Oleic acid, monoester with propane-1,2-diol

Oleic acid, monoester with propane-1,2-diol structural formula

CAS Number1330-80-9
Molecular FormulaC21H40O3
Molecular Weight340.549
InChI KeyZVTDEEBSWIQAFJ-KHPPLWFESA-N
LogP7.37
Synonyms
  • Oleic acid, monoester with propane-1,2-diol
  • 2-Hydroxypropyl (9Z)-octadec-9-enoate
  • 9-Octadecenoic acid, 2-hydroxypropyl ester, (9Z)-
  • 1330-80-9
  • 9-Octadecenoic acid (9Z)-, monoester with 1,2-propanediol
  • (Z)-9-Octadecenoic acid monoester with 1,2-propanediol
  • 9-Octadecenoic acid (Z)-, monoester with 1,2-propanediol
  • 9-Octadecenoic acid, monoester with 1,2-propanediol, (Z)-
  • Acide oleique, monoester avec le propane-1,2-diol
  • acide oleique, monoester avec propane-1,2-diol
  • acido oleico, monoester con propano-1,2-diol
  • Emcol PO 50
  • Hydroxypropyl oleate
  • Nissan Nonion PO 100
  • Nofable PO 991
  • Nonion PO 100
  • Oelsaure, Monoester mit Propan-1,2-diol
  • Oleic acid, ester with 1,2-propanediol
  • Oleic acid, monoester with 1,2-propanediol
  • Propylene glycol monooleate
  • PROPYLENE GLYCOL OLEATE
  • Sunsoft 25O
  • Sunsoft 25OD
  • Sunsoft 25ODV
  • Sunsoft O 30
  • EINECS 215-549-3
  • UNII-F7946PIR36
  • 27213-39-4
  • 8034-37-5

Applications:

Separation of Oleic acid, monoester with propane-1,2-diol on Newcrom R1 HPLC column

February 16, 2018
Separation of Oleic acid, monoester with propane-1,2-diol on Newcrom C18 HPLC column

Oleic acid, monoester with propane-1,2-diol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Oleic acid, monoester with propane-1,2-diol
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.