MeOH |
Buffer | H2SO4, Formic acid, AmFm pH 3.0 |
Flow Rate | 0.6 ml/min |
Detection | UV 275 nm |
Class of Compounds | Pesticides, Herbicides, Fungicides, Insecticides |
Analyzing Compounds | Monocrotophos, Metribuzin, Bromacil, Carbofuran, 4-Chlorophenoxyacetic acid, Bentazone, Folpet, Fenthion, Fenvalerate, Metrabuzin, Carbofuran, Atrazine, Parathion –methyl, MCPA, Clopyralid, Dicamba, Benthazon, Simazine, Diuron, MCPB, Mecoprop, 4-Chlorophenoxyacetic acid,2,4,5-T |
Application Column
Newcrom BH
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options4-CPA
Atrazine
Bentazone-sodium
Carbofuran
Clopyralid
Dicamba
Diuron
Fenvalerate
Folpet
MCPA
MCPB
Mecoprop
Methyl parathion
Metribuzin
Monocrotophos
Simazine
Folpet Analysis on Primesep 100 and Obelisc R HPLC Columns
September 14, 2015
Folpet is a fungicide which is used to prevent a variety of fungal infections such as apple scab, cherry leaf spot, rose black spot, and rose mildew. Folpet was one of many pesticides studied by the EURL-SRM, a proficiency test for single residue methods developed by the European Union Reference Laboratory. Folpet was retained and separated from impurities with Obelisc R and Primesep 100 columns. Primesep 100 contains embedded acidic ion-pairing groups and Obelisc R contains embedded ionic and hydrophobic groups which can assist in fine tuning separations. Method can be used for dozens of other pesticides and is LC/MS compatible.
Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 25-70%, 15 min |
Buffer | Gradient AmAc pH 3.0- 30-60 mM, 15 min |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min |
Buffer | Gradient AmAc pH 3.0- 20-60 mM, 15 min |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Column | Primesep 100, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min |
Buffer | Gradient AmAc pH 3.0- 20-60 mM, 15 min |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Folpet |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsPrimesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsHPLC Separation of Folpet on Obelisc and Primesep Mixed-Mode Primesep B2 Column
August 24, 2015
Column | Primesep B2, 2.1 x 150 mm, 5 µm, 100 A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 4,5- 20-50 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 250 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Folpet |
Application Column
Primesep B2
Column Diameter: 2.1 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A