HPLC Method for Labetalol on Primesep 200 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Labetalol
Labetalol is a medication used to treat high blood pressure (hypertension). It is a combined alpha- and beta-blocker, which means it works by blocking both alpha and beta receptors in the body.
Labetalol can be retained, and analyzed using a Primesep 200 mixed-mode stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water, acetonitrile (MeCN), and Formic Acid as a buffer. Detection is achieved using UV at 300 nm
You can find detailed UV spectra of Labetalol and information about its various lambda maxima by visiting the following link.
Column | Primesep 200, 2.1 x 100 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 40/60% |
Buffer | Formic Acid – 0.2% |
Flow Rate | 0.2 ml/min |
Detection | UV 300 nm, SIM + 329 |
Class of Compounds | Beta-blocker |
Analyzing Compounds | Labetalol |
Application Column
Primesep 200
Column Diameter: 2.1 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
LC MS Detection