Lypressin

Lypressin structural formula

CAS Number50-57-7
Molecular FormulaC46H65N13O12S2
Molecular Weight1056.230
InChI KeyBJFIDCADFRDPIO-DZCXQCEKSA-N
LogP-3.35
Synonyms
  • Lypressin
  • 1-{(4R,7S,10S,13S,16S,19R)-19-Amino-7-(2-amino-2-oxoethyl)-10-(3-amino-3-oxopropyl)-13-benzyl-16-[(4-hydroxyphenyl)methyl]-6,9,12,15,18-pentaoxo-1,2-dithia-5,8,11,14,17-pentaazacycloicosane-4-carbonyl}-L-prolyl-L-lysylglycinamide
  • Glycinamide, 1-[[(4R,7S,10S,13S,16S,19R)-19-amino-7-(2-amino-2-oxoethyl)-10-(3-amino-3-oxopropyl)-16-[(4-hydroxyphenyl)methyl]-6,9,12,15,18-pentaoxo-13-(phenylmethyl)-1,2-dithia-5,8,11,14,17-pentaazacycloeicos-4-yl]carbonyl]-L-prolyl-L-lysyl-
  • 50-57-7
  • [Lys8]-Vasopressin
  • Vasopressin, 8-L-lysine-
  • [8-Lysine]vasopressin
  • 1,2-Dithia-5,8,11,14,17-pentaazacycloeicosane-10-propionamide, 19-amino-4-[2-[[5-amino-1-[(carbamoylmethyl)carbamoyl]pentyl]carbamoyl]-1-pyrrolidinylcarbonyl]-13-benzyl-7-(carbamoylmethyl)-16-p-hydroxybenzyl-6,9,12,15,18-pentaoxo-
  • 3-(Phenylalanine)-8-lysine oxytocin
  • 8-L-Lysine vasopressin
  • Glycinamide, L-cysteinyl-L-tyrosyl-L-phenylalanyl-L-glutaminyl-L-asparaginyl-L-cysteinyl-L-prolyl-L-lysyl-, cyclic (1?6)-disulfide
  • lipresina
  • L-Lysine vasopressin
  • lypressine
  • Lysine pitressin
  • Lysine vasopressin
  • Lysine-ADH
  • Lysipressin
  • Lysopressin
  • Lysylvasopressin
  • Oxytocin, 3-(L-phenylalanine)-8-L-lysine-
  • Postacton
  • Syntopressin
  • Vasophysin
  • Vasopressin-8-lysine
  • BRN 4648365
  • EINECS 200-050-5
  • Lysine-vasopressin
  • (8-Lysine)vasopressin
  • Lipressina
  • Lypressinum
  • UNII-7CZF3L922Y

Applications:

Separation of Lypressin on Newcrom R1 HPLC column

May 16, 2018
Separation of Lypressin on Newcrom R1 HPLC column

Lypressin can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Lypressin
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.