CAS Number | 5598-13-0 |
---|---|
Molecular Formula | C7H7Cl3NO3PS |
Molecular Weight | 322.520 |
InChI Key | HRBKVYFZANMGRE-UHFFFAOYSA-N |
LogP | 4.31 |
Synonyms |
|
Applications:
HPLC Separation of Pesticides on Newcrom B Column
February 3, 2020
Column | Newcrom B, 4.6×150 mm, 3 µm, 100A |
Mobile Phase | MeCN/H2O |
Buffer | Formic Acid |
Flow Rate | 1.0 ml/min |
Detection | UV, 260, 270 nm |
Class of Compounds | Hydrophobic, Herbicide, Pesticide |
Analyzing Compounds | Metalaxyl, Propoxur, Paclobutrazol, Abamectin, Propanil, Iprodione, Dursban, Pentachlorophenol, Fenvalerate |
Application Column
Newcrom B
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select optionsChlorpyrifos-methyl (Dursban)
Fenvalerate
Iprodione
Metalaxyl (UV)
Paclobutrazol
Pentachlorophenol
Propanil
Propoxur
HPLC Separation of 12 Pesticides on Newcrom B Column
January 24, 2020
Column | Newcrom B, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O |
Buffer | Formic Acid |
Flow Rate | 1.0 ml/min |
Detection | UV, 260 nm |
Class of Compounds | Hydrophobic, Herbicide, Pesticide |
Analyzing Compounds | 6-Benzylaminopurine, Metalaxyl, Prochloraz, Paclobutrazol, Procymidone, Propanil, Chlorothalonil, Abamectin, Bifenazate, Dursban, Pentachlorophenol, Fenvalerate |
Application Column
Newcrom B
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select optionsAbamectin
Bifenazate
Chlorothalonil
Chlorpyrifos-methyl (Dursban)
Fenvalerate
Metalaxyl (UV)
Paclobutrazol
Pentachlorophenol
Prochloraz
Procymidone
Propanil
HPLC Determination of Dursban on Newcrom B Column
January 6, 2020
Column | Newcrom B, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN/H2O – 60/40% |
Buffer | AmFm pH 3.0 – 20 mM |
Flow Rate | 1.0 ml/min |
Detection | UV, 280 nm |
Class of Compounds | Hydrophobic, Herbicide, Pesticide |
Analyzing Compounds | Chlorpyrifos-methyl (Dursban) |
Application Column
Newcrom B
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select optionsHPLC Retention of Chlorpyrifos-methyl on Primesep 100 and Obelisc R Mixed-Mode Columns
September 14, 2015
Chlorpyrifos-methyl, an organophosphate pesticide is considered a target pesticide by the EURL (European Union Reference Laboratory) for the EUPT-FF9 2015 a proficiency test for the analysis of a over a hundred pesticides. This compound was separated on two different mixed-mode columns, Primesep 100 and Obelisc R. Primesep 100 is a reverse phase column that contains embedded acidic ion-pairing groups, while Obelisc R retains with long hydrophobic chains and multiple ionic pairing groups on the surface. Method is LC/MS compatible and can be replicated to analyze dozens of other pesticides.
Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 25-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 3.0- 30-60 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 3.0- 20-60 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Column | Primesep 100, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 3.0- 20-60 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 270 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Chlorpyrifos-methyl |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsPrimesep 100
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsChlorpyrifos-methyl Separation Using Obelisc and Primesep Columns
August 24, 2015
Column | Primesep B2, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 4,5- 20-50 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 250 nm |
Column | Obelisc R, 2.1×150 mm, 5 µm, 100A |
Mobile Phase | Gradient MeCN – 10-70%, 15 min, 7 min hold |
Buffer | Gradient AmAc pH 4,5- 20-50 mM, 15 min, 7 min hold |
Flow Rate | 0.4 ml/min |
Detection | UV, 250 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Chlorpyrifos-methyl |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select optionsPrimesep B2
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsPrimesep C
The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.
Select optionsHPLC Analysis of Chlorpyrifos-methyl
August 10, 2015
Column | Obelisc R, 4.6×150 mm, 5 µm, 100A |
Mobile Phase | MeCN – 30% |
Buffer | AmFm pH 3.0- 20 mM |
Flow Rate | 1.0 ml/min |
Detection | UV, 250 nm |
Class of Compounds |
Insecticide, Herbicide, Fungicide, Hydrophobic, Ionizable |
Analyzing Compounds | Chlorpyrifos-methyl |
Application Column
Obelisc R
SIELC has developed the Obelisc™ columns, which are mixed-mode and utilize Liquid Separation Cell technology (LiSC™). These cost-effective columns are the first of their kind to be commercially available and can replace multiple HPLC columns, including reversed-phase (RP), AQ-type reversed-phase, polar-embedded group RP columns, normal-phase, cation-exchange, anion-exchange, ion-exclusion, and HILIC (Hydrophilic Interaction Liquid Chromatography) columns. By controlling just three orthogonal method parameters - buffer concentration, buffer pH, and organic modifier concentration - users can adjust the column properties with pinpoint precision to separate complex mixtures.
Select options